4531964

Thermo Scientific™ TMTsixplex™ Isobaric Label Reagent Set

Amine-reactive Thermo Scientific TMT Isobaric Mass Tagging Kits and Reagents enable multiplex quantitation of proteins extracted from cells and tissues from up to 6 samples using tandem mass spectrometry.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

For Use With (Equipment)

Mass Spectrometer

Label or Dye

Tandem Mass Tag™ (TMT) Labels

Final Product Type

Protein

Workflow Step

Protein Labeling

Product Line

TMTsixplex™

Starting Material

Cell Lysate

Detection Method

Mass Spectrometry

Related Products

Img

Fischer Scientific

4589202

Use Iodoacetyl Tandem Mass Tag (iod...

Img

Fischer Scientific

7000094

The carbonyl-reactive Thermo Scient...

Img

Fischer Scientific

7228829

For enhanced enrichment, use Thermo...

Img

Fischer Scientific

9462003

The Thermo Scientific TMTpro 16plex...

Img

Fischer Scientific

PI90100

--

Img

Fischer Scientific

9462002

Thermo Scientific TMTpro Zero Label...

Img

Fischer Scientific

3660827

TMT10plex Isobaric Label Reagents a...

Img

Fischer Scientific

PI90104

--

Description

  • Tandem Mass Tag™ 6-plex (TMTsixplex™) Reagents are sets of isobaric compounds (i.e., same mass and structure, also called isotopomers) that are NHS-activated for covalent, irreversible labeling of primary amines (–NH2) groups
  • Each isobaric reagent contains a different number of heavy isotopes in the mass reporter region, which results in a unique reporter mass during tandem MS/MS for sample identification and relative quantitation
  • Amine-reactive Thermo Scientific TMT Isobaric Mass Tagging Kits and Reagents enable multiplex quantitation of proteins extracted from cells and tissues from up to 6 samples using tandem mass spectrometry
  • Features of TMTsixplex Label Reagents and Kits: • Powerful —multiplexed MS analysis increases sample throughput and enables relative quantitation of up to six different samples derived from cells, tissues or biological fluids • Robust —consistent chemistry allows efficient transition from method development to multiplex quantitation, enabling biomarker discovery research • Efficient —amine-reactive NHS-ester activated reagents ensures greater than 95% labeling of all peptides regardless of protein sequence or proteolytic enzyme specificity • Compatible —optimized for use with high resolution Thermo Scientific Orbitrap MS/MS platforms, with data analysis fully supported by Proteome Discoverer™ 2.3 and above Applications of TMTsixplex Label Reagents and Kits: • Protein identification and quantitation from multiple samples of cells, tissue or biological fluids • Protein expression profiling of normal vs
  • disease states or control vs
  • treated • Quantitative analysis of proteins for which no antibodies are available • Identification and quantitation of membrane and post-translationally modified proteins • Identification and quantitation of hundreds to thousands of proteins in a single experiment Since TMT reagents share an identical structure and mass (i.e., isotopomers), labeled peptides co-elute during LC separation and are co-isolated during MS/MS analysis, resulting in fewer missing peptide identifications among samples
  • During MS/MS analysis, each isobaric tag is also fragmented to produce a unique reporter ion mass that is used for sample identification and quantitation
  • Protein quantitation is accomplished by comparing the relative intensities of the six reporter ions
  • TMT Reagents are provided as standalone sets or in optimized kit formats containing all necessary reagents and controls for maximum flexibility, convenience, and reliability
  • Tandem Mass Tag Reagents combined with high resolution Thermo Scientific Orbitrap instruments and Proteome Discoverer software provide integrated total system solutions for quantitative protein expression analysis
  • For high resolution analysis of the TMT-labeled peptides, the recommended LC column for Nanospray Flex source is Acclaim PepMap 100 C18 LC Column (Cat
  • No
  • 164942 or 164939)
  • For EASY-Spray source, the recommended LC column is EASY-Spray C18 LC Column (Cat
  • No
  • ES902 or ES903).

Compare Similar Items

Show Difference

Img

Fischer Scientific

4531964

Amine-reactive Thermo Scientific TM...


For Use With (Equipment):
Mass Spectrometer

Label or Dye:
Tandem Mass Tag™ (TMT) Labels

Final Product Type:
Protein

Workflow Step:
Protein Labeling

Product Line:
TMTsixplex™

Starting Material:
Cell Lysate

Detection Method:
Mass Spectrometry

Img

Fischer Scientific

4531979

Thermo Scientific Pierce C18 Spin C...


For Use With (Equipment):
Microcentrifuge, Mass Spectrometer

Label or Dye:
__

Final Product Type:
Peptides

Workflow Step:
Sample Clean Up

Product Line:
Pierce™

Starting Material:
Peptides, Protease-digested Protein

Detection Method:
Mass Spectrometry

Img

Fischer Scientific

4531983

Pierce Protein Precipitation Plates...


For Use With (Equipment):
Mass Spectrometer, Centrifuge

Label or Dye:
__

Final Product Type:
Peptides

Workflow Step:
Sample Clean Up

Product Line:
Pierce™

Starting Material:
Protease-digested Protein

Detection Method:
Mass Spectrometry

Img

Fischer Scientific

4532004

Amplify signal in Western blot, ELI...


For Use With (Equipment):
__

Label or Dye:
__

Final Product Type:
__

Workflow Step:
__

Product Line:
Pierce™

Starting Material:
__

Detection Method:
__