CTGR71TP1

Aervent® 0.2 µm, Cartridge

pore size 0.2 μm, cartridge nominal length 10 in. (25 cm), Code 7

Manufacturer: Millipore

Synonym(S): Aervent CTGR Cartridge Filter 10 in. 0.2 µm Code 7

Select a Size

Pack Size SKU Availability Price
1 EA CTGR71TP1-1-EA In Stock ₹ 53,378.08

CTGR71TP1 - 1 EA

₹ 53,378.08

In Stock

Quantity

1

Base Price: ₹ 53,378.08

GST (18%): ₹ 9,608.054

Total Price: ₹ 62,986.134

material

PTFE polypropylene polypropylene supportsilicone seal

Quality Level

400

sterility

non-sterile

Sterilization Compatibility

steam-in-place compatible

product line

Aervent®

feature

hydrophobic

manufacturer/tradename

Aervent®

parameter

≤24 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)1.7 bar max. inlet pressure (25 psi) at 80 °C1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

technique(s)

gas filtration: suitable

L

10 in.

Related Products

Img

Millipore

CTGR75S01

pore size 0.2 μm, cartridge nominal...

Img

Millipore

KTGRA10HH1

inlet connection diam. 9/16 in., Op...

Img

Millipore

MCGB20S02

filtration area 1000 cm2, hydrophob...

Img

Millipore

KVGLA02NN3

Opticap® XL 2, inlet connection dia...

Img

Millipore

KVGLA02TH3

Opticap® XL 2, inlet connection dia...

Description

  • General description: Device Configuration: Cartridge
  • Features and Benefits: Rated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.
  • Packaging: Double Easy-Open bag
  • Quality: Retains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²
  • Preparation Note: Sterilization Method150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
  • Analysis Note: Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Other Notes: Directions for UseOrganism Retention: MicroorganismMode of Action: Filtration (size exclusion)Application: BioProcessingIntended Use: Reduction or removal of microorganism/bioburdenInstructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection GuideStorage Statement: Store in dry locationDisposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
  • Legal Information: AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

Show Difference

Img

Millipore

CTGR71TP1

pore size 0.2 μm, cartridge nominal...


material:
PTFE polypropylene polypropylene supportsilicone seal

Quality Level:
400

sterility:
non-sterile

Sterilization Compatibility:
steam-in-place compatible

product line:
Aervent®

feature:
hydrophobic

manufacturer/tradename:
Aervent®

parameter:
≤24 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)1.7 bar max. inlet pressure (25 psi) at 80 °C1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

technique(s):
gas filtration: suitable

L:
10 in.

Img

Millipore

CTGR75S01

pore size 0.2 μm, cartridge nominal...


material:
PTFE polypropylene polypropylene supportsilicone seal

Quality Level:
400

sterility:
non-sterile

Sterilization Compatibility:
steam-in-place compatible

product line:
Aervent®

feature:
hydrophobic

manufacturer/tradename:
Aervent®

parameter:
≤12 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)1.7 bar max. inlet pressure (25 psi) at 80 °C1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

technique(s):
gas filtration: suitable

L:
5 in.

Img

Millipore

CTGR75S01

pore size 0.2 μm, cartridge nominal...


material:
PTFE polypropylene polypropylene supportsilicone seal

Quality Level:
400

sterility:
non-sterile

Sterilization Compatibility:
steam-in-place compatible

product line:
Aervent®

feature:
hydrophobic

manufacturer/tradename:
Aervent®

parameter:
≤12 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)1.7 bar max. inlet pressure (25 psi) at 80 °C1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

technique(s):
gas filtration: suitable

L:
5 in.

Img

Sigma Aldrich

CTI1

Transgene Integration in the Human ...


material:
__

Quality Level:
200

sterility:
__

Sterilization Compatibility:
__

product line:
CompoZr®

feature:
__

manufacturer/tradename:
__

parameter:
__

technique(s):
__

L: