BTX452043

BTX™ Gemini SC Electroporation Generator Only

Manufacturer: BTX™

Select a Size

Pack Size SKU Availability Price
Each of 1 BTX452043-Each-of-1 In Stock ₹ 14,38,178.04

BTX452043 - Each of 1

₹ 14,38,178.04

In Stock

Quantity

1

Base Price: ₹ 14,38,178.04

GST (18%): ₹ 2,58,872.047

Total Price: ₹ 16,97,050.087

For Use With (Application)

Universal Electroporation of All Cell Typesin Cuvettes

Frequency

50/60 Hz

Product Type

Electroporator

Voltage Range (HV Mode)

510 to 3000 V (in 10 V steps)

Description

Gemini SC Electroporation Generator Only

Certifications/Compliance

CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric)

33 cm

Height (Metric)

21.6 cm

Life Span

2 year warranty

Pulse Number Range

Exponential Decay Wave 1 pulse/sample, Square Wave 1 to 10 pulses/sample

Operating Temperature (Metric)

4°C to 40°C

Wattage

35 W (idle), 350 W (pulsing)

Weight (Metric)

7.3 kg

Width (Metric)

28.6 cm

Sterility

Non-sterile

Capacitance (LV Mode)

3775 μF (Square Wave), 25 to 3275 μF in 25 μF Steps (Exponential Decay Wave)

Charging Time

<7 sec. (LV), <4 sec. (HV)

Pulse Form

Exponential Decay Wave, Square Wave

For Use With (Equipment)

SC Cuvette Safety Dome

Product Line

BTX Electroporation

Voltage

10 to 3000 V

Voltage Range (LV Mode)

10 to 500 V (in 5 V steps)

Display

Color Touchscreen

Depth (English)

13 in.

Height (English)

8.5 in.

Includes

Generator Only

Operating Temperature (English)

40°F to 104°F

Pulse Length Range

Exponential Decay Wave Time constant 0.5 ms to 3.275 ms; Square Wave pulse length 50 ms to 100 ms

Relative Humidity

80% max. when operating at 25°C

Weight (English)

16 lb.

Width (English)

11.25 in.

Electrical Requirements

100 to 240 VAC

Capacitance (HV Mode)

85 μF (Square Wave), 10, 25, 35, 50, 60, 75, 85 μF (Exponential Decay Wave)

Connection Type

Banana Cables

Interface

Touchscreen

High-throughput Compatibility

No

Related Products

Img

BTX™

BTX452041

--

Img

BTX™

BTX452040

--

Img

BTX™

BTX452044

--

Img

BTX™

BTX450652

--

Img

BTX™

BTX452051

--

Img

BTX™

BTX450654

--

Img

BTX™

BTX450651

--

Img

BTX™

BTX450655

--

Description

  • Features: Universal electroporation - transfects cells in vitro, in vivo, in ovo and adherent forms Transformation of bacteria, yeast, microorganisms; Transfection of mammalian cells and tissues Multiple pulsing capabilities in both square and exponential decay waveforms (X2 systems) Preset protocols - includes the most common eukaryotic and prokaryotic cell types Square and exponential decay wave options Large touchscreen interface User-defined protocols - unlimited ability to add and modify protocols Safety - displays resistance measurements for each pulse with three layers of arc protection Connector: Positive and Negative 4 mm Banana Cables Certifications CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE Warranty and Services 2 Year

Compare Similar Items

Show Difference

Img

BTX™

BTX452043

--


For Use With (Application):
Universal Electroporation of All Cell Typesin Cuvettes

Frequency:
50/60 Hz

Product Type:
Electroporator

Voltage Range (HV Mode):
510 to 3000 V (in 10 V steps)

Description:
Gemini SC Electroporation Generator Only

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
21.6 cm

Life Span:
2 year warranty

Pulse Number Range:
Exponential Decay Wave 1 pulse/sample, Square Wave 1 to 10 pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
7.3 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF (Square Wave), 25 to 3275 μF in 25 μF Steps (Exponential Decay Wave)

Charging Time:
<7 sec. (LV), <4 sec. (HV)

Pulse Form:
Exponential Decay Wave, Square Wave

For Use With (Equipment):
SC Cuvette Safety Dome

Product Line:
BTX Electroporation

Voltage:
10 to 3000 V

Voltage Range (LV Mode):
10 to 500 V (in 5 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
8.5 in.

Includes:
Generator Only

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
Exponential Decay Wave Time constant 0.5 ms to 3.275 ms; Square Wave pulse length 50 ms to 100 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
16 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF (Square Wave), 10, 25, 35, 50, 60, 75, 85 μF (Exponential Decay Wave)

Connection Type:
Banana Cables

Interface:
Touchscreen

High-throughput Compatibility:
No

Img

BTX™

BTX452044

--


For Use With (Application):
Universal Electroporation of All Sample Types

Frequency:
50/60 Hz

Product Type:
Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 5 V steps)

Description:
Gemini X2 High Throughput System, 96-well with HT-200

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
21.6 cm

Life Span:
2 year warranty

Pulse Number Range:
Exponential Decay Wave 1 to 2 pulses/sample, Square Wave 1 to 99 pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
7.3 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF (Square Wave), 25 to 3275 μF in 25 μF Steps (Exponential Decay Wave)

Charging Time:
<7 sec. (LV), <4 sec. (HV)

Pulse Form:
Exponential Decay Wave, Square Wave

For Use With (Equipment):
Cuvette Safety Dome, Cuvette Safety Stand, HT-100 High-Throughput Electroporation Plate Handler, HT-200 Automatic High-Throughput Electroporation Plate Handler, BTX Specialtyin-Vivo Electrodes

Product Line:
BTX Electroporation

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
8.5 in.

Includes:
Generator, Safety Dome, Cuvettes, Cuvette Rack, Plate Handler, Gap Plates

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
Exponential Decay Wave Time constant 0.5 ms to 133.875 ms; Square Wave pulse length 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
16 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF (Square Wave), 10, 25, 35, 50, 60, 75, 85 μF (Exponential Decay Wave)

Connection Type:
Banana Cables

Interface:
Touchscreen

High-throughput Compatibility:
Yes

Img

BTX™

BTX452045

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ Cell Fusion System

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

Pulse Form:
AC Sine Wave, DC Square Wave

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Line:
__

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, Microslides, Meander Fusion Chamber, Flat Electrode/Divergent Field, Electrode Adapter, Connection Cable, Safety Stand, Cuvettes with Rack

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Interface:
Touch Screen Display, Footswitch

High-throughput Compatibility:
__

Img

BTX™

BTX452047

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ Embryo Manipulation System

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

Pulse Form:
AC Sine Wave, DC Square Wave

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Line:
__

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, Microslides, Round Wire, Rectangular Wire, Micrograbber Adapter Cables

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Interface:
Touch Screen Display, Footswitch

High-throughput Compatibility:
No