CR9901006

Polygard® CR Cartridge Filter

pore size 100.0 μm, cartridge nominal length 10 in. (25 cm), Code 0 (2-222; O-rings)

Manufacturer: Millipore

Synonym(S): Polygard-CR Cartridge Filter 10 in. 100 μm Code 0 Silicone

Select a Size

Pack Size SKU Availability Price
6 PKG CR9901006-6-PKG In Stock ₹ 45,279.12

CR9901006 - 6 PKG

₹ 45,279.12

In Stock

Quantity

1

Base Price: ₹ 45,279.12

GST (18%): ₹ 8,150.242

Total Price: ₹ 53,429.362

material

polypropylene silicone seal

Quality Level

400

feature

hydrophilic

manufacturer/tradename

Polygard

parameter

4.8 bar max. differential pressure (70 psid) at 25 °C4.8 bar max. inlet pressure (70 psi) at 25 °C

cartridge nominal length

10 in. (25 cm)

diam.

7.0 cm (2.75 in.)

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

gravimetric extractables

≤50 mg

pore size

100.0 μm nominal pore size100.0 μm pore size

Related Products

Img

Millipore

CR9971006

pore size 100.0 μm, cartridge nomin...

Img

Millipore

CR1071006

pore size 10.0 μm, cartridge nomina...

Img

Millipore

CR9973006

pore size 100.0 μm, cartridge nomin...

Img

Millipore

CR0101006

pore size 1.0 μm, cartridge nominal...

Img

Millipore

CR1074006

pore size 10.0 μm, cartridge nomina...

Img

Millipore

CR9902006

pore size 100.0 μm, cartridge nomin...

Img

Millipore

CR9972006

pore size 100.0 μm, cartridge nomin...

Img

Millipore

CR1003006

pore size 10.0 μm, cartridge nomina...

Description

  • General description: The Polygard® CR Cartridge Filter products are nominally rated filters designed for particle removal applications in liquids and gases. The graded-density depth structure of Polygard-CR filter media provides maximum filtration capacity, a 100.0 μm pore size and the all-polypropylene construction offers low extractables levels and broad chemical compatibility.Polygard-CR cartridge filters provide high throughput with 4.8 bar max. differential pressure (70 psid) at 25 °C.Typical ApplicationsPolygard-CR high-efficiency cartridge filters, composed of graded density polypropylene media are widely used in the beverage industry for liquid and gas filtration applications to protect tighter filters.Regulatory CompliancePolygard® CR Cartridge Filters are designed, developed, and manufactured in accordance with a Quality Management System approved by an accredited registering body to an ISO 9000 Quality Systems Standard and are shipped with a Certificate of Quality. Each cartridge filter is supported by a Validation Guide for compliance with regulatory requirements.For traceability and easy identification, each filter is marked with identifying characteristics.Multiple Formats AvailablePolygard-CR product line offers a full range of filtration areas is available to suit varying application requirements. A variety of connection options are offered for easy adaptation to existing housings. These devices have been developed to minimize hold-up volume when evaluating multiple media configurations.
  • Preparation Note: Sanitization Protocol30 min with hot water @ 80 °C
  • Analysis Note: Gravimetric Extractables: after 24-h soak in water
  • Legal Information: POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

Show Difference

Img

Millipore

CR9901006

pore size 100.0 μm, cartridge nomin...


material:
polypropylene silicone seal

Quality Level:
400

feature:
hydrophilic

manufacturer/tradename:
Polygard

parameter:
4.8 bar max. differential pressure (70 psid) at 25 °C4.8 bar max. inlet pressure (70 psi) at 25 °C

cartridge nominal length:
10 in. (25 cm)

diam.:
7.0 cm (2.75 in.)

impurities:
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

gravimetric extractables:
≤50 mg

pore size:
100.0 μm nominal pore size100.0 μm pore size

Img

Millipore

CR9902006

pore size 100.0 μm, cartridge nomin...


material:
polypropylene silicone seal

Quality Level:
400

feature:
hydrophilic

manufacturer/tradename:
Polygard

parameter:
4.8 bar max. differential pressure (70 psid) at 25 °C4.8 bar max. inlet pressure (70 psi) at 25 °C

cartridge nominal length:
20 in. (50 cm)

diam.:
7.0 cm (2.75 in.)

impurities:
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

gravimetric extractables:
≤50 mg

pore size:
100.0 μm nominal pore size100.0 μm pore size

Img

Millipore

CR9971006

pore size 100.0 μm, cartridge nomin...


material:
polypropylene silicone seal

Quality Level:
400

feature:
hydrophilic

manufacturer/tradename:
Polygard

parameter:
4.8 bar max. differential pressure (70 psid) at 25 °C4.8 bar max. inlet pressure (70 psi) at 25 °C

cartridge nominal length:
10 in. (25 cm)

diam.:
7.0 cm (2.75 in.)

impurities:
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

gravimetric extractables:
≤50 mg

pore size:
100.0 μm nominal pore size100.0 μm pore size

Img

Millipore

CR9972006

pore size 100.0 μm, cartridge nomin...


material:
polypropylene silicone seal

Quality Level:
400

feature:
hydrophilic

manufacturer/tradename:
Polygard

parameter:
4.8 bar max. differential pressure (70 psid) at 25 °C4.8 bar max. inlet pressure (70 psi) at 25 °C

cartridge nominal length:
20 in. (50 cm)

diam.:
7.0 cm (2.75 in.)

impurities:
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

gravimetric extractables:
≤50 mg

pore size:
100.0 μm nominal pore size100.0 μm pore size