BTX452049

BTX™ ECM™ 2001+ Generator Only

Manufacturer: BTX™

Select a Size

Pack Size SKU Availability Price
Each of 1 BTX452049-Each-of-1 In Stock ₹ 46,90,912.56

BTX452049 - Each of 1

₹ 46,90,912.56

In Stock

Quantity

1

Base Price: ₹ 46,90,912.56

GST (18%): ₹ 8,44,364.261

Total Price: ₹ 55,35,276.821

For Use With (Application)

Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency

50/60 Hz

Product Type

Electrofusion generator and Electroporator

Voltage Range (HV Mode)

505 to 3000 V (in 1 V steps)

Description

ECM 2001+ Generator Only

Certifications/Compliance

CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric)

33 cm

Height (Metric)

33 cm

Life Span

2 year warranty

Pulse Number Range

1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric)

4°C to 40°C

Wattage

35 W (idle), 350 W (pulsing)

Weight (Metric)

10.0 kg

Width (Metric)

28.6 cm

Sterility

Non-sterile

Capacitance (LV Mode)

3775 μF

Charging Time

<7 sec.

For Use With (Equipment)

Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Line

BTX Electroporation and Electrofusion

Voltage

5 to 3000 V

Voltage Range (LV Mode)

5 to 500 V (in 1 V steps)

Display

Color Touchscreen

Depth (English)

13 in.

Height (English)

13 in.

Includes

ECM 2001+ Generator, 5 ft. High Voltage Output Cable, F/F Adapter Set

Operating Temperature (English)

40°F to 104°F

Pulse Length Range

AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity

80% max. when operating at 25°C

Weight (English)

22 lb.

Width (English)

11.25 in.

Electrical Requirements

100 to 240 VAC

Capacitance (HV Mode)

85 μF

Connection Type

Output Cable

Pulse Form

AC Sine Wave, DC Square Wave

Related Products

Img

BTX™

BTX452047

--

Img

BTX™

BTX452045

--

Img

BTX™

BTX452048

--

Img

BTX™

BTX452050

--

Img

BTX™

BTX450662

--

Img

BTX™

BTX450667

--

Img

BTX™

BTX450666

--

Img

BTX™

BTX450664

--

Description

  • Features: AC waveform of 0.2 - 2.0 MHz AC sinewave and DC square wave options Square wave mammalian electroporation capabilities Wide range of voltages from 5V to 3000V Pre-set protocols - includes most common cell fusion applications User-defined protocols - unlimited ability to add and modify protocols Advanced programmability - combine up to 19 AC steps pre- and post- DC fusion step Simple to use, large 7-inch touchscreen interface Includes: ECM 2001+ Generator, 5 ft
  • High Voltage Output Cable, F/F Adapter Set Connector: Output Cable with Positive and Negative 4 mm Banana Jacks Certifications CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE Warranty and Services 2 Year

Compare Similar Items

Show Difference

Img

BTX™

BTX452049

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ Generator Only

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Line:
BTX Electroporation and Electrofusion

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, 5 ft. High Voltage Output Cable, F/F Adapter Set

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Pulse Form:
AC Sine Wave, DC Square Wave

Img

BTX™

BTX452050

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ System with Monitoring, for Cuvettes

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Line:
__

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, 630B Safety Stand, Cuvettes, Cuvette Rack, Enhancer 3000 Probe, Enhancer Interface Box, Oscilloscope and Cables

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Pulse Form:
AC Sine Wave, DC Square Wave

Img

BTX™

BTX452051

--


For Use With (Application):
Transformation of Bacteria, Yeast, Microorganisms; Transfection of Some Mammalian Cell Types

Frequency:
50/60 Hz

Product Type:
Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 5 V steps)

Description:
ECM 630 Electroporation System Complete, with Safety Dome

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
21.6 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 2 Pulses/Sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
7.3 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
25 to 3275 μF (in 25 μF steps)

Charging Time:
<7 sec. (LV), <4 sec. (HV)

For Use With (Equipment):
Cuvette Safety Dome, Cuvette Safety Stand, HT-100 High-Throughput Electroporation Plate Handler, HT-200 Automatic High-Throughput Electroporation Plate Handler

Product Line:
BTX Electroporation

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
8.5 in.

Includes:
ECM 630 Generator, Safety Dome, Cuvettes, Cuvette Rack 660

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
Exponential Decay Wave Time constant 0.5 ms to 133.875 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
16 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
10, 25, 35, 50, 60, 75, 85 μF

Connection Type:
Banana Cables

Pulse Form:
Exponential Decay Wave

Img

BTX™

BTX452052

--


For Use With (Application):
Transformation of Bacteria, Yeast, Microorganisms; Transfection of Some Mammalian Cell Types

Frequency:
50/60 Hz

Product Type:
Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 5 V steps)

Description:
__

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
21.6 cm

Life Span:
__

Pulse Number Range:
1 to 99 Pulses/Sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
7.3 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec. (LV), <4 sec. (HV)

For Use With (Equipment):
Cuvette Safety Dome, Cuvette Safety Stand, HT-100 High-Throughput Electroporation Plate Handler, HT-200 Automatic High-Throughput Electroporation Plate Handler, BTX Specialtyin-Vivo Electrodes

Product Line:
BTX Electroporation

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
8.5 in.

Includes:
Generator, Safety Dome, Cuvettes 1 mm, 2 mm, 4 mm (30 Pk., 10 Ea.) and Cuvette Rack 660

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
16 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Banana Cables

Pulse Form:
Square Wave