13641291PM

Thermo Scientific™ Orion™ Dual Star™ pH, ISE, mV, ORP and Temperature Dual Channel Benchtop Meter, PROMO

Manufacturer: Thermo Scientific™

The price for this product is unavailable. Please request a quote

AC Adapter

Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)

Accuracy (ISE)

±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (pH)

±0.002

Advanced ISE Functions

Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit

Backlight Option

Yes, adjustable

Calibration Points

1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance

CE, TUV 3-1, FCC Class A

Data Points

1000 with date and time stamp

Calibration Points (ISE)

2 to 6

Measurement Modes

pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature

Range (mV)

±1999.9 mV

Resolution (ISE)

0.0001 minimum, 1 to 3 significant digits (user selectable)

Temperature (Metric) Range

-5.0°C to +105.0°C

Includes

Dual Star pH/ISE dual channel meter, 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, universal power adapter, literature, computer interface cable and meter test certificate

Isopotential Point

7.000 pH (adjustable), 1.000 ISE (adjustable)

Languages

English, Spanish, French, Italian and German

Memory

Non-volatile memory preserves data log, calibration log and meter settings

Model

Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter

Probe Type

pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8157BNUMD ROSS Ultra Triode pH/ATC electrode)

Range (Relative mV)

±1999.9 mV

Resolution (mV)

0.1 mV

Stability

Smart Stability and Smart Averaging

Temperature (Metric) Operating

5°C to 45°C (ambient)

Temperature Selection

Manual or automatic with ATC temperature probe

Dimensions (L x W x H)

24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)

Weight (Metric)

0.9 kg

Voltage

90 to 260 VAC

Outputs

USB, RS232

Accuracy (mV)

±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Temperature)

±0.1°C

Alarm Output

High/low limit alarm

Calibration

pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points (pH)

1 to 6

Data Management Details

Transfer single, range or all data points to printer or computer

Description

Orion Dual Star pH/ISE dual channel benchtop meter with ROSS Ultra Triode epoxy-body pH/ATC electrode

Channels

2

Range (ISE)

0.0001 to 19,900 in ppm, M, mg/L, % or unit-less

Range (pH)

-2.000 to 19.999

Resolution (pH)

0.1, 0.01, 0.001

Display Type

Graphic LCD with Backlight

Inputs

Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Keypad

Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type

Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and

Methods

10 per channel with password protection

Power Supply

Universal AC adapter (included)

Range (ORP)

±1999.9 mV

Relative Humidity Range

5 to 85 %, non-condensing

Resolution (Temperature)

0.1°C, 0.1°F

Temperature (English) Operating

41°F to 113°F (ambient)

Temperature Probe Calibration

1 point temperature offset calibration

Warranty

3 Year Meter Warranty

Weight (English)

2 lb.

Electrical Requirements

90 to 260 VAC 50/60 Hz

Related Products

Img

Fischer Scientific

13-641-291

--

Img

Fischer Scientific

S72055

--

Img

Fischer Scientific

13-642-781

--

Img

Fischer Scientific

S72054

--

Img

Fischer Scientific

13-642-780

--

Img

Thermo Scientific™

13-642-782PM

--

Img

Fischer Scientific

13-642-782

--

Img

Fischer Scientific

S72053

--

Description

  • The dual channel benchtop meter accelerates sample measurement throughput by showing the results of two channels simultaneously on its large, backlit display
  • Measure pH, ion concentration (ISE), mV, relative mV or ORP with temperature on two channels using the two BNC, reference pin-tip and ATC temperature inputs
  • Collect critical measurements using an assortment of read modes and onscreen ready indicator that alerts when readings are stable
  • Its Smart Stability and Smart Averaging functions automatically compensate for measurement conditions, so the meter displays more accurate results faster
  • View large individual measurements on a full screen display or quickly toggle to a split screen display to view two measurements at the same time Easy-to-follow onscreen text prompts for calibration and setup menus available in a multi-language user interface with English, Spanish, French, German or Italian options EZ Startup menu facilitates quick and easy first time meter setup Numeric keypad and menu-specific function keys allow for quick and efficient meter setup and data entry Selectable read modes include Auto-Read, On-Ready, At Timed Intervals, Continuous, Value Change in Measurement and Timed for a variety of measurement collection methods for different analytical methods Perform up to a 6 point pH calibration with automatic recognition for USA/NIST and EURO/DIN buffers with option to manually input custom buffer values Perform up to a 6 point ion concentration (ISE) calibration with non-linear auto-blank and low-concentration stability options or use incremental methods for single/double known addition and single/double known subtraction Non-volatile meter memory holds up to 1000 data points with time and date stamp Easily transfer data via USB and RS232 to a printer or computer with free Orion Dual Star Com communication software Stir samples with ease using the meter-controlled Orion Star stirrer probe Meter-attachable electrode stand assists with moving and maintaining electrodes IP54-rated housing handles splashes and is wall-mountable to save space Three-year meter replacement warranty

Compare Similar Items

Show Difference

Img

Thermo Scientific™

13641291PM

--


AC Adapter:
Universal 50 to 60 Hz, 100 to 240 VAC power adapter (Cat. No. 1010003)

Accuracy (ISE):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (pH):
±0.002

Advanced ISE Functions:
Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stabilit

Backlight Option:
Yes, adjustable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
1000 with date and time stamp

Calibration Points (ISE):
2 to 6

Measurement Modes:
pH, mV, Relative mV, ORP, Ion Concentration (ISE) with Temperature

Range (mV):
±1999.9 mV

Resolution (ISE):
0.0001 minimum, 1 to 3 significant digits (user selectable)

Temperature (Metric) Range:
-5.0°C to +105.0°C

Includes:
Dual Star pH/ISE dual channel meter, 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, universal power adapter, literature, computer interface cable and meter test certificate

Isopotential Point:
7.000 pH (adjustable), 1.000 ISE (adjustable)

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Model:
Orion Dual Star pH/ISE/mV/RmV/ORP/Temperature Dual Channel Benchtop Meter

Probe Type:
pH electrode, ORP electrode, ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8157BNUMD ROSS Ultra Triode pH/ATC electrode)

Range (Relative mV):
±1999.9 mV

Resolution (mV):
0.1 mV

Stability:
Smart Stability and Smart Averaging

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24 x 17 x 9 cm (9.5 x 6.7 x 3.5 in.)

Weight (Metric):
0.9 kg

Voltage:
90 to 260 VAC

Outputs:
USB, RS232

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Temperature):
±0.1°C

Alarm Output:
High/low limit alarm

Calibration:
pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ

Calibration Points (pH):
1 to 6

Data Management Details:
Transfer single, range or all data points to printer or computer

Description:
Orion Dual Star pH/ISE dual channel benchtop meter with ROSS Ultra Triode epoxy-body pH/ATC electrode

Channels:
2

Range (ISE):
0.0001 to 19,900 in ppm, M, mg/L, % or unit-less

Range (pH):
-2.000 to 19.999

Resolution (pH):
0.1, 0.01, 0.001

Display Type:
Graphic LCD with Backlight

Inputs:
Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Keypad:
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read, On Ready, At Timed Intervals, Value Change In Measurement and

Methods:
10 per channel with password protection

Power Supply:
Universal AC adapter (included)

Range (ORP):
±1999.9 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (Temperature):
0.1°C, 0.1°F

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Warranty:
3 Year Meter Warranty

Weight (English):
2 lb.

Electrical Requirements:
90 to 260 VAC 50/60 Hz

Img

Sigma Aldrich

136441

98%...


AC Adapter:
__

Accuracy (ISE):
__

Accuracy (pH):
__

Advanced ISE Functions:
__

Backlight Option:
__

Calibration Points:
__

Certifications/Compliance:
__

Data Points:
__

Calibration Points (ISE):
__

Measurement Modes:
__

Range (mV):
__

Resolution (ISE):
__

Temperature (Metric) Range:
__

Includes:
__

Isopotential Point:
__

Memory:
__

Model:
__

Probe Type:
__

Range (Relative mV):
__

Resolution (mV):
__

Stability:
__

Temperature (Metric) Operating:
__

Temperature Selection:
__

Dimensions (L x W x H):
__

Weight (Metric):
__

Voltage:
__

Outputs:
__

Accuracy (mV):
__

Accuracy (Temperature):
__

Alarm Output:
__

Calibration:
__

Calibration Points (pH):
__

Data Management Details:
__

Description:
__

Channels:
__

Range (ISE):
__

Range (pH):
__

Resolution (pH):
__

Display Type:
__

Inputs:
__

Keypad:
__

Log Function Type:
__

Methods:
__

Power Supply:
__

Range (ORP):
__

Relative Humidity Range:
__

Resolution (Temperature):
__

Temperature (English) Operating:
__

Temperature Probe Calibration:
__

Warranty:
__

Weight (English):
__

Electrical Requirements:
__

Img

Sigma Aldrich

1365000

United States Pharmacopeia (USP) Re...


AC Adapter:
__

Accuracy (ISE):
__

Accuracy (pH):
__

Advanced ISE Functions:
__

Backlight Option:
__

Calibration Points:
__

Certifications/Compliance:
__

Data Points:
__

Calibration Points (ISE):
__

Measurement Modes:
__

Range (mV):
__

Resolution (ISE):
__

Temperature (Metric) Range:
__

Includes:
__

Isopotential Point:
__

Memory:
__

Model:
__

Probe Type:
__

Range (Relative mV):
__

Resolution (mV):
__

Stability:
__

Temperature (Metric) Operating:
__

Temperature Selection:
__

Dimensions (L x W x H):
__

Weight (Metric):
__

Voltage:
__

Outputs:
__

Accuracy (mV):
__

Accuracy (Temperature):
__

Alarm Output:
__

Calibration:
__

Calibration Points (pH):
__

Data Management Details:
__

Description:
__

Channels:
__

Range (ISE):
__

Range (pH):
__

Resolution (pH):
__

Display Type:
__

Inputs:
__

Keypad:
__

Log Function Type:
__

Methods:
__

Power Supply:
__

Range (ORP):
__

Relative Humidity Range:
__

Resolution (Temperature):
__

Temperature (English) Operating:
__

Temperature Probe Calibration:
__

Warranty:
__

Weight (English):
__

Electrical Requirements:
__

Img

Sigma Aldrich

1365043

United States Pharmacopeia (USP) Re...


AC Adapter:
__

Accuracy (ISE):
__

Accuracy (pH):
__

Advanced ISE Functions:
__

Backlight Option:
__

Calibration Points:
__

Certifications/Compliance:
__

Data Points:
__

Calibration Points (ISE):
__

Measurement Modes:
__

Range (mV):
__

Resolution (ISE):
__

Temperature (Metric) Range:
__

Includes:
__

Isopotential Point:
__

Memory:
__

Model:
__

Probe Type:
__

Range (Relative mV):
__

Resolution (mV):
__

Stability:
__

Temperature (Metric) Operating:
__

Temperature Selection:
__

Dimensions (L x W x H):
__

Weight (Metric):
__

Voltage:
__

Outputs:
__

Accuracy (mV):
__

Accuracy (Temperature):
__

Alarm Output:
__

Calibration:
__

Calibration Points (pH):
__

Data Management Details:
__

Description:
__

Channels:
__

Range (ISE):
__

Range (pH):
__

Resolution (pH):
__

Display Type:
__

Inputs:
__

Keypad:
__

Log Function Type:
__

Methods:
__

Power Supply:
__

Range (ORP):
__

Relative Humidity Range:
__

Resolution (Temperature):
__

Temperature (English) Operating:
__

Temperature Probe Calibration:
__

Warranty:
__

Weight (English):
__

Electrical Requirements:
__