S72307

GENESYS 180 UV-Vis Spectrophotometer

Manufacturer: Thermo Scientific

The price for this product is unavailable. Please request a quote

Baseline Flatness

±0.002 A

Connections

Single USB-ADuplex USB-AExport data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, availablePrint via USB, Ethernet or Wi-Fi USB adaptor available

Detector Type

Dual Silicon Photodiodes

Dimensions (L x W x H)

35.5 x 38.5 x 19.5 cm

Wavelength Range

190 to 1100 nm

Electrical Requirements

External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz

Lamp Life

> 5 years typical, 3 years guaranteed

Optical Design

Double Beam

Photometric Range

–2A to +3.5A

Printer Included

Snap-on printer available

Stray Light

< 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2)

Wavelength Accuracy

±0.5 nm

Wavelength Repeatability

< ±0.2 nm

Compartments

8-position cell changer (standard)Also accommodates (optional):4-position cell changer (long path cells)Peltier thermostatted cell holder (20-60 °C)Sipper accessoryFiber optic probe coupler

Description

GENESYS 180 UV-Vis Spectrophotometer

Display

7 in. High Definition Color Touchscreen, Tiltable, 800 x 1280 pixels

Spectral Bandwidth

2 nm

Drift

(At 500 nm after 1 hour warmup) <0.0005 A/hr.

Keypad

Touchscreen

Noise

(RMS at 500nm 60 consecutive measurements)≤0.00020A at 0A at 260 and 500nm≤0.00030A at 1A at 260 and 500nm≤0.00040A at 2A at 260 and 500nm

Photometric Accuracy

±0.002 A at 0.5 A, ±0.004A at 1.0A, ±0.008 A at 2.0 A

Photometric Repeatability

±0.001 A at 1 A measured at 1.0 A at 546 nm

Scan Speed

Slow, medium and fast - up to 1600 nm/min.

Warranty

2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase

Wavelength Data Interval

0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm

Weight (Metric)

7.5 kg

Related Products

Img

Thermo Scientific™

14-385-354

--

Img

Thermo Scientific

S72306

--

Img

Thermo Scientific™

14-385-355

--

Img

Thermo Scientific

S72305

--

Img

Thermo Scientific™

14-385-355PM

--

Img

Thermo Scientific

S72304

--

Img

Thermo Scientific

S72303

--

Img

Thermo Scientific

S28454

--

Description

  • The GENESYS 180 UV-Vis Spectrophotometer provides double beam operation for laboratories requiring a reference cell position for applications such as kinetics
  • An 8-cell carousel comes standard for high-throughput applications
  • The spectrophotometer includes room-light resistance, allowing lid-open operation for improved speed and convenience
  • A full line of accessories, including automated cell changers and cell holders, sipper, and fiber optic probes for measurments outside of the sample compartment are designed to simplify sampling and accommodate high throughput measurements and temperature control
  • Features: Double Beam/Reference Cell 7-inch high-resolution touchscreen user interface Standard 8-position cell changer with switchable turret Onboard methods, reporting and data export Networking capable (Wi-Fi ready) Room light resistance for “open-lid” operation Sipper accessory Accommodates cells up to 100 mm pathlength 8-position cell changer with switchable turret (Optional) 4-position cell changer (long path cells) (Optional) Peltier-thermostatted single cell holder (20 °C - 60 °C) (Optional) Accessory for test-tubes up to 25 mm diameter and 150 mm height Designed for laboratories requiring double beam operation with a reference cell position

Compare Similar Items

Show Difference

Img

Thermo Scientific

S72307

--


Baseline Flatness:
±0.002 A

Connections:
Single USB-ADuplex USB-AExport data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, availablePrint via USB, Ethernet or Wi-Fi USB adaptor available

Detector Type:
Dual Silicon Photodiodes

Dimensions (L x W x H):
35.5 x 38.5 x 19.5 cm

Wavelength Range:
190 to 1100 nm

Electrical Requirements:
External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/240 V, 50/60 Hz

Lamp Life:
> 5 years typical, 3 years guaranteed

Optical Design:
Double Beam

Photometric Range:
–2A to +3.5A

Printer Included:
Snap-on printer available

Stray Light:
< 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2)

Wavelength Accuracy:
±0.5 nm

Wavelength Repeatability:
< ±0.2 nm

Compartments:
8-position cell changer (standard)Also accommodates (optional):4-position cell changer (long path cells)Peltier thermostatted cell holder (20-60 °C)Sipper accessoryFiber optic probe coupler

Description:
GENESYS 180 UV-Vis Spectrophotometer

Display:
7 in. High Definition Color Touchscreen, Tiltable, 800 x 1280 pixels

Spectral Bandwidth:
2 nm

Drift:
(At 500 nm after 1 hour warmup) <0.0005 A/hr.

Keypad:
Touchscreen

Noise:
(RMS at 500nm 60 consecutive measurements)≤0.00020A at 0A at 260 and 500nm≤0.00030A at 1A at 260 and 500nm≤0.00040A at 2A at 260 and 500nm

Photometric Accuracy:
±0.002 A at 0.5 A, ±0.004A at 1.0A, ±0.008 A at 2.0 A

Photometric Repeatability:
±0.001 A at 1 A measured at 1.0 A at 546 nm

Scan Speed:
Slow, medium and fast - up to 1600 nm/min.

Warranty:
2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase

Wavelength Data Interval:
0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm

Weight (Metric):
7.5 kg

Img

Bel-Art™ SP Scienceware™

S72309

--


Baseline Flatness:
__

Connections:
__

Detector Type:
__

Dimensions (L x W x H):
__

Wavelength Range:
__

Electrical Requirements:
__

Lamp Life:
__

Optical Design:
__

Photometric Range:
__

Printer Included:
__

Stray Light:
__

Wavelength Accuracy:
__

Wavelength Repeatability:
__

Compartments:
__

Description:
__

Display:
__

Spectral Bandwidth:
__

Drift:
__

Keypad:
__

Noise:
__

Photometric Accuracy:
__

Photometric Repeatability:
__

Scan Speed:
__

Warranty:
__

Wavelength Data Interval:
__

Weight (Metric):
__

Img

Fischer Scientific

S72310

--


Baseline Flatness:
__

Connections:
__

Detector Type:
__

Dimensions (L x W x H):
__

Wavelength Range:
__

Electrical Requirements:
__

Lamp Life:
__

Optical Design:
__

Photometric Range:
__

Printer Included:
__

Stray Light:
__

Wavelength Accuracy:
__

Wavelength Repeatability:
__

Compartments:
__

Description:
__

Display:
__

Spectral Bandwidth:
__

Drift:
__

Keypad:
__

Noise:
__

Photometric Accuracy:
__

Photometric Repeatability:
__

Scan Speed:
__

Warranty:
__

Wavelength Data Interval:
__

Weight (Metric):
__

Img

Fischer Scientific

S72311

--


Baseline Flatness:
__

Connections:
__

Detector Type:
__

Dimensions (L x W x H):
__

Wavelength Range:
__

Electrical Requirements:
__

Lamp Life:
__

Optical Design:
__

Photometric Range:
__

Printer Included:
__

Stray Light:
__

Wavelength Accuracy:
__

Wavelength Repeatability:
__

Compartments:
__

Description:
__

Display:
__

Spectral Bandwidth:
__

Drift:
__

Keypad:
__

Noise:
__

Photometric Accuracy:
__

Photometric Repeatability:
__

Scan Speed:
__

Warranty:
__

Wavelength Data Interval:
__

Weight (Metric):
__