BTX452047

BTX™ ECM™ 2001+ Embryo Manipulation System

Manufacturer: BTX™

Select a Size

Pack Size SKU Availability Price
Each of 1 BTX452047-Each-of-1 In Stock ₹ 1,48,76,830.56

BTX452047 - Each of 1

₹ 1,48,76,830.56

In Stock

Quantity

1

Base Price: ₹ 1,48,76,830.56

GST (18%): ₹ 26,77,829.501

Total Price: ₹ 1,75,54,660.061

For Use With (Application)

Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency

50/60 Hz

Voltage

5 to 3000 V

Voltage Range (LV Mode)

5 to 500 V (in 1 V steps)

Display

Color Touchscreen

Depth (English)

13 in.

Height (English)

13 in.

Includes

ECM 2001+ Generator, Microslides, Round Wire, Rectangular Wire, Micrograbber Adapter Cables

Operating Temperature (English)

40°F to 104°F

Pulse Length Range

AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity

80% max. when operating at 25°C

Weight (English)

22 lb.

Width (English)

11.25 in.

Electrical Requirements

100 to 240 VAC

Capacitance (HV Mode)

85 μF

Connection Type

Output Cable

Interface

Touch Screen Display, Footswitch

High-throughput Compatibility

No

For Use With (Equipment)

Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Type

Electrofusion generator and Electroporator

Voltage Range (HV Mode)

505 to 3000 V (in 1 V steps)

Description

ECM 2001+ Embryo Manipulation System

Certifications/Compliance

CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric)

33 cm

Height (Metric)

33 cm

Life Span

2 year warranty

Pulse Number Range

1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric)

4°C to 40°C

Wattage

35 W (idle), 350 W (pulsing)

Weight (Metric)

10.0 kg

Width (Metric)

28.6 cm

Sterility

Non-sterile

Capacitance (LV Mode)

3775 μF

Charging Time

<7 sec.

Pulse Form

AC Sine Wave, DC Square Wave

Related Products

Img

BTX™

BTX452045

--

Img

BTX™

BTX452049

--

Img

BTX™

BTX452050

--

Img

BTX™

BTX452048

--

Img

BTX™

BTX450662

--

Img

BTX™

BTX450667

--

Img

BTX™

BTX450666

--

Img

BTX™

BTX450664

--

Description

  • Features: AC waveform of 0.2 - 2.0 MHz AC sinewave and DC square wave options Square wave mammalian electroporation capabilities Wide range of voltages from 5V to 3000V Pre-set protocols - includes most common cell fusion applications User-defined protocols - unlimited ability to add and modify protocols Advanced programmability - combine up to 19 AC steps pre- and post- DC fusion step Simple to use, large 7-inch touchscreen interface Includes: ECM 2001+ Generator, Microslides, Round Wire (0.5 mm gap, 1.0 mm gap), Rectangular Wire (3.2 mm gap), Micrograbber Adapter Cables Connector: Output Cable with Positive and Negative 4 mm Banana Jacks Certifications CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE Warranty and Services 2 Year

Compare Similar Items

Show Difference

Img

BTX™

BTX452047

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, Microslides, Round Wire, Rectangular Wire, Micrograbber Adapter Cables

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Interface:
Touch Screen Display, Footswitch

High-throughput Compatibility:
No

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ Embryo Manipulation System

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

Pulse Form:
AC Sine Wave, DC Square Wave

Img

BTX™

BTX452048

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, 2 ml Coaxial Optimization Chamber (470030), 9 ml Coaxial Production Chamber, Female/Female Adapter Set, Cytofusion Medium C (500 ml)

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Interface:
Touch Screen Display, Footswitch

High-throughput Compatibility:
__

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ Hybridoma System

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

Pulse Form:
AC Sine Wave, DC Square Wave

Img

BTX™

BTX452049

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, 5 ft. High Voltage Output Cable, F/F Adapter Set

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Interface:
__

High-throughput Compatibility:
__

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ Generator Only

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

Pulse Form:
AC Sine Wave, DC Square Wave

Img

BTX™

BTX452050

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, 630B Safety Stand, Cuvettes, Cuvette Rack, Enhancer 3000 Probe, Enhancer Interface Box, Oscilloscope and Cables

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Interface:
Touch Screen Display, Footswitch

High-throughput Compatibility:
No

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ System with Monitoring, for Cuvettes

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

Pulse Form:
AC Sine Wave, DC Square Wave