Concentration

dsDNA: Pedestal 27,500 ng/μL; BSA (IgG): Pedestal 820 (400) mg/mL

Detection Range

dsDNA: Pedestal 2 ng/μL, Cuvette 0.2 ng/μL; BSA (IgG): Pedestal 0.06 (0.03) mg/mL, Cuvette 0.006 (0.003) mg/mL

Display

Color Graphic

Languages

English, French, German, Spanish, Polish, Chinese, Japanese, Korean

Product Line

NanoDrop

Type

Spectrophotometer

Wavelength Range

190 to 850 nm

Includes

Qubit 4 Fluorometer (Q33226)

Measurement Time

8 sec.

Photometric Accuracy

3% at 0.97 A, 302 nm (Absorbance Expressed at Abs/mm at 25°C)

Power Consumption

5 to 18 W

Repeatability

0.002 A (1 mm Path) or 1% CV (SD of 10 Individual Measurements at 0.97 A)

Sample Volume (Metric)

1 μL

Wavelength Accuracy

±1 nm

Compatibility

DYMO LabelWriter 450 Printer, Bluetooth Keyboard, Mouse, Barcode Reader

Connections

USB-A, Ethernet, Bluetooth, Wi-Fi

Detector Type

CMOS Linear Image Sensor

Dimensions (L x W x H)

20 x 25.4 x 32.3 cm (8 x 10 x 12.7 in.)

Light Source

Pulsed Xenon

Spectral Bandwidth

≤1.8 nm

Voltage

12 VDC

For Use With (Application)

Nucleic Acid A260, A260/A280, A260/A230 and Labeled Nucleic Acids, Protein A280 and A205, Protein Pierce 660, Protein Bradford, Protein BCA, Protein Lowry, Labeled Proteins, OD600, Kinetics, UV-Vis, and Custom Methods

Keypad

Built-in Touchscreen, Multipoint Capacitive Touch

Pathlength

0.03 to 1 mm (Auto-ranging)

Photometric Range

Pedestal 0 to 550 A, Cuvette 0 to 1.5 A

Processor

Android™

Sample Temperature

37°C

System Requirements

Windows™ 8.1 and 10, 64 bit

Related Products

Img

Thermo Scientific™ Invitrogen™

13-400-525

--

Img

Thermo Scientific™

13-400-526

--

Img

Thermo Scientific

S28454

--

Img

Thermo Scientific

S72304

--

Img

Thermo Scientific™

14-380-442PM

--

Img

Thermo Scientific

S72307

--

Img

Thermo Scientific™

14-385-354

--

Img

Thermo Scientific

S72306

--

Description

  • NanoDrop One Microvolume UV-Vis Spectrophotometer Fast and easy sample evaluation of nucleic acids and proteins with pipette, measure, clean workflow and no sample carryover Modern stand-alone design with local control and high-resolution touchscreen interface, which saves bench space Accurate measurements up to 27,500 ng/μL (dsDNA) with extended auto-range path length technology No need for cuvettes or consumables needed so you can pipette directly onto pedestal sample retention system Pre-programmed applications designed specifically for life scientists Enhanced connectivity with data transfer via USB, Ethernet, Bluetooth™ and Wi-Fi options; PC software available for data management Qubit 4 Fluorometer Fast and highly accurate quantitation of DNA, RNA, and protein in less than three seconds per sample Measures intact RNA in less than 5 seconds per sample High levels of accuracy using only 1 to 20 μL of sample, even with very dilute samples On-board Reagent Calculator quickly generates Qubit working solution preparation instructions Stores results from up to 1000 samples Large 5.7-inch, state-of-the-art color touchscreen for easy workflow navigation Graphical display indicates when samples are in the extended range or out of range Small footprint saves space on your bench Exports data to a USB drive or directly to your computer via a USB cable Ability to personalize your Qubit fluorometer with the assays you run most, add new assays, or even create your own assays with the MyQubit software and web tool Language of your choice including English, French, Spanish, Italian, German, simplified Chinese, and Japanese Dynamic Range: 5 orders of magnitude Memory: 4 GB USB flash drive Emission filters: green (510 to 580 nm), red (665 to 720 nm) Excitation filters: blue (430 to 495 nm), red (600 to 645 nm) LED light sources: blue (max 470 nm), red (max 635 nm) Photodiode detectors: 300 to 1000 nm range

Compare Similar Items

Show Difference

Img

Thermo Scientific™ Invitrogen™

13-400-525S24

--


Certifications/Compliance:
CE and UL/CSA Approved

Concentration:
dsDNA: Pedestal 27,500 ng/μL; BSA (IgG): Pedestal 820 (400) mg/mL

Detection Range:
dsDNA: Pedestal 2 ng/μL, Cuvette 0.2 ng/μL; BSA (IgG): Pedestal 0.06 (0.03) mg/mL, Cuvette 0.006 (0.003) mg/mL

Display:
Color Graphic

Product Line:
NanoDrop

Type:
Spectrophotometer

Wavelength Range:
190 to 850 nm

Includes:
Qubit 4 Fluorometer (Q33226)

Measurement Time:
8 sec.

Photometric Accuracy:
3% at 0.97 A, 302 nm (Absorbance Expressed at Abs/mm at 25°C)

Power Consumption:
5 to 18 W

Repeatability:
0.002 A (1 mm Path) or 1% CV (SD of 10 Individual Measurements at 0.97 A)

Sample Volume (Metric):
1 μL

Wavelength Accuracy:
±1 nm

Compatibility:
DYMO LabelWriter 450 Printer, Bluetooth Keyboard, Mouse, Barcode Reader

Connections:
USB-A, Ethernet, Bluetooth, Wi-Fi

Detector Type:
CMOS Linear Image Sensor

Dimensions (L x W x H):
20 x 25.4 x 32.3 cm (8 x 10 x 12.7 in.)

Light Source:
Pulsed Xenon

Spectral Bandwidth:
≤1.8 nm

Voltage:
12 VDC

For Use With (Application):
Nucleic Acid A260, A260/A280, A260/A230 and Labeled Nucleic Acids, Protein A280 and A205, Protein Pierce 660, Protein Bradford, Protein BCA, Protein Lowry, Labeled Proteins, OD600, Kinetics, UV-Vis, and Custom Methods

Keypad:
Built-in Touchscreen, Multipoint Capacitive Touch

Pathlength:
0.03 to 1 mm (Auto-ranging)

Photometric Range:
Pedestal 0 to 550 A, Cuvette 0 to 1.5 A

Processor:
Android™

Sample Temperature:
37°C

System Requirements:
Windows™ 8.1 and 10, 64 bit

Img

Thermo Scientific™

13-400-526

--


Certifications/Compliance:
CE and UL/CSA Approved

Concentration:
dsDNA: Pedestal 27500 ng/μL; BSA (IgG): Pedestal 820 (400) mg/mL

Detection Range:
dsDNA: Pedestal 2 ng/μL, Cuvette 0.2 ng/μL; BSA (IgG): Pedestal 0.06 (0.03) mg/mL, Cuvette 0.006 (0.003) mg/mL

Display:
7 in. High Definition Color Display, 1280 x 800 pixels

Product Line:
NanoDrop OneC

Type:
Spectrophotometer

Wavelength Range:
190 to 850 nm

Includes:
Qubit™ 4 Fluorometer (Q33226)

Measurement Time:
8 seconds

Photometric Accuracy:
3% at 0.97 A, 302 nm (Absorbance expressed at Abs/mm at 25°C)

Power Consumption:
Operating: 12 to 18 W; Standby: 5 W

Repeatability:
0.002 A (1.0 mm path) or 1%CV (SD of 10 individual measurements at 0.97 A)

Sample Volume (Metric):
1 μL

Wavelength Accuracy:
±1 nm

Compatibility:
DYMO LabelWriter 450 printer, Bluetooth keyboard, mouse and barcode reader

Connections:
Three USB-A ports, Ethernet, Bluetooth™, and Wi-Fi

Detector Type:
2048-element CMOS Linear Image Sensor

Dimensions (L x W x H):
20 x 25.4 x 32.3 cm (8 x 10 x 12.7 in.)

Light Source:
Xenon Flash

Spectral Bandwidth:
≤1.8 nm (FWHM at Hg 254 nm)

Voltage:
12 VDC

For Use With (Application):
Nucleic Acid A260, A260/A280, A260/A230 and Labeled Nucleic Acids; Protein A280 and A205, Protein Pierce 660, Protein Bradford, Protein BCA, Protein Lowry, Labeled Proteins, OD600, Kinetics, UV-Vis, and Custom Methods

Keypad:
Built-in touchscreen, multipoint capacitive touch

Pathlength:
0.030 to 1.0 mm (auto-ranging)

Photometric Range:
10 mm equivalent: Pedestal 0 to 550 A, Cuvette 0 to 1.5 A

Processor:
Android™

Sample Temperature:
37°C

System Requirements:
Windows™ 8.1 and 10, 64 bit

Img

Thermo Scientific™

13-400-527LY

--


Certifications/Compliance:
__

Concentration:
__

Detection Range:
__

Display:
__

Product Line:
__

Type:
__

Wavelength Range:
190 to 850 nm

Includes:
__

Measurement Time:
<20 sec. (for 8 samples)

Photometric Accuracy:
__

Power Consumption:
3 W at Idle; 15 W at Working Conditions

Repeatability:
__

Sample Volume (Metric):
1 to 2 μL

Wavelength Accuracy:
± 1 nm

Compatibility:
__

Connections:
__

Detector Type:
Digital

Dimensions (L x W x H):
24 x 33 x 17 cm (9.4 x 13 x 6.7 in.)

Light Source:
Pulsed Xenon

Spectral Bandwidth:
__

Voltage:
100/240 V

For Use With (Application):
__

Keypad:
__

Pathlength:
1.0 mm, 0.2 mm, 0.1 mm (automatically adjusting)

Photometric Range:
__

Processor:
__

Sample Temperature:
__

System Requirements:
__

Img

Thermo Scientific™

13-400-533

--


Certifications/Compliance:
__

Concentration:
__

Detection Range:
__

Display:
__

Product Line:
__

Type:
__

Wavelength Range:
__

Includes:
Software is designed to integrate into the NanoDrop Eight PC software user interface. Software enable users to run the NanoDrop Eight instrument in a lab that needs to comply with US FDA 21 CFR Part 11. Includes: USB flash drive containing the SciVault software for the NanoDrop Eight Spectrophotometer

Measurement Time:
__

Photometric Accuracy:
__

Power Consumption:
__

Repeatability:
__

Sample Volume (Metric):
__

Wavelength Accuracy:
__

Compatibility:
__

Connections:
__

Detector Type:
__

Dimensions (L x W x H):
__

Light Source:
__

Spectral Bandwidth:
__

Voltage:
__

For Use With (Application):
__

Keypad:
__

Pathlength:
__

Photometric Range:
__

Processor:
__

Sample Temperature:
__

System Requirements:
__