13-642-781

Thermo Scientific™ Orion™ Dual Star™ pH, ISE, mV, ORP and Temperature Dual Channel Benchtop Meter

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each 13-642-781-Each In Stock ₹ 2,75,901.05

13-642-781 - Each

₹ 2,75,901.05

In Stock

Quantity

1

Base Price: ₹ 2,75,901.05

GST (18%): ₹ 49,662.189

Total Price: ₹ 3,25,563.239

AC Adapter

Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)

Outputs

USB, RS232

Accuracy (pH)

±0.002

Advanced ISE Functions

Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit

Backlight Option

Yes, adjustable

Calibration Points

1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance

CE, TUV 3-1, FCC Class A

Data Points

1000 with date and time stamp

Calibration Points (ISE)

2 to 6

Measurement Modes

pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature

Range (mV)

±1999.9 mV

Resolution (ISE)

0.0001 minimum, 1 to 3 significant digits (user selectable)

Temperature (Metric) Range

-5.0°C to +105.0°C

Includes

Dual Star pH/ISE dual channel meter, 8102BNUWP ROSS Ultra glass-body pH electrode, 927007MD Orion stainless steel ATC probe, electrode stand, universal power adapter, literature, computer interface cable and meter test certificate

Isopotential Point

7.000 pH (adjustable), 1.000 ISE (adjustable)

Languages

English, Spanish, French, Italian and German

Memory

Non-volatile memory preserves data log, calibration log and meter settings

Model

Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter

Probe Type

pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)

Range (Relative mV)

±1999.9 mV

Resolution (mV)

0.1 mV

Stability

Smart Stability and Smart Averaging

Temperature (Metric) Operating

5°C to 45°C (ambient)

Temperature Selection

Manual or automatic with ATC temperature probe

Dimensions (L x W x H)

24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)

Weight (Metric)

0.9 kg

Voltage

90 to 260 VAC

Accuracy (ISE)

±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (mV)

±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Temperature)

±0.1°C

Alarm Output

High/low limit alarm

Calibration

pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points (pH)

1 to 6

Data Management Details

Transfer single, range or all data points to printer or computer

Description

Orion Dual Star pH/ISE dual channel benchtop meter with ROSS Ultra glass-body pH electrode, ATC probe and stand

Channels

2

Range (ISE)

0.0001 to 19,900 in ppm, M, mg/L, % or unit-less

Range (pH)

-2.000 to 19.999

Resolution (pH)

0.1, 0.01, 0.001

Display Type

Graphic LCD with Backlight

Inputs

Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Keypad

Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type

Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and

Methods

10 per channel with password protection

Power Supply

Universal AC adapter (included)

Range (ORP)

±1999.9 mV

Relative Humidity Range

5 to 85 %, non-condensing

Resolution (Temperature)

0.1°C, 0.1°F

Temperature (English) Operating

41°F to 113°F (ambient)

Temperature Probe Calibration

1 point temperature offset calibration

Warranty

3 Year Meter Warranty

Weight (English)

2 lb.

Electrical Requirements

90 to 260 VAC 50/60 Hz

Related Products

Img

Fischer Scientific

S72054

--

Img

Fischer Scientific

13-642-780

--

Img

Fischer Scientific

13-641-291

--

Img

Fischer Scientific

S72055

--

Img

Thermo Scientific™

13641291PM

--

Img

Thermo Scientific™

13-642-782PM

--

Img

Fischer Scientific

13-642-782

--

Img

Fischer Scientific

S72053

--

Description

  • Double your measurement capabilities with the Thermo Scientific™ Orion™ Dual Star™ pH and ISE Benchtop Meter
  • Record accurate and reliable pH, ion concentration, mV, ORP and temperature measurements on two available meter channels, ideal for high throughput pH and ion analysis in the lab
  • Perform up to 6 point pH and ISE calibrations, log up to 1000 data point sets with time/date stamp and easily transfer to a printer or computer
  • Use the two channels to measure a pH sample and ISE sample, two pH samples or two ISE samples simultaneously or view each channel separately
  • The Orion Dual Star pH/ISE dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display
  • Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the meter’s two BNC, reference pin-tip and ATC temperature inputs
  • Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable
  • The meter’s Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster
  • View large, individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time Easy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options EZ Startup menu facilitates quick and easy first-time meter setup Numeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry Selectable read modes include Auto-Read , On-Ready , At Timed Intervals , Continuous , Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods Perform up to a 6 point pH calibration with automatic recognition for USA/NIST and EURO/DIN buffers with option to manually input custom buffer values Perform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single/double known addition and single/double known subtraction Non-volatile meter memory holds up to 1000 data points with time and date stamp Easily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software Stir samples with ease using the meter-controlled Orion Star stirrer probe Meter-attachable electrode stand assists with moving and maintaining electrodes IP54-rated housing handles splashes and is wall-mountable to save space Warranty : 3-year meter replacement warranty Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement
  • Warranty and Services 3-year meter warranty

Compare Similar Items

Show Difference

Img

Fischer Scientific

13-642-781

--


AC Adapter:
Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)

Outputs:
USB, RS232

Accuracy (pH):
±0.002

Advanced ISE Functions:
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit

Backlight Option:
Yes, adjustable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
1000 with date and time stamp

Calibration Points (ISE):
2 to 6

Measurement Modes:
pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature

Range (mV):
±1999.9 mV

Resolution (ISE):
0.0001 minimum, 1 to 3 significant digits (user selectable)

Temperature (Metric) Range:
-5.0°C to +105.0°C

Includes:
Dual Star pH/ISE dual channel meter, 8102BNUWP ROSS Ultra glass-body pH electrode, 927007MD Orion stainless steel ATC probe, electrode stand, universal power adapter, literature, computer interface cable and meter test certificate

Isopotential Point:
7.000 pH (adjustable), 1.000 ISE (adjustable)

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter

Probe Type:
pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)

Range (Relative mV):
±1999.9 mV

Resolution (mV):
0.1 mV

Stability:
Smart Stability and Smart Averaging

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)

Weight (Metric):
0.9 kg

Voltage:
90 to 260 VAC

Accuracy (ISE):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Temperature):
±0.1°C

Alarm Output:
High/low limit alarm

Calibration:
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points (pH):
1 to 6

Data Management Details:
Transfer single, range or all data points to printer or computer

Description:
Orion Dual Star pH/ISE dual channel benchtop meter with ROSS Ultra glass-body pH electrode, ATC probe and stand

Channels:
2

Range (ISE):
0.0001 to 19,900 in ppm, M, mg/L, % or unit-less

Range (pH):
-2.000 to 19.999

Resolution (pH):
0.1, 0.01, 0.001

Display Type:
Graphic LCD with Backlight

Inputs:
Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Keypad:
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and

Methods:
10 per channel with password protection

Power Supply:
Universal AC adapter (included)

Range (ORP):
±1999.9 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Temperature):
0.1°C, 0.1°F

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Warranty:
3 Year Meter Warranty

Weight (English):
2 lb.

Electrical Requirements:
90 to 260 VAC 50/60 Hz

Img

Fischer Scientific

13-642-782

--


AC Adapter:
Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)

Outputs:
USB, RS232

Accuracy (pH):
±0.002

Advanced ISE Functions:
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit

Backlight Option:
Yes, adjustable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
1000 with date and time stamp

Calibration Points (ISE):
2 to 6

Measurement Modes:
pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature

Range (mV):
±1999.9 mV

Resolution (ISE):
0.0001 minimum, 1 to 3 significant digits (user selectable)

Temperature (Metric) Range:
-5.0°C to +105.0°C

Includes:
Dual Star Meter with Electrode Stand; Universal Power Adapter; 8102BNUWP ROSS Ultra Glass Refillable pH Electrode; 927007MD Stainless Steel ATC Probe; 810001 ROSS Storage Solution; 910104, 910107, 910110 pH 4.01, 7.00, 10.01 pH Buffers

Isopotential Point:
7.000 pH (adjustable), 1.000 ISE (adjustable)

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter

Probe Type:
pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)

Range (Relative mV):
±1999.9 mV

Resolution (mV):
0.1 mV

Stability:
Smart Stability and Smart Averaging

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)

Weight (Metric):
0.9 kg

Voltage:
90 to 260 VAC

Accuracy (ISE):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Temperature):
±0.1°C

Alarm Output:
High/low limit alarm

Calibration:
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points (pH):
1 to 6

Data Management Details:
Transfer single, range or all data points to printer or computer

Description:
Orion Dual Star pH/ISE dual channel benchtop meter kit with ROSS Ultra glass-body pH electrode, ATC probe, solutions and stand

Channels:
2

Range (ISE):
0.0001 to 19,900 in ppm, M, mg/L, % or unit-less

Range (pH):
-2.000 to 19.999

Resolution (pH):
0.1, 0.01, 0.001

Display Type:
Graphic LCD with Backlight

Inputs:
Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Keypad:
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and

Methods:
10 per channel with password protection

Power Supply:
Universal AC adapter (included)

Range (ORP):
±1999.9 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Temperature):
0.1°C, 0.1°F

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Warranty:
3 Year Meter Warranty

Weight (English):
2 lb.

Electrical Requirements:
90 to 260 VAC 50/60 Hz

Img

Thermo Scientific™

13-642-782PM

--


AC Adapter:
Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)

Outputs:
USB, RS232

Accuracy (pH):
±0.002

Advanced ISE Functions:
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit

Backlight Option:
Yes, adjustable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
1000 with date and time stamp

Calibration Points (ISE):
2 to 6

Measurement Modes:
pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature

Range (mV):
±1999.9 mV

Resolution (ISE):
0.0001 minimum, 1 to 3 significant digits (user selectable)

Temperature (Metric) Range:
-5.0°C to +105.0°C

Includes:
Dual Star Meter with Electrode Stand; Universal Power Adapter; 8102BNUWP ROSS Ultra Glass Refillable pH Electrode; 927007MD Stainless Steel ATC Probe; 810001 ROSS Storage Solution; 910104, 910107, 910110 pH 4.01, 7.00, 10.01 pH Buffers

Isopotential Point:
7 pH (adjustable), 1.000 ISE (adjustable)

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter

Probe Type:
pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)

Range (Relative mV):
±1999.9 mV

Resolution (mV):
0.1 mV

Stability:
Smart Stability and Smart Averaging

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)

Weight (Metric):
0.9 kg

Voltage:
90 to 260 VAC

Accuracy (ISE):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Temperature):
±0.1°C

Alarm Output:
High/low limit alarm

Calibration:
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points (pH):
1 to 6

Data Management Details:
Transfer single, range or all data points to printer or computer

Description:
Orion Dual Star pH/ISE dual channel benchtop meter kit with ROSS Ultra glass-body pH electrode, ATC probe, solutions and stand

Channels:
2

Range (ISE):
0.0001 to 19,900 in ppm, M, mg/L, % or unit-less

Range (pH):
-2.000 to 19.999

Resolution (pH):
0.1, 0.01, 0.001

Display Type:
Graphic LCD with Backlight

Inputs:
Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Keypad:
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and

Methods:
10 per channel with password protection

Power Supply:
Universal AC adapter (included)

Range (ORP):
±1999.9 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Temperature):
0.1°C, 0.1°F

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Warranty:
3 Year Meter Warranty

Weight (English):
2 lb.

Electrical Requirements:
90 to 260 VAC 50/60 Hz

Img

Fischer Scientific

13-642-785

--


AC Adapter:
Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)

Outputs:
USB, RS232

Accuracy (pH):
±0.002

Advanced ISE Functions:
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit

Backlight Option:
Yes, adjustable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
1000 with date and time stamp

Calibration Points (ISE):
2 to 6

Measurement Modes:
pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature

Range (mV):
±1999.9 mV

Resolution (ISE):
0.0001 minimum, 1 to 3 significant digits (user selectable)

Temperature (Metric) Range:
-5.0°C to +105.0°C

Includes:
Dual Star pH/ISE dual channel meter, 9512BNWP Orion ammonia ion selective electrode, 8172BNWP ROSS Sure-Flow glass-body pH electrode, 927007MD Orion stainless steel ATC probe, 096019 Orion Star series stirrer probe, 951207 Orion 100 ppm ammonia standard (475 mL), 951211 Orion ammonia ISA ionic strength adjuster (475 mL), 810199 ROSS pH buffer and solution kit, electrode stand, computer interface cable, universal power supply, literature and meter test certificate

Isopotential Point:
7.000 pH (adjustable), 1.000 ISE (adjustable)

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter

Probe Type:
pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8102BNUWP ROSS Ultra pH electrode, 927007MD Orion ATC probe)

Range (Relative mV):
±1999.9 mV

Resolution (mV):
0.1 mV

Stability:
Smart Stability and Smart Averaging

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)

Weight (Metric):
0.9 kg

Voltage:
__

Accuracy (ISE):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Temperature):
±0.1°C

Alarm Output:
High/low limit alarm

Calibration:
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points (pH):
1 to 6

Data Management Details:
Transfer single, range or all data points to printer or computer

Description:
Orion Dual Star pH/ISE dual channel benchtop meter ammonia & pH kit with Orion ammonia ion selective electrode, ROSS Sure-Flow glass-body pH electrode, ATC probe, solutions and stand

Channels:
2

Range (ISE):
0.0001 to 19,900 in ppm, M, mg/L, % or unit-less

Range (pH):
-2.000 to 19.999

Resolution (pH):
0.1, 0.01, 0.001

Display Type:
Graphic LCD with Backlight

Inputs:
Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Keypad:
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and

Methods:
10 per channel with password protection

Power Supply:
Universal AC adapter (included)

Range (ORP):
±1999.9 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Temperature):
0.1°C, 0.1°F

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Warranty:
3 Year Meter Warranty

Weight (English):
2 lb.

Electrical Requirements:
90 to 260 VAC 50/60 Hz