PI16175

Thermo Scientific™ Pierce™ Firefly Luciferase Flash Assay Kit

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 PI16175-Each-of-1 In Stock ₹ 71,613.72

PI16175 - Each of 1

₹ 71,613.72

In Stock

Quantity

1

Base Price: ₹ 71,613.72

GST (18%): ₹ 12,890.47

Total Price: ₹ 84,504.19

Type

Assay Kit

Quantity

1000 Reaction Kit

Assay

Reporter Enzyme, Luciferase Reporter Assay

Detection Method

Bioluminescence

Format

384-well plate, 96-well plate

Substrate Properties

Chemical Substrate

Substrate Type

Luciferase Substrate

Substrate

D-Luciferin

Target

Luciferase, Firefly Luciferase

Content And Storage

• Firefly Flash Assay Buffer, 5 mL, store at 4°C• D-Luciferin, 3 mg, store at 4°C• 2X Cell Lysis Buffer, 6 mL, store at room temperatureUpon receipt store kit at 4°C or store individual components as indicated above.

Compatible Cells

Mammalian Cells

For Use With (Equipment)

Luminometer (Microplate)

Label Type

Enzyme Labeled

Technique

Enhanced Chemiluminescence

Product Line

Pierce™

Related Products

Img

Fischer Scientific

PI16174

--

Img

Fischer Scientific

PI16177

--

Img

Fischer Scientific

PI16176

--

Img

Fischer Scientific

PI16181

--

Img

Fischer Scientific

PI16168

--

Img

Fischer Scientific

PI16169

--

Img

Fischer Scientific

PI16182

--

Img

Fischer Scientific

PI16170

--

Description

  • The Thermo Scientific™ Pierce Firefly Luciferase Flash Assay Kit provides reagents to measure Red firefly luciferase activity in whole cell producing a very strong flash signal which decays rapidly
  • Thermo Scientific Pierce Firefly Luciferase Flash Assay Kit contains reagents to measure the activity of firefly luciferase in mammalian whole cell lysates
  • Containing a convenient lysis buffer, assay buffer and firefly substrate, this kit provides a complete reagent system for the intracellular detection of promoter or pathway activity
  • Light output resulting from the luciferase reaction is captured using a luminometer and can be correlated with the amount of firefly luciferase protein produced and used to determine the activity of the promoter driving firefly expression
  • These reagents are optimized to work with Thermo Scientific Firefly Luc Plasmids; however, the Flash Assay Kit may be used to detect the activity of other firefly or ATP-dependent luciferases utilizing D-luciferin as a substrate
  • Highlights: Highly sensitive detection of firefly luciferase activity Use with Thermo Scientific Pierce Firefly Luciferase Signal Enhancer for best results (maximum signal) Working solution stable for up to 2 months at -20°C Assay reagents compatible with other firefly luciferases Amenable to automation Contains a universal cell lysis buffer and optimized flash assay reagent Safe non-radioactive assay Includes: Cell lysis buffer, reaction buffer and substrate Requires: Firefly luciferase and luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan Ascent and Varioskan Flash Microplate Readers; For best results (maximum signal), use with Thermo Scientific Pierce Firefly Luciferase Signal Enhancer Recommended for: Promoter studies for analyzing cis - regulatory elements and trans -acting factors; Drug screening; siRNA and miRNA screening; Multiplexed assays to study off-target effects; Secretory pathway / protein localization reporter assays; Signal transduction pathway analysis; RNA splicing studies

Compare Similar Items

Show Difference

Img

Fischer Scientific

PI16175

--


Type:
Assay Kit

Quantity:
1000 Reaction Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
D-Luciferin

Target:
Luciferase, Firefly Luciferase

Content And Storage:
• Firefly Flash Assay Buffer, 5 mL, store at 4°C• D-Luciferin, 3 mg, store at 4°C• 2X Cell Lysis Buffer, 6 mL, store at room temperatureUpon receipt store kit at 4°C or store individual components as indicated above.

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Product Line:
Pierce™

Img

Fischer Scientific

PI16176

--


Type:
Assay Kit

Quantity:
100 Reaction Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
D-Luciferin

Target:
Luciferase, Firefly Luciferase

Content And Storage:
• Firefly Glow Assay Buffer, 5 mL, store at -20°C• D-Luciferin, Lyophilized, 3 mg, store at 4°C• 2X Cell Lysis Buffer, 6 mL, store at room temperatureUpon receipt store kit at -20°C or store individual components as indicated above.

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Product Line:
__

Img

Fischer Scientific

PI16177

--


Type:
Assay Kit

Quantity:
1000 Reaction Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
D-Luciferin

Target:
Luciferase, Firefly Luciferase

Content And Storage:
• Firefly Glow Assay Buffer, 50 mL, store at -20°C• D-Luciferin, Lyophilized, 30 mg, store at 4°C• 2X Cell Lysis Buffer, 60 mL, store at room temperatureUpon receipt store kit at -20°C or store individual components as indicated above.

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Product Line:
Pierce™

Img

Thermo Scientific™

PI16180

--


Type:
Firefly Signal Enhancer

Quantity:
0.5 mL

Assay:
__

Detection Method:
Bioluminescence

Format:
__

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
__

Target:
__

Content And Storage:
Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, but do not store above -20°C.

Compatible Cells:
__

For Use With (Equipment):
__

Label Type:
__

Technique:
__

Product Line:
Pierce™