IB31001S

Invitrogen™ iBlot™ 3 Starter Kit, NC

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Pack of 3 IB31001S-Pack-of-3 In Stock ₹ 3,90,153.60

IB31001S - Pack of 3

₹ 3,90,153.60

In Stock

Quantity

1

Base Price: ₹ 3,90,153.60

GST (18%): ₹ 70,227.648

Total Price: ₹ 4,60,381.248

Content And Storage

• iBlot 3 Gel Transfer Device• Western Blot Roller• iBlot 3 Transfer Stacks, midi, nitrocellulose (2 boxes, 20 stacks)Store at room temperature.

For Use With (Equipment)

iBlot 3 Transfer Stacks

Membrane Compatibility

Nitrocellulose, PVDF

Product Line

iBlot 3

Throughput

2 Midi or 4 Mini Gels

Green Features

Less waste, sustainable packaging, sustainable disposal

Shipping Condition

Approved for shipment at Room Temperature or on Wet Ice

For Use With (Application)

Western Blot

Gel Compatibility

Mini- or Midi-sized: Bis-Tris Gels, Tricine Gels, Tris-Acetate Gels, and Tris-Glycine Gels

Mode of Transfer

Dry

Running Time

∼3 to 10 min.

Type

Starter Kit

Quantity

1 Kit

Warranty

Standard, 1-year warranty

Related Products

Img

Fischer Scientific

IB31002S

--

Img

Fischer Scientific

A56728

--

Img

Fischer Scientific

A56729

--

Img

Invitrogen™

IB31001SLF1

--

Img

Invitrogen™

IB31001SLF2

--

Img

Fischer Scientific

IB31001

--

Img

Fischer Scientific

A56727

--

Img

Invitrogen™

IB21001S

--

Description

  • The iBlot 3 Starter Kit includes the iBlot 3 Western Blot Transfer Device and two boxes of iBlot 3 Transfer Stacks, Midi, NC (nitrocellulose)—everything needed to perform a rapid dry-transfer of proteins from a gel to a membrane
  • iBlot 3 Western Blot Transfer Device The iBlot 3 Western Blot Transfer Device is a dry transfer device that performs western blotting transfer efficiently and reliably in as few as three minutes and without the need for liquid buffers
  • The iBlot 3 system is compatible with both nitrocellulose and polyvinylidene difluoride (PVDF) membranes and offers equivalent or better performance compared with traditional wet-transfer methods in a fraction of the time
  • The iBlot 3 Western Blot Transfer Device is an integral part of the iBlot dry blotting system, which consists of the transfer device and consumable transfer stacks that contain the required buffers and transfer membrane (nitrocellulose or PVDF)
  • iBlot 3 Western Blot Transfer Device features include: Complete protein transfer in as few as three minutes High detection sensitivity and even, consistent protein transfer Two independently controlled transfer stations capable of transferring up to two midi or four mini blots Built-in adjustable cooling to ensure consistent transfer temperature Pre-programed transfer methods optimized for low, high, and broad molecular weight ranges Ability to create custom programs A simple, user-friendly interface How the iBlot dry blotting system works Buffer ion reservoirs are incorporated into the gel matrix of transfer stacks instead of buffer tanks or soaked filter papers
  • The high density of ions in the gel matrix enables rapid protein transfer
  • During blotting, the copper anode does not generate oxygen gas as a result of water electrolysis, reducing blot distortion (conventional protein transfer techniques, including wet, semi-wet, and semi-dry, use inert electrodes that generate oxygen)
  • With the iBlot dry blotting system, transfer time is reduced by the shortened distance between electrodes, high field strength, and high current
  • Trapped air bubbles, often created during the manual preparation of the blotting sandwich layers, are easy to avoid due to our unique de-bubbling design that promotes even and complete transfer
  • With the iBlot 3 system, there is no need to prepare buffers or clean up after blotting
  • The total preparation and run time is normally less than ten minutes per blot.

Compare Similar Items

Show Difference

Img

Fischer Scientific

IB31001S

--


Content And Storage:
• iBlot 3 Gel Transfer Device• Western Blot Roller• iBlot 3 Transfer Stacks, midi, nitrocellulose (2 boxes, 20 stacks)Store at room temperature.

For Use With (Equipment):
iBlot 3 Transfer Stacks

Membrane Compatibility:
Nitrocellulose, PVDF

Product Line:
iBlot 3

Throughput:
2 Midi or 4 Mini Gels

Green Features:
Less waste, sustainable packaging, sustainable disposal

Shipping Condition:
Approved for shipment at Room Temperature or on Wet Ice

For Use With (Application):
Western Blot

Gel Compatibility:
Mini- or Midi-sized: Bis-Tris Gels, Tricine Gels, Tris-Acetate Gels, and Tris-Glycine Gels

Mode of Transfer:
Dry

Running Time:
∼3 to 10 min.

Type:
Starter Kit

Quantity:
1 Kit

Warranty:
Standard, 1-year warranty

Img

Invitrogen™

IB31001SLF1

--


Content And Storage:
• iBlot 3 Gel Transfer Device• Western Blot Roller• iBlot 3 Transfer Stacks, midi, nitrocellulose• iBind Western Device• iBind Cards• iBind Solution Kit• SuperSignal West Pico Plus Chemiluminescent Substrate

For Use With (Equipment):
__

Membrane Compatibility:
Nitrocellulose, PVDF

Product Line:
iBlot 3, iBind

Throughput:
__

Green Features:
Less waste, Sustainable packaging, Sustainable disposal

Shipping Condition:
Approved for shipment at Room Temperature or on Wet Ice

For Use With (Application):
Western Blot

Gel Compatibility:
Mini- or Midi-sized: Bis-Tris Gels, Tricine Gels, Tris-Acetate Gels, and Tris-Glycine Gels

Mode of Transfer:
Dry

Running Time:
__

Type:
Starter Kit

Quantity:
1 kit

Warranty:
__

Img

Invitrogen™

IB31001SLF2

--


Content And Storage:
• iBlot 3 Gel Transfer Device• Western Blot Roller• iBlot 3 Transfer Stacks, midi, nitrocellulose• iBind Flex Western Device• iBind Flex Cards• iBind Flex Solution Kit• SuperSignal West Pico Plus Chemiluminescent Substrate

For Use With (Equipment):
__

Membrane Compatibility:
Nitrocellulose, PVDF

Product Line:
iBlot 3, iBind

Throughput:
__

Green Features:
Less waste, Sustainable packaging, Sustainable disposal

Shipping Condition:
Approved for shipment at Room Temperature or on Wet Ice

For Use With (Application):
Western Blot

Gel Compatibility:
Mini- or Midi-sized: Bis-Tris Gels, Tricine Gels, Tris-Acetate Gels, and Tris-Glycine Gels

Mode of Transfer:
Dry

Running Time:
__

Type:
Starter Kit

Quantity:
1 kit

Warranty:
__

Img

Fischer Scientific

IB31002S

--


Content And Storage:
• iBlot 3 Gel Transfer Device• Western Blot Roller• iBlot 3 Transfer Stacks, midi, PVDF (2 boxes, 20 stacks)Store at room temperature.

For Use With (Equipment):
iBlot 3 Transfer Stacks

Membrane Compatibility:
Nitrocellulose, PVDF

Product Line:
iBlot 3

Throughput:
2 Midi or 4 Mini Gels

Green Features:
Less waste, Sustainable packaging, Sustainable disposal

Shipping Condition:
Approved for shipment at Room Temperature or on Wet Ice

For Use With (Application):
Western Blot

Gel Compatibility:
Mini- or Midi-sized: Bis-Tris Gels, Tricine Gels, Tris-Acetate Gels, and Tris-Glycine Gels

Mode of Transfer:
Dry

Running Time:
∼3 to 10 min.

Type:
Starter kit

Quantity:
__

Warranty:
Standard, 1-year warranty included