ZIX7003T0

MilliporeSigma™ Milli-Q™ IX 7003 Water Purification System

Manufacturer: MilliporeSigma™

Select a Size

Pack Size SKU Availability Price
Each of 1 ZIX7003T0-Each-of-1 In Stock ₹ 10,21,389.61

ZIX7003T0 - Each of 1

₹ 10,21,389.61

In Stock

Quantity

1

Base Price: ₹ 10,21,389.61

GST (18%): ₹ 1,83,850.13

Total Price: ₹ 12,05,239.74

Bacterial Content

≤10 CFU/L

Feed Water Monitoring

Up to 2 L/min. from POD

Flow Rate

3 L/hr. (Milli-Q™ IX 7003), 5 L/hr. (Milli-Q™ IX 7005), 10 L/hr. (Milli-Q™ IX 7010), 15 L/hr. (Milli-Q™ IX 7015)

Resistivity

>5 Mohm.cm

Total Organic Carbon

<30 ppb

Daily Output

3 L/hr. (Milli-Q™ IX 7003), 5 L/hr. (Milli-Q™ IX 7005), 10 L/hr. (Milli-Q™ IX 7010), 15 L/hr. (Milli-Q™ IX 7015)

Feedwater Source

Potable Tap

Product Water Type

Potable Tap

TOC Monitor with UV Intensity Monitoring

<30 ppb

Related Products

Img

MilliporeSigma™

ZIX7005T0

--

Img

MilliporeSigma™

ZIX7010T0

--

Img

MilliporeSigma™

ZIX7015T0

--

Img

Fischer Scientific

ZIQ7003T0

--

Img

Fischer Scientific

ZIQ7005T0

--

Img

Fischer Scientific

ZIX7010P0

--

Img

Fischer Scientific

ZIX7015P0

--

Img

Fischer Scientific

ZIX7003P0

--

Description

  • Description The Milli-Q™ IX 7003 has been designed in a compact, ergonomic, mercury-free and intelligent way to deliver high quality pure water
  • The system features three separate and distinct components: Milli-Q™ production unit offers flexible installation and a more simplified maintenance
  • The Milli-Q™ IQ Storage Tank and Top Tank is the optimal solution to protect pure water
  • The new E-POD™ point-of-delivery unit provides pure (Type 2) water through its large, intuitive touch screen
  • Up to two E-POD™ dispensers can be with each production unit at different locations in the laboratory
  • Pure (Type 2) water product allows to perform many critical and general lab applications: Microbiology culture media preparation, staining solutions for histology and cytology, immunohistochemistry (IHC), electrophoresis gel and buffers, western blotting, immunoassays (ELISA, RIA), drug dissolution testing, biological oxygen demand (BOD), chemical oxygen demand (COD), UV/Vis spectroscopy, titration, etc
  • Sample preparation (dilution, extraction...), buffer and reagent preparation, glassware rinsing, etc
  • Feeding laboratory instruments like autoclaves, dishwashers, weathering & stability test chambers, clinical analyzers and slide stainers, hydrogen generators, and ultrapure water systems (e.g
  • Milli-Q™ IQ 7000 system) DIGITAL SERVICES SIMPLIFY SYSTEM CARE AND ASSURE PRODUCTIVITY MyMilli-Q™ Remote Care is a unique online monitoring and service feature that provides: Remote access to your system and its data Automatic notifications, by email or SMS, in case of an alert or alarm Faster service with remote diagnostics and repair possible Simplified data management and advanced traceability that eases audit and accreditation processes Note: A complete water purification system is comprised of multiple components including the purification unit, consumables, and in some cases, dispensers, tanks, and other accessories, which should be included in your sales quotation
  • Please contact your Fisher Scientific Representative or MilliporeSigma Lab Water Solutions Specialist to receive a comprehensive quote prior to ordering.

Compare Similar Items

Show Difference

Img

MilliporeSigma™

ZIX7003T0

--


Bacterial Content:
≤10 CFU/L

Feed Water Monitoring:
Up to 2 L/min. from POD

Flow Rate:
3 L/hr. (Milli-Q™ IX 7003), 5 L/hr. (Milli-Q™ IX 7005), 10 L/hr. (Milli-Q™ IX 7010), 15 L/hr. (Milli-Q™ IX 7015)

Resistivity:
>5 Mohm.cm

Total Organic Carbon:
<30 ppb

Daily Output:
3 L/hr. (Milli-Q™ IX 7003), 5 L/hr. (Milli-Q™ IX 7005), 10 L/hr. (Milli-Q™ IX 7010), 15 L/hr. (Milli-Q™ IX 7015)

Feedwater Source:
Potable Tap

Product Water Type:
Potable Tap

TOC Monitor with UV Intensity Monitoring:
<30 ppb

Img

Fischer Scientific

ZIX7005P0

--


Bacterial Content:
≤10 CFU/L

Feed Water Monitoring:
Pretreated Water Using Electrodeionization (EDI), Deionization (DI), Reverse osmosis (RO), or Distillation Technologies

Flow Rate:
5 L/hr.

Resistivity:
__

Total Organic Carbon:
≤30 ppb

Daily Output:
__

Feedwater Source:
Potable Tap

Product Water Type:
__

TOC Monitor with UV Intensity Monitoring:
__

Img

MilliporeSigma™

ZIX7005T0

--


Bacterial Content:
≤10 CFU/L

Feed Water Monitoring:
Up to 2 L/min. from POD

Flow Rate:
3 L/hr. (Milli-Q™ IX 7003), 5 L/hr. (Milli-Q™ IX 7005), 10 L/hr. (Milli-Q™ IX 7010), 15 L/hr. (Milli-Q™ IX 7015)

Resistivity:
>5 Mohm.cm

Total Organic Carbon:
<30 ppb

Daily Output:
3 L/hr. (Milli-Q™ IX 7003), 5 L/hr. (Milli-Q™ IX 7005), 10 L/hr. (Milli-Q™ IX 7010), 15 L/hr. (Milli-Q™ IX 7015)

Feedwater Source:
Potable Tap

Product Water Type:
Potable Tap

TOC Monitor with UV Intensity Monitoring:
<30 ppb

Img

Fischer Scientific

ZIX7010P0

--


Bacterial Content:
≤10 CFU/L

Feed Water Monitoring:
Pretreated Water Using Electrodeionization (EDI), Deionization (DI), Reverse osmosis (RO), or Distillation Technologies

Flow Rate:
10 L/hr.

Resistivity:
__

Total Organic Carbon:
≤30 ppb

Daily Output:
__

Feedwater Source:
Potable Tap

Product Water Type:
__

TOC Monitor with UV Intensity Monitoring: