BTX452050

BTX™ ECM™ 2001+ Electroporation System Complete, for Cuvettes with Monitoring

Manufacturer: BTX™

The price for this product is unavailable. Please request a quote

For Use With (Application)

Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency

50/60 Hz

Voltage

5 to 3000 V

Voltage Range (LV Mode)

5 to 500 V (in 1 V steps)

Display

Color Touchscreen

Depth (English)

13 in.

Height (English)

13 in.

Includes

ECM 2001+ Generator, 630B Safety Stand, Cuvettes, Cuvette Rack, Enhancer 3000 Probe, Enhancer Interface Box, Oscilloscope and Cables

Operating Temperature (English)

40°F to 104°F

Pulse Length Range

AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity

80% max. when operating at 25°C

Weight (English)

22 lb.

Width (English)

11.25 in.

Electrical Requirements

100 to 240 VAC

Capacitance (HV Mode)

85 μF

Connection Type

Output Cable

Interface

Touch Screen Display, Footswitch

High-throughput Compatibility

No

For Use With (Equipment)

Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Type

Electrofusion generator and Electroporator

Voltage Range (HV Mode)

505 to 3000 V (in 1 V steps)

Description

ECM 2001+ System with Monitoring, for Cuvettes

Certifications/Compliance

CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric)

33 cm

Height (Metric)

33 cm

Life Span

2 year warranty

Pulse Number Range

1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric)

4°C to 40°C

Wattage

35 W (idle), 350 W (pulsing)

Weight (Metric)

10.0 kg

Width (Metric)

28.6 cm

Sterility

Non-sterile

Capacitance (LV Mode)

3775 μF

Charging Time

<7 sec.

Pulse Form

AC Sine Wave, DC Square Wave

Related Products

Img

BTX™

BTX452045

--

Img

BTX™

BTX452047

--

Img

BTX™

BTX452048

--

Img

BTX™

BTX452049

--

Img

BTX™

BTX450667

--

Img

BTX™

BTX450662

--

Img

BTX™

BTX450661

--

Img

BTX™

BTX450655

--

Description

  • Features: AC waveform of 0.2 - 2.0 MHz AC sinewave and DC square wave options Square wave mammalian electroporation capabilities Wide range of voltages from 5V to 3000V Pre-set protocols - includes most common cell fusion applications User-defined protocols - unlimited ability to add and modify protocols Advanced programmability - combine up to 19 AC steps pre- and post- DC fusion step Simple to use, large 7-inch touchscreen interface Includes: ECM 2001+ Generator, 630B Safety Stand, Cuvettes 1 mm, 2 mm, 4 mm, pkg
  • of 30 (10 each), Cuvette Rack, Enhancer 3000 Probe, Enhancer Interface Box, Oscilloscope and Cables Connector: Output Cable with Positive and Negative 4 mm Banana Jacks Certifications CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE Warranty and Services 2 Year

Compare Similar Items

Show Difference

Img

BTX™

BTX452050

--


For Use With (Application):
Electrofusion of All Cell Types; Hybridoma Generation; Nuclear Transfer; Embryo Manipulation; Transfection of Mammalian Cells and Tissues; Transformation of Some Bacteria and Microorganisms

Frequency:
50/60 Hz

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
13 in.

Includes:
ECM 2001+ Generator, 630B Safety Stand, Cuvettes, Cuvette Rack, Enhancer 3000 Probe, Enhancer Interface Box, Oscilloscope and Cables

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
AC Sinewave: 1 to 99 s, DC Square wave: 10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
22 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Output Cable

Interface:
Touch Screen Display, Footswitch

High-throughput Compatibility:
No

For Use With (Equipment):
Coaxial Chambers, Microslides, Meander Fusion Chamber, Flat Electrode, Cuvette Safety Dome, BTX Specialtyin-Vivo Electrodes

Product Type:
Electrofusion generator and Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 1 V steps)

Description:
ECM 2001+ System with Monitoring, for Cuvettes

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
33 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 19 AC sinewave pulses, 1 to 99 DC square wave pulses/sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
10.0 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec.

Pulse Form:
AC Sine Wave, DC Square Wave

Img

BTX™

BTX452051

--


For Use With (Application):
Transformation of Bacteria, Yeast, Microorganisms; Transfection of Some Mammalian Cell Types

Frequency:
50/60 Hz

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
8.5 in.

Includes:
ECM 630 Generator, Safety Dome, Cuvettes, Cuvette Rack 660

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
Exponential Decay Wave Time constant 0.5 ms to 133.875 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
16 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
10, 25, 35, 50, 60, 75, 85 μF

Connection Type:
Banana Cables

Interface:
Touchscreen

High-throughput Compatibility:
Yes

For Use With (Equipment):
Cuvette Safety Dome, Cuvette Safety Stand, HT-100 High-Throughput Electroporation Plate Handler, HT-200 Automatic High-Throughput Electroporation Plate Handler

Product Type:
Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 5 V steps)

Description:
ECM 630 Electroporation System Complete, with Safety Dome

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
21.6 cm

Life Span:
2 year warranty

Pulse Number Range:
1 to 2 Pulses/Sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
7.3 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
25 to 3275 μF (in 25 μF steps)

Charging Time:
<7 sec. (LV), <4 sec. (HV)

Pulse Form:
Exponential Decay Wave

Img

BTX™

BTX452052

--


For Use With (Application):
Transformation of Bacteria, Yeast, Microorganisms; Transfection of Some Mammalian Cell Types

Frequency:
50/60 Hz

Voltage:
5 to 3000 V

Voltage Range (LV Mode):
5 to 500 V (in 1 V steps)

Display:
Color Touchscreen

Depth (English):
13 in.

Height (English):
8.5 in.

Includes:
Generator, Safety Dome, Cuvettes 1 mm, 2 mm, 4 mm (30 Pk., 10 Ea.) and Cuvette Rack 660

Operating Temperature (English):
40°F to 104°F

Pulse Length Range:
10 ms to 999 ms

Relative Humidity:
80% max. when operating at 25°C

Weight (English):
16 lb.

Width (English):
11.25 in.

Electrical Requirements:
100 to 240 VAC

Capacitance (HV Mode):
85 μF

Connection Type:
Banana Cables

Interface:
Touchscreen

High-throughput Compatibility:
Yes

For Use With (Equipment):
Cuvette Safety Dome, Cuvette Safety Stand, HT-100 High-Throughput Electroporation Plate Handler, HT-200 Automatic High-Throughput Electroporation Plate Handler, BTX Specialtyin-Vivo Electrodes

Product Type:
Electroporator

Voltage Range (HV Mode):
505 to 3000 V (in 5 V steps)

Description:
__

Certifications/Compliance:
CE Marking, ETL Marking (UL, CSA), CB Scheme, EU RoHS, WEEE

Depth (Metric):
33 cm

Height (Metric):
21.6 cm

Life Span:
__

Pulse Number Range:
1 to 99 Pulses/Sample

Operating Temperature (Metric):
4°C to 40°C

Wattage:
35 W (idle), 350 W (pulsing)

Weight (Metric):
7.3 kg

Width (Metric):
28.6 cm

Sterility:
Non-sterile

Capacitance (LV Mode):
3775 μF

Charging Time:
<7 sec. (LV), <4 sec. (HV)

Pulse Form:
Square Wave

Img

Fischer Scientific

BTX452059

--


For Use With (Application):
Embryo Manipulation, Nuclear Transfer, Cell Fusion, Hybridoma Production, Plant Protoplast Fusion

Frequency:
__

Voltage:
__

Voltage Range (LV Mode):
__

Display:
__

Depth (English):
__

Height (English):
__

Includes:
Electrode Only

Operating Temperature (English):
__

Pulse Length Range:
__

Relative Humidity:
__

Weight (English):
__

Width (English):
__

Electrical Requirements:
__

Capacitance (HV Mode):
__

Connection Type:
Banana Plug to Micrograbber

Interface:
__

High-throughput Compatibility:
__

For Use With (Equipment):
ECM™ 830, ECM™ 2001, ECM 2001+, Gemini X2 Generator

Product Type:
Electroporation accessory

Voltage Range (HV Mode):
__

Description:
Oocyte Petri Electrode, Platinum, 15 mm, 1mm gap

Certifications/Compliance:
__

Depth (Metric):
__

Height (Metric):
__

Life Span:
__

Pulse Number Range:
__

Operating Temperature (Metric):
__

Wattage:
__

Weight (Metric):
__

Width (Metric):
__

Sterility:
Non-sterile

Capacitance (LV Mode):
__

Charging Time:
__

Pulse Form:
AC Sine Wave, DC Square Wave