4924897

Invitrogen™ Amplex™ Red and Amplex™ UltraRed Reagents

The Amplex Red and UltraRed reagents are fluorogenic substrates for peroxidase. These highly sensitive and stable probes react with H2O2in the presence of HRP for solution-based assays and ELISAs. Amplex UltraRed is a brighter version of Amplex Red with an improved pH range and sensitivity.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Content And Storage

Store in freezer (-5°C to -30°C).

For Use With (Application)

Hydrogen Peroxidase Assay

Product Type

Red Hydrogen Peroxide

Product Line

Amplex™

Substrate

HRP (Horseradish Peroxidase) Substrate

Detection Method

Fluorescence

For Use With (Equipment)

Fluorometer, Microplate Reader

Form

Solid

Shipping Condition

Room Temperature

Validated Application

Cell Analysis

Related Products

Img

Fischer Scientific

A12222

--

Img

Fischer Scientific

A22177

--

Img

Fischer Scientific

A36006

--

Img

Fischer Scientific

7238536

Detect apoptosis in cell extracts a...

Img

Fischer Scientific

E13184

--

Img

Fischer Scientific

4922886

Visible light-excitable fura-2 anal...

Img

Fischer Scientific

F1241

--

Img

Fischer Scientific

7075899

Fluo-3, AM, Calcium Indicator...

Description

  • The Amplex Red and Amplex UltraRed reagents are highly sensitive and stable fluorescent probes for the detection of hydrogen peroxide (H 2 O 2 ) and ideal fluorogenic substrates for peroxidase
  • These reagents can be used for solution-based assays to detect the activity of H 2 O 2 released from biological samples or with HRP-based ELISA applications
  • The Amplex UltraRed reagent is an improved version of Amplex Red that is brighter and more sensitive to peroxidase with less pH sensitivity compared to the Amplex Red reagent
  • In the presence of horseradish peroxidase (HRP), the Amplex Red and UltraRed reagents react in a 1:1 stoichiometry with H 2 O 2 to produce highly fluorescent, strongly absorbing resorufin (ex/em ∼570/585 nm) or Amplex UltroxRed (ex/em ∼568/581 nm), respectively
  • These oxidized reaction products have a broad red emission with little interference from blue and green autofluorescence found in most biological samples
  • Because H 2 O 2 is produced in many different enzymatic reactions, the Amplex Red and UltraRed reagents coupled with HRP can be used to detect the activity of many different enzymes
  • These reagents are also used to detect H 2 O 2 released from biological samples, including cells and isolated mitochondria
  • Features of the Amplex Red reagent: • Sensitive and fast detection of HRP activity or H 2 O 2 for solution-based assays and ELISAs • Detection of H 2 O 2 produced in many different enzymatic reactions • Measurement with either fluorescence or absorbance, permitting either fluorogenic or chromogenic detection The Amplex Red reagent has been used to develop a variety of novel fluorogenic and chromogenic assays for enzymes that produce hydrogen peroxide
  • When coupled with added horseradish peroxidase, these assays that generate H 2 O 2 permit the ultrasensitive quantitation of a diverse assortment of analytes, including glucose, galactose, cholesterol, glutamic acid, xanthine (or hypoxanthine), uric acid, choline, and acetylcholine
  • The Amplex UltraRed reagent offers brighter fluorescence and enhanced sensitivity on a per-mole basis in peroxidase or peroxidase-coupled enzyme assays compared to Amplex Red
  • The Amplex UltraRed reagent is also less sensitive to acidic pH and exhibits improved stability in the presence of H 2 O 2 or thiols such as dithiothreitol (DTT)
  • For HRP-based ELISA applications, this results in at least two-fold greater sensitivity compared to Amplex Red
  • Benefits of the Amplex UltraRed reagent over Amplex Red: • Brighter signals and enhanced sensitivity for HRP activity and H 2 O 2 • Less sensitive to acidic pH • Improved stability in the presence of H 2 O 2 or thiols such as DTT The Amplex Red and Amplex UltraRed reaction products resorufin and Amplex UltroxRed have high extinction coefficients so they can be measured either fluorometrically or spectrophotometrically with absorbance at ∼560 nm, providing flexibility in detection of H 2 O 2 , various enzyme assays, and HRP-based ELISAs
  • Order Info Shipping Condition: Room Temperature

Compare Similar Items

Show Difference

Img

Fischer Scientific

4924897

The Amplex Red and UltraRed reagent...


Content And Storage:
Store in freezer (-5°C to -30°C).

For Use With (Application):
Hydrogen Peroxidase Assay

Product Type:
Red Hydrogen Peroxide

Product Line:
Amplex™

Substrate:
HRP (Horseradish Peroxidase) Substrate

Detection Method:
Fluorescence

For Use With (Equipment):
Fluorometer, Microplate Reader

Form:
Solid

Shipping Condition:
Room Temperature

Validated Application:
Cell Analysis

Img

Fischer Scientific

4924916

For detection and quantification of...


Content And Storage:
__

For Use With (Application):
__

Product Type:
__

Product Line:
__

Substrate:
__

Detection Method:
__

For Use With (Equipment):
__

Form:
__

Shipping Condition:
__

Validated Application:
__

Img

Fischer Scientific

4924919

Free radical sensor...


Content And Storage:
__

For Use With (Application):
__

Product Type:
__

Product Line:
__

Substrate:
__

Detection Method:
__

For Use With (Equipment):
__

Form:
__

Shipping Condition:
__

Validated Application:
__

Img

Fischer Scientific

4924945

Dulbecco's phosphate-buffered salin...


Content And Storage:
Storage conditions:15°C to 30°CShipping conditions:Room temperatureShelf life:36 months from date of manufacture

For Use With (Application):
Mammalian Cell Culture

Product Type:
DPBS

Product Line:
Gibco™

Substrate:
__

Detection Method:
__

For Use With (Equipment):
__

Form:
Liquid

Shipping Condition:
Room Temperature

Validated Application:
__