14-380-442PM

Thermo Scientific™ GENESYS™ 30 Visible Spectrophotometer PROMO

Manufacturer: Thermo Scientific™

The price for this product is unavailable. Please request a quote

Baseline Flatness

<0.003 A, 325 to 1000 nm, smoothed

Connections

USB-A, USB-B

Detector Type

Silicon Photodiode

Dimensions (L x W x H)

35.5 x 38.5 x 19.5 cm

Spectral Bandwidth

5 nm

Drift

<0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup

Keypad

Tactile rubber 23 keys with numeric keypad

Noise

≤0.001A at 0A; ≤0.001A at 1A; ≤0.002A at 2A; RMS at 500 nm; 60 consecutive measurements

Photometric Accuracy

±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A)

Photometric Range

-3A to +3A

Printer Included

Thermal printer accessory with 80 mm width paper

Stray Light

<0.1%T at 340 nm and 400 nm; Measured using glass cutoff filters or NaNO2at 340 nm

Wavelength Accuracy

±2 nm

Wavelength Repeatability

< ±1 nm

Compartments

Accessible from top, front or side; Able to accommodate cells up to 100 mm pathlength; Available accessory for test-tubes up to 25 mm diameter and 150 mm height; Removable, washable sample compartment liner with magnetic placement and hold-down

Description

GENESYS 30 Visible Spectrophotometer

Display

32-bit Color

Languages

English, French, German, Spanish, Italian, Portuguese, Russian, Chinese, Japanese, Korean, Thai, Arabic

Wavelength Range

325 to 1100 nm

Electrical Requirements

External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz

Lamp Life

1000 hr.

Optical Design

Single Beam

Photometric Display

-3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C

Photometric Repeatability

± 0.002 A; Measured at 1.0 A at 546 nm

Scan Speed

Automatic – up to 1200 nm/min.

Warranty

2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase

Wavelength Data Interval

1 nm

Weight (Metric)

7.5 kg

Related Products

Img

Thermo Scientific

S28454

--

Img

Thermo Scientific

S72303

--

Img

Thermo Scientific

S72304

--

Img

Thermo Scientific

S72305

--

Img

Thermo Scientific

S72306

--

Img

Thermo Scientific™

14-385-354

--

Img

Thermo Scientific™

14-385-355

--

Img

Thermo Scientific

S72307

--

Description

  • Description The GENESYS 30 visible spectrophotometer brings you intuitive design, a high definition color screen, fast and accurate measurements, and convenient data reporting
  •  It is the ideal instrument for any user, whether a novice student or an experienced lab associate
  • Product Features: Entirely new industrial design for better usability High definition 5-inch color screen with rubberized push-button keypad for easy navigation Single cell measurement with removable, washable sample compartment liner Standard cell holder for 10mm cuvettes and optional holders for other cell types including test-tubes New onboard software UI; Thermo Scientific™ VISIONlite PC software is optional Data any way you want it USB data export in a text format that’s easy to read and process Excellent snap-on thermal printer available Three-year warranty and skilled technical support Meets curriculum topics for: Single wavelength Scanning Beer’s Law Colorimetry/colorimetric analysis Quantitative analysis Lab associate benefits: Higher data confidence with 6-point quant plus concentration mode Multiple local language choices

Compare Similar Items

Show Difference

Img

Thermo Scientific™

14-380-442PM

--


Baseline Flatness:
<0.003 A, 325 to 1000 nm, smoothed

Connections:
USB-A, USB-B

Detector Type:
Silicon Photodiode

Dimensions (L x W x H):
35.5 x 38.5 x 19.5 cm

Spectral Bandwidth:
5 nm

Drift:
<0.002 A/hr. (At 500 nm after 2 hr. warmup.) Typical <0.004 A/hr. after 1 hr. warmup

Keypad:
Tactile rubber 23 keys with numeric keypad

Noise:
≤0.001A at 0A; ≤0.001A at 1A; ≤0.002A at 2A; RMS at 500 nm; 60 consecutive measurements

Photometric Accuracy:
±0.002 A (0 to 0.3 A), 0.5% of ABS reading (0.301 A to 2.5 A)

Photometric Range:
-3A to +3A

Printer Included:
Thermal printer accessory with 80 mm width paper

Stray Light:
<0.1%T at 340 nm and 400 nm; Measured using glass cutoff filters or NaNO2at 340 nm

Wavelength Accuracy:
±2 nm

Wavelength Repeatability:
< ±1 nm

Compartments:
Accessible from top, front or side; Able to accommodate cells up to 100 mm pathlength; Available accessory for test-tubes up to 25 mm diameter and 150 mm height; Removable, washable sample compartment liner with magnetic placement and hold-down

Description:
GENESYS 30 Visible Spectrophotometer

Display:
32-bit Color

Wavelength Range:
325 to 1100 nm

Electrical Requirements:
External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100/250 V, 50/60 Hz

Lamp Life:
1000 hr.

Optical Design:
Single Beam

Photometric Display:
-3A to +3A, 0 to 200 000 %T, 0 to 9 999 999 C

Photometric Repeatability:
± 0.002 A; Measured at 1.0 A at 546 nm

Scan Speed:
Automatic – up to 1200 nm/min.

Warranty:
2 years standard with 1 year extension upon registration of the instrument with Thermo Fisher Scientific within 6 months of purchase

Wavelength Data Interval:
1 nm

Weight (Metric):
7.5 kg

Img

Thermo Scientific™

14-380-459

--


Baseline Flatness:
__

Connections:
__

Detector Type:
__

Dimensions (L x W x H):
__

Spectral Bandwidth:
__

Drift:
__

Keypad:
__

Noise:
__

Photometric Accuracy:
__

Photometric Range:
__

Printer Included:
__

Stray Light:
__

Wavelength Accuracy:
__

Wavelength Repeatability:
__

Compartments:
__

Description:
Smart Thermostatted Rotary 7-Cell Changer

Display:
__

Wavelength Range:
__

Electrical Requirements:
__

Lamp Life:
__

Optical Design:
__

Photometric Display:
__

Photometric Repeatability:
__

Scan Speed:
__

Warranty:
__

Wavelength Data Interval:
__

Weight (Metric):
__

Img

Thermo Scientific™

14-380-469

--


Baseline Flatness:
__

Connections:
__

Detector Type:
__

Dimensions (L x W x H):
__

Spectral Bandwidth:
__

Drift:
__

Keypad:
__

Noise:
__

Photometric Accuracy:
__

Photometric Range:
__

Printer Included:
__

Stray Light:
__

Wavelength Accuracy:
__

Wavelength Repeatability:
__

Compartments:
__

Description:
__

Display:
__

Wavelength Range:
__

Electrical Requirements:
__

Lamp Life:
__

Optical Design:
__

Photometric Display:
__

Photometric Repeatability:
__

Scan Speed:
__

Warranty:
__

Wavelength Data Interval:
__

Weight (Metric):
__

Img

Fischer Scientific

14-380-800

--


Baseline Flatness:
__

Connections:
__

Detector Type:
__

Dimensions (L x W x H):
__

Spectral Bandwidth:
__

Drift:
__

Keypad:
__

Noise:
__

Photometric Accuracy:
__

Photometric Range:
__

Printer Included:
__

Stray Light:
__

Wavelength Accuracy:
__

Wavelength Repeatability:
__

Compartments:
__

Description:
Maintains 0°C temperature for 60 min.

Display:
__

Wavelength Range:
__

Electrical Requirements:
__

Lamp Life:
__

Optical Design:
__

Photometric Display:
__

Photometric Repeatability:
__

Scan Speed:
__

Warranty:
__

Wavelength Data Interval:
__

Weight (Metric):
__