4529609

Thermo Scientific™ Orion Star™ A326 pH/Dissolved Oxygen Portable Multiparameter Meter

Accurately measure pH, dissolved oxygen and temperature with our pH/DO/RDO portable meter for high performance in challenging field tests.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Outputs

USB, RS232

Accuracy (Barometer)

±6mmHg

Accuracy (pH)

±0.002

Accuracy (RDO)

±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L

Backlight Option

Yes, selectable

Battery Life

800 hr.

Calibration

pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature

Calibration Points

1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance

CE, TUV 3-1, FCC Class A

Data Points

5000 with date and time stamp

Display Type

LCD Graphic, Backlit

Measurement Modes

pH, mV, Relative mV, ORP with Temperature, Dissolved Oxygen (% Saturation), Dissolved Oxygen (mg/L with Temperature)

Range (mV)

±2000.0 mV

Resolution (pH)

0.1/0.01/0.001

Inputs

BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature)

Keypad

Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type

Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Methods

10 per channel with password protection

Percent Saturation Range (Polarographic DO)

0.0 to 600.0 % saturation

Percent Saturation Resolution (Polarographic DO)

0.1, 1 % saturation

Percent Saturation Relative Accuracy (Polarographic DO)

±2 % saturation or ±2% of reading whichever is greater

Power Supply

4 AA batteries (included) or universal AC adapter (sold separately)

Pressure Resolution

1mmHg

Range (Polarographic DO)

0.00 to 90.00mg/L

Range (Relative mV)

±2000.0 mV

Resolution (mV)

0.1mV

Resolution (RDO)

0.01, 0.1mg/L

Stability

Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature (English) Operating

41°F to 113°F (ambient)

Temperature Probe Calibration

1 point temperature offset calibration

Temperature Resolution

0.1°C, 0.1°F

Warranty

3 Year Meter

Weight (English)

1.2 lb.

AC Adapter

Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003)

Accuracy (mV)

±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Polarographic DO)

±0.2mg/L or ±2% of reading, whichever is greater

Alarm Output

High/low limit alarm, calibration due alarm

Barometric Pressure Correction

400 to 850mmHg, automatic using built-in barometer or manual entry

Battery Type

4 AA (included)

Calibration Modes

Water-saturated air, air-saturated water, manual (Winkler titration), zero point

Calibration Points (pH)

1 to 5

Data Management Details

Transfer single, range or all data points to printer or computer

Channels

2

IP Rating

IP 67

Percent Saturation Range Polarographic DO

0.0 to 600.0 % saturation

Range (pH)

-2.000 to 20.000

Temperature Range (Metric)

-5.0°C to +105.0°C

Isopotential Point

7.000pH

Languages

English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update

Memory

Non-volatile memory preserves data log, calibration log and meter settings

Model

Orion Star A326 pH/mV/RmV/ORP/RDO Optical/Dissolved Oxygen/Temperature Portable Meter

Percent Saturation Relative Accuracy (RDO)

±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation

Percent Saturation Range (RDO)

0.0 to 500.0 % saturation

Percent Saturation Resolution (RDO)

0.1, 1 % saturation

Pressure Range

400 to 850mmHg

Range (ORP)

±2000.0 mV

Range (RDO)

0.00 to 50.00mg/L

Relative Humidity Range

5 to 85 %, non-condensing

Resolution (Polarographic DO)

0.01, 0.1mg/L

Salinity Factor

0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity

Temperature Accuracy

±0.1°C

Temperature (Metric) Operating

5°C to 45°C (ambient)

Temperature Range (English)

22.0°F to 221.0° F

Temperature Selection

Manual or automatic with ATC temperature probe

Dimensions (L x W x H)

24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.)

Weight (Metric)

0.5 kg

Related Products

Img

Fischer Scientific

4529599

Reliably measure pH, dissolved oxyg...

Img

Fischer Scientific

13-645-566

--

Img

Fischer Scientific

13-645-548

--

Img

Fischer Scientific

13-645-550

--

Img

Fischer Scientific

13-645-568

--

Img

Fischer Scientific

4529340

Accurately monitor dissolved oxygen...

Img

Fischer Scientific

13-645-557

--

Img

Fischer Scientific

4529337

Reliably measure dissolved oxygen (...

Description

  • Get high accuracy and premium performance everywhere you need it with the Thermo Scientific™ Orion Star™ A326 pH/Dissolved Oxygen Portable Multiparameter Meter
  • This meter is designed for a wide range of pH, mV, ORP, dissolved oxygen and temperature testing and field applications
  • Evaluate samples in the most demanding locations using this waterproof meter with IP67-rated housing
  • Use the two meter channels to measure pH and dissolved oxygen simultaneously or view each channel separately
  • Log up to 5000 data point sets with time/date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer
  • Take your measurements at the source with our premium line of portable meters
  • The Thermo Scientific Orion Star A326 pH/RDO/DO Portable Meter offers an information-rich screen and user-friendly operation
  • This rugged, waterproof portable meter is ready to tackle the elements with you
  • Orion Star A326 pH/RDO/DO Portable Meters are designed to be easy-to-use, dependable field meters that offer advanced features and functions including a 5000 point date log with sample ID and user ID options, calibration and high/low limit alarms and password-protected measurement methods
  • Combined convenience with the benefits of a pH meter and dissolved oxygen meter in one easy-to-use system Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two Easily view individual measurements on a full screen display and quickly toggle to a split screen display to view multiple measurements simultaneously Perform up to a 5 point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values and calibration editing option that allows individual points to be fixed without a full recalibration Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation Capture your critical readings with measurement stability indicator and selectable read modes — Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals Data log collects and date/time stamps up to 5,000 measurement sets with optional sample ID and user ID Calibration log stores 10 most recent calibrations Non-volatile meter memory ensures your data and settings are protected, even with loss of power Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections Flexible power options with AA batteries or optional universal power adapter IP67-rated housing is waterproof for rugged field operation Meter kits include hard-sided field case and protective meter armor with electrode holders, adjustable wrist/belt strap and built-in meter stand Meters offer CE, TUV 3-in-1 and FCC Class A certifications 3-year replacement warranty Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Compare Similar Items

Show Difference

Img

Fischer Scientific

4529609

Accurately measure pH, dissolved ox...


Outputs:
USB, RS232

Accuracy (Barometer):
±6mmHg

Accuracy (pH):
±0.002

Accuracy (RDO):
±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L

Backlight Option:
Yes, selectable

Battery Life:
800 hr.

Calibration:
pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
5000 with date and time stamp

Display Type:
LCD Graphic, Backlit

Measurement Modes:
pH, mV, Relative mV, ORP with Temperature, Dissolved Oxygen (% Saturation), Dissolved Oxygen (mg/L with Temperature)

Range (mV):
±2000.0 mV

Resolution (pH):
0.1/0.01/0.001

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature)

Keypad:
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Methods:
10 per channel with password protection

Percent Saturation Range (Polarographic DO):
0.0 to 600.0 % saturation

Percent Saturation Resolution (Polarographic DO):
0.1, 1 % saturation

Percent Saturation Relative Accuracy (Polarographic DO):
±2 % saturation or ±2% of reading whichever is greater

Power Supply:
4 AA batteries (included) or universal AC adapter (sold separately)

Pressure Resolution:
1mmHg

Range (Polarographic DO):
0.00 to 90.00mg/L

Range (Relative mV):
±2000.0 mV

Resolution (mV):
0.1mV

Resolution (RDO):
0.01, 0.1mg/L

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Temperature Resolution:
0.1°C, 0.1°F

Warranty:
3 Year Meter

Weight (English):
1.2 lb.

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003)

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Polarographic DO):
±0.2mg/L or ±2% of reading, whichever is greater

Alarm Output:
High/low limit alarm, calibration due alarm

Barometric Pressure Correction:
400 to 850mmHg, automatic using built-in barometer or manual entry

Battery Type:
4 AA (included)

Calibration Modes:
Water-saturated air, air-saturated water, manual (Winkler titration), zero point

Calibration Points (pH):
1 to 5

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
2

IP Rating:
IP 67

Percent Saturation Range Polarographic DO:
0.0 to 600.0 % saturation

Range (pH):
-2.000 to 20.000

Temperature Range (Metric):
-5.0°C to +105.0°C

Isopotential Point:
7.000pH

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Star A326 pH/mV/RmV/ORP/RDO Optical/Dissolved Oxygen/Temperature Portable Meter

Percent Saturation Relative Accuracy (RDO):
±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation

Percent Saturation Range (RDO):
0.0 to 500.0 % saturation

Percent Saturation Resolution (RDO):
0.1, 1 % saturation

Pressure Range:
400 to 850mmHg

Range (ORP):
±2000.0 mV

Range (RDO):
0.00 to 50.00mg/L

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Polarographic DO):
0.01, 0.1mg/L

Salinity Factor:
0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity

Temperature Accuracy:
±0.1°C

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Range (English):
22.0°F to 221.0° F

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.)

Weight (Metric):
0.5 kg

Img

Fischer Scientific

4529612

Accurately measure pH, conductivity...


Outputs:
USB, RS232

Accuracy (Barometer):
__

Accuracy (pH):
±0.002

Accuracy (RDO):
__

Backlight Option:
Yes, selectable

Battery Life:
800 hr.

Calibration:
pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
5000 with date and time stamp

Display Type:
LCD Graphic, Backlit

Measurement Modes:
pH, mV, Relative mV, TDS, ORP with Temperature, Salinity, Conductivity, Resistivity with Temperature

Range (mV):
±2000.0 mV

Resolution (pH):
0.1/0.01/0.001

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe)

Keypad:
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Methods:
10 per channel with password protection

Percent Saturation Range (Polarographic DO):
__

Percent Saturation Resolution (Polarographic DO):
__

Percent Saturation Relative Accuracy (Polarographic DO):
__

Power Supply:
4 AA batteries (included) or universal AC adapter (sold separately)

Pressure Resolution:
__

Range (Polarographic DO):
__

Range (Relative mV):
±2000.0 mV

Resolution (mV):
0.1mV

Resolution (RDO):
__

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Temperature Resolution:
0.1°C, 0.1°F

Warranty:
3 Year Meter

Weight (English):
1.2 lb.

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003)

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Polarographic DO):
__

Alarm Output:
High/low limit alarm, calibration due alarm

Barometric Pressure Correction:
__

Battery Type:
4 AA (included)

Calibration Modes:
__

Calibration Points (pH):
1 to 5

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
2

IP Rating:
IP 67

Percent Saturation Range Polarographic DO:
__

Range (pH):
-2.000 to 20.000

Temperature Range (Metric):
-5.0°C to +105.0°C

Isopotential Point:
7.000pH

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Star A325 pH/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter

Percent Saturation Relative Accuracy (RDO):
__

Percent Saturation Range (RDO):
__

Percent Saturation Resolution (RDO):
__

Pressure Range:
__

Range (ORP):
±2000.0 mV

Range (RDO):
__

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Polarographic DO):
__

Salinity Factor:
__

Temperature Accuracy:
±0.1°C

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Range (English):
22.0°F to 221.0° F

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.)

Weight (Metric):
0.5 kg

Img

Fischer Scientific

4529615

Accurately measure pH, ion concentr...


Outputs:
USB, RS232

Accuracy (Barometer):
±6mmHg

Accuracy (pH):
±0.002

Accuracy (RDO):
±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L

Backlight Option:
Yes, selectable

Battery Life:
800 hr.

Calibration:
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
5000 with date and time stamp

Display Type:
LCD Graphic, Backlit

Measurement Modes:
pH, mV, Relative mV, TDS, ORP with Temperature, Salinity, Conductivity, Resistivity with Temperature

Range (mV):
±2000.0 mV

Resolution (pH):
0.1/0.01/0.001

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature)

Keypad:
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Methods:
10 per channel with password protection

Percent Saturation Range (Polarographic DO):
0.0 to 600.0 % saturation

Percent Saturation Resolution (Polarographic DO):
0.1, 1 % saturation

Percent Saturation Relative Accuracy (Polarographic DO):
±2 % saturation or ±2% of reading whichever is greater

Power Supply:
4 AA batteries (included) or universal AC adapter (sold separately)

Pressure Resolution:
1mmHg

Range (Polarographic DO):
0.00 to 90.00mg/L

Range (Relative mV):
±2000.0 mV

Resolution (mV):
0.1mV

Resolution (RDO):
0.01, 0.1mg/L

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Temperature Resolution:
0.1°C, 0.1°F

Warranty:
3 Year Meter

Weight (English):
1.2 lb.

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003)

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Polarographic DO):
±0.2mg/L or ±2% of reading, whichever is greater

Alarm Output:
High/low limit alarm, calibration due alarm

Barometric Pressure Correction:
400 to 850mmHg, automatic using built-in barometer or manual entry

Battery Type:
4 AA (included)

Calibration Modes:
Water-saturated air, air-saturated water, manual (Winkler titration), zero point

Calibration Points (pH):
1 to 5

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
3

IP Rating:
IP 67

Percent Saturation Range Polarographic DO:
0.0 to 600.0 % saturation

Range (pH):
-2.000 to 20.000

Temperature Range (Metric):
-5.0°C to +105.0°C

Isopotential Point:
7.000pH

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Star A329 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Portable Meter

Percent Saturation Relative Accuracy (RDO):
±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation

Percent Saturation Range (RDO):
0.0 to 500.0 % saturation

Percent Saturation Resolution (RDO):
0.1, 1 % saturation

Pressure Range:
400 to 850mmHg

Range (ORP):
±2000.0 mV

Range (RDO):
0.00 to 50.00mg/L

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Polarographic DO):
0.01, 0.1mg/L

Salinity Factor:
0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity

Temperature Accuracy:
±0.1°C

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Range (English):
22.0°F to 221.0° F

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.)

Weight (Metric):
0.5 kg

Img

Fischer Scientific

4529632

Get premium performance and ultimat...


Outputs:
USB, RS-232

Accuracy (Barometer):
__

Accuracy (pH):
±0.002

Accuracy (RDO):
__

Backlight Option:
Yes

Battery Life:
__

Calibration:
pH with calibration editing option, relative mV, ORP, LogR temperature and temperature

Calibration Points:
__

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
2000 with Date and Time Stamp

Display Type:
LCD, Color Graphic with User-Customizable Options

Measurement Modes:
pH with LogR Temperature, mV, Relative mV, ORP with Temperature

Range (mV):
__

Resolution (pH):
0.001, 0.01, 0.1

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe)

Keypad:
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic with Auto-Read, Timed and Single Shot Measure Modes; Manual

Methods:
10 per channel

Percent Saturation Range (Polarographic DO):
__

Percent Saturation Resolution (Polarographic DO):
__

Percent Saturation Relative Accuracy (Polarographic DO):
__

Power Supply:
Universal AC adapter (included)

Pressure Resolution:
__

Range (Polarographic DO):
__

Range (Relative mV):
±2000.0mV

Resolution (mV):
0.1mV

Resolution (RDO):
__

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration, 3 point LogR temperature calibration

Temperature Resolution:
__

Warranty:
__

Weight (English):
2.5 lb., modules add 0.5 lb. each

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)

Accuracy (mV):
±0.2 or ±0.05%, whichever is greater

Accuracy (Polarographic DO):
__

Alarm Output:
Set point alarm, high/low limit alarm, calibration due alarm

Barometric Pressure Correction:
__

Battery Type:
__

Calibration Modes:
__

Calibration Points (pH):
__

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
4 - customizable with modules

IP Rating:
IP-54

Percent Saturation Range Polarographic DO:
__

Range (pH):
-2 to 20

Temperature Range (Metric):
-5°C to +105°C

Isopotential Point:
7.000pH (adjustable)

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
__

Percent Saturation Relative Accuracy (RDO):
__

Percent Saturation Range (RDO):
__

Percent Saturation Resolution (RDO):
__

Pressure Range:
__

Range (ORP):
±2000.0mV

Range (RDO):
__

Relative Humidity Range:
5 to 85%, non-condensing

Resolution (Polarographic DO):
__

Salinity Factor:
__

Temperature Accuracy:
__

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Range (English):
22.0°F to 221.0°F

Temperature Selection:
Manual or automatic with ATC temperature probe, automatic with pH electrode using LogR mode

Dimensions (L x W x H):
__

Weight (Metric):
1.2 kg, modules add 0.2 kg each