7000094

Thermo Scientific™ aminoxyTMTsixplex™ Label Reagent Set

The carbonyl-reactive Thermo Scientific™ aminoxyTMT™ (Tandem Mass Tag™) Label Reagents enable multiplexed characterization and quantitation of carbonyl-containing biomolecules (carbohydrates, steroids, oxidized proteins) by mass spectrometry (MS).

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

For Use With (Equipment)

Mass Spectrometer

Starting Material

Cell Lysate

Detection Method

Mass Spectrometry

Product Line

aminoxyTMTsixplex™

Final Product Type

Protein

Workflow Step

Protein Labeling

Related Products

Img

Fischer Scientific

4531964

Amine-reactive Thermo Scientific TM...

Img

Fischer Scientific

4589202

Use Iodoacetyl Tandem Mass Tag (iod...

Img

Fischer Scientific

9462003

The Thermo Scientific TMTpro 16plex...

Img

Fischer Scientific

PI90100

--

Img

Fischer Scientific

7228829

For enhanced enrichment, use Thermo...

Img

Fischer Scientific

9462002

Thermo Scientific TMTpro Zero Label...

Img

Fischer Scientific

3660827

TMT10plex Isobaric Label Reagents a...

Img

Thermo Scientific™

PI90067

--

Description

  • The aminoxyTMTsixplex Label Reagents share an identical structure but contain different numbers of 13C and 15N isotopes in the mass reporter
  • The optimized labeling procedure can be completed in one hour
  • After tag labeling, samples are quenched and cleaned-up using HILIC solid-phase extraction before mass spectrometry analysis
  • The six compounds of the aminoxyTMTsixplex™ Reagent Set have the same mass (i.e., isobaric) and chemical structure (carbonyl-reactive aminoxy group, spacer arm, and mass reporter)
  • However, the specific distribution of 13C and 15N isotopes on either side of the HCD or ETD MS/MS fragmentation site in each reagent results in a unique reporter mass (126-131Da) in the low mass region
  • This set of reporter ions is used to measure the relative abundance of labeled molecules in a combined (multiplexed) MS sample representing six different treatment conditions
  • For glycobiology MS applications, the reagents enable quantitative profiling of glycan isoforms and discovery of glycan biomarkers; they provide improved ionization of labeled glycans for increased sensitivity and better retention of labeled glycans by reversed-phase liquid chromatography (RPLC)
  • The aminoxyTMT reagents may be used to quantify a broad range of biologically important molecules including carbohydrates, steroids, or oxidized proteins
  • Features: • Quantitative —enables relative quantitation of glycans or other carbonyl-containing biomolecules from multiple samples derived from cells, tissues or biological fluids • Stable —oxime bond and products formed by labeling reaction are stable and don't require an additional reduction step • Efficient —achieve labeling efficiency greater than 90% in one hour • Sensitive —20-fold increase in signal-to-noise compared to unlabeled native glycan MS analysis • Multiplex —able to identify and characterize up to six samples concurrently • Optimized —procedure and reagents optimized for excellent labeling efficiency and recovery of glycans Includes: • Label reagent sets contain sufficient aminoxyTMT tags for five sixplex experiments Requires: • PNGase F (or PNGase A) glycosidase and Waters Oasis™ HLB columns Applications: • Multiplex up to 6 different samples concurrently in a single experiment • Relative quantitation of glycans • Study of structural diversity of protein glycosylation • Study of glycosylation in cell signaling and regulation • Study of cancer progression, biomarker discovery and analysis of biotherapeutics Native glycans are difficult to study by mass spectrometry because of their poor ionization efficiency
  • Quantitation of glycans is particularly challenging due to the lack of standards for all naturally occurring glycans and difficulties reproducibly quantifying multiple samples
  • The aminoxy group has better reactivity with carbonyls and better stability of the labeled product compared to hydrazides
  • Labeling with the aminoxyTMT reagents improves ionization of glycans, thus improving sensitivity, and enables relative quantitation of glycans for up to six samples concurrently
  • These products are subject to a limited use label license.

Compare Similar Items

Show Difference

Img

Fischer Scientific

7000094

The carbonyl-reactive Thermo Scient...


For Use With (Equipment):
Mass Spectrometer

Starting Material:
Cell Lysate

Detection Method:
Mass Spectrometry

Product Line:
aminoxyTMTsixplex™

Final Product Type:
Protein

Workflow Step:
Protein Labeling

Img

Fischer Scientific

7000098

Purify recombinant c-Myc-tagged pro...


For Use With (Equipment):
__

Starting Material:
__

Detection Method:
__

Product Line:
Pierce™

Final Product Type:
__

Workflow Step:
__

Img

Fischer Scientific

7000099

Optimize applications where product...


For Use With (Equipment):
__

Starting Material:
__

Detection Method:
__

Product Line:
Pierce™

Final Product Type:
__

Workflow Step:
__

Img

Sigma Aldrich

700009P

--


For Use With (Equipment):
__

Starting Material:
__

Detection Method:
__

Product Line:
__

Final Product Type:
__

Workflow Step:
__