09-034-201INS

Thermo Scientific™ Barnstead™ GenPure™ xCAD Plus Ultrapure Water Purification System, UV (Includes Installation)

Manufacturer: Thermo Scientific™

Select a Size

Pack Size SKU Availability Price
Each of 1 09-034-201INS-Each-of-1 In Stock ₹ 13,65,537.60

09-034-201INS - Each of 1

₹ 13,65,537.60

In Stock

Quantity

1

Base Price: ₹ 13,65,537.60

GST (18%): ₹ 2,45,796.768

Total Price: ₹ 16,11,334.368

Conductivity

0.055μS/cm

Bacterial Content

<0.01 CFU/mL

Feed Water Monitoring

Integrated

Resistivity

18.2 Mohm.cm at 25°C

Model

Barnstead GenPure xCAD Plus UV (wall version)

Particles >0.2µM/mL

<1

Temperature Range (Metric)

2°C to 35°C

Width (Metric)

372 mm

Height (Metric)

615 mm

Depth (Metric)

330 mm

Voltage

90/240 V

Description

Barnstead GenPure xCAD Plus UV (wall version)

Feedwater Connector

3/4 in.

Flow Rate

Up to 2 L/min.

Total Organic Carbon

1 to 5 ppb

Operating Pressure

0.1 to 6 bar

Power Consumption

0.1 kW

Width (English)

14.6 in.

Height (English)

24 in.

Depth (English)

13 in.

Electrical Requirements

90/240 V 50/60 Hz

Frequency

50/60 Hz

Related Products

Img

Thermo Scientific™

10-451-209INS

--

Img

Thermo Scientific™

10-451-210BB

--

Img

Thermo Scientific™

10-451-205BB

--

Img

Thermo Scientific™

10-451-216INS

--

Img

Thermo Scientific™

10-451-216BB

--

Img

Thermo Scientific™

10-451-213BB

--

Img

Thermo Scientific™

10-451-201PKG

--

Img

Thermo Scientific™

10-451-203PKG

--

Description

  • All GenPure systems exceed international standards ASTM Type I, ISO 3696 Grade 1, ASTM D1193 and CLSI-CLRW
  • xCAD (Extended Control and Dispenser): System provides more flexibility for ultrapure water dispensing with an action radius of 32″ (80cm)
  • Ergonomic dispensing arm provides precise volume dosing at the press of a button
  • Flexible dispenser offers positions including turned, height adjusted or extended toward your vessel
  • One-of-a-kind design provides access to all system controls at your fingertips
  • Simultaneously dispense from up to three dispensers: Each system ships with a single xCAD Plus remote dispenser
  • For increased flexibility, add one or two more xCAD Plus dispensers
  • Integrated feed water monitoring: Additional measuring cell monitors feed water conductivity
  • If the quality of the feed water drops below the set value, a fault message will immediately be displayed
  • Online TOC measurement with UV intensity monitoring (available on systems with optional TOC only): Real-time TOC monitoring offers continual measurement of organic substances present in the water
  • Continuous monitoring of UV intensity removes the risk of false TOC values due to diminished UV intensity
  • Fault message alerts user when the UV lamp intensity is no longer sufficient for accurate TOC measurements
  • UV Photo-oxidation 185/254 nm: High performance UV assembly reliably reduces the content of microorganisms and their metabolites
  • UV oxidation also reduces organic compounds in the water to ultra-low levels
  • Leak detection: An error message is displayed when internal leaks are detected
  • Ready to use: Feed water pressure switch, wall bracket, UV lamp, ultrapure cartridge, sterile filter, all are included in one part number
  • Measurement of conductivity/resistivity: Conductivity cells are carefully calibrated prior to each measurement via built-in reference resistance with cell constants at 0.01cm -1
  • Temperature measurements are made by a platinum chip sensor with ± 0.1°C accuracy
  • Quick-connect cartridge replacement: Aquastop quick-connect capability enables cartridge replacement within seconds even mid-operation
  • Exact dosing: Electronic dosing yields fully automatic volume control of 0.01-65 L with <2% accuracy
  • GLP-compliant documentation: Real-time clock and code-protected operating system prevents unauthorized changes to system settings
  • RS-232 interface with adjustable send-interval offers safe data transfer of all measured data, faults, date and time to a PC computer or log printer
  • Digital microprocessor control automatically monitors and stores faults from the last four weeks
  • USP-compliant conductivity measurement with temperature compensation can be switched on or off.

Compare Similar Items

Show Difference

Img

Thermo Scientific™

09-034-201INS

--


Conductivity:
0.055μS/cm

Bacterial Content:
<0.01 CFU/mL

Feed Water Monitoring:
Integrated

Resistivity:
18.2 Mohm.cm at 25°C

Model:
Barnstead GenPure xCAD Plus UV (wall version)

Particles >0.2µM/mL:
<1

Temperature Range (Metric):
2°C to 35°C

Width (Metric):
372 mm

Height (Metric):
615 mm

Depth (Metric):
330 mm

Voltage:
90/240 V

Description:
Barnstead GenPure xCAD Plus UV (wall version)

Feedwater Connector:
3/4 in.

Flow Rate:
Up to 2 L/min.

Total Organic Carbon:
1 to 5 ppb

Operating Pressure:
0.1 to 6 bar

Power Consumption:
0.1 kW

Width (English):
14.6 in.

Height (English):
24 in.

Depth (English):
13 in.

Electrical Requirements:
90/240 V 50/60 Hz

Frequency:
50/60 Hz

Img

Fischer Scientific

09-034-202

--


Conductivity:
__

Bacterial Content:
__

Feed Water Monitoring:
__

Resistivity:
__

Model:
Solaris Small Open Air Shaker

Particles >0.2µM/mL:
__

Temperature Range (Metric):
5°C to 60°C

Width (Metric):
__

Height (Metric):
__

Depth (Metric):
__

Voltage:
100/240 V

Description:
__

Feedwater Connector:
__

Flow Rate:
__

Total Organic Carbon:
__

Operating Pressure:
__

Power Consumption:
__

Width (English):
__

Height (English):
__

Depth (English):
__

Electrical Requirements:
100/240 V, 50/60 Hz

Frequency:
__

Img

Thermo Scientific™

09-034-202PM

--


Conductivity:
__

Bacterial Content:
__

Feed Water Monitoring:
__

Resistivity:
__

Model:
Solaris 2000

Particles >0.2µM/mL:
__

Temperature Range (Metric):
__

Width (Metric):
__

Height (Metric):
__

Depth (Metric):
__

Voltage:
__

Description:
__

Feedwater Connector:
__

Flow Rate:
__

Total Organic Carbon:
__

Operating Pressure:
__

Power Consumption:
__

Width (English):
__

Height (English):
__

Depth (English):
__

Electrical Requirements:
100/240 V, 50/60 Hz

Frequency:
__

Img

Fischer Scientific

09-034-203

--


Conductivity:
__

Bacterial Content:
__

Feed Water Monitoring:
__

Resistivity:
__

Model:
Solaris Large Open Air Shaker

Particles >0.2µM/mL:
__

Temperature Range (Metric):
5°C to 60°C

Width (Metric):
__

Height (Metric):
__

Depth (Metric):
__

Voltage:
100/240 V

Description:
__

Feedwater Connector:
__

Flow Rate:
__

Total Organic Carbon:
__

Operating Pressure:
__

Power Consumption:
__

Width (English):
__

Height (English):
__

Depth (English):
__

Electrical Requirements:
100/240 V, 50/60 Hz

Frequency:
__