PI88527

Thermo Scientific™ Pierce™ Protein Concentrators PES, 10K MWCO, 0.5–100 mL

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 PI88527-Each-of-1 In Stock ₹ 18,138.72

PI88527 - Each of 1

₹ 18,138.72

In Stock

Quantity

1

Base Price: ₹ 18,138.72

GST (18%): ₹ 3,264.97

Total Price: ₹ 21,403.69

Content And Storage

Store at room temperature.

Disposable

Single-use

MWCO

10 kDa

Product Line

Pierce™

Quantity

10 Concentrators

Type

Filter

Description

Pierce™ Protein Concentrator PES, 10K MWCO, 5-20 mL

Material (Membrane)

PES

Sample Volume

5 to 20 mL

Purification Target

Protein

Shipping Condition

Room Temperature

Related Products

Img

Fischer Scientific

PI88528

--

Img

Fischer Scientific

PI88516

--

Img

Fischer Scientific

PI88535

--

Img

Fischer Scientific

PI88517

--

Img

Fischer Scientific

PI88513

--

Img

Fischer Scientific

PI88516S

--

Img

Thermo Scientific™

FER88537X4

--

Img

Thermo Scientific™

FER88523X4

--

Description

  • Quickly concentrate proteins and biological samples with Thermo Scientific Pierce Protein Concentrators PES (polyethersulfone), which are disposable ultrafiltration centrifugation devices that enable fast sample recovery and a short processing time
  • These concentrator columns can be used with standard microcentrifuge equipment, and samples can be collected without the need for invert spinning
  • Samples can be concentrated with or without desalting
  • These concentrators have a molecular weight cutoff (MWCO) of 10K and can be used for processing volumes from 0.5 to 100 mL
  • For protein and other biological samples, such as nucleic acids, with a 10K MWCO, Pierce Protein Concentrators PES offer rapid protein concentration, excellent sample recovery, and instrument compatibility
  • These centrifugal devices feature a high-flux polyethersulfone (PES) membrane for concentration, desalting, and buffer exchange of biological samples
  • These concentrators have a MWCO of 10K and can be used for processing sample volumes from 0.5 to 100 mL
  • Features of 10K MWCO Protein Concentrators PES include: • Rapid protein concentration —sample concentration of 10- to 30-fold can be achieved in 10 or fewer minutes using the 0.5-mL concentrator and 15 or fewer minutes using the other quantity concentrators • Excellent protein recovery —typical protein recovery is >90% (when the sample mass is at least two-fold greater than the posted MWCO) • Instrument-compatibility —a standard microcentrifuge with swinging (except 88513) or fixed-angle rotors can be used; sample can be collected and recovered without invert spinning • Versatile —easily perform sample concentration, diafiltration, or buffer-exchange of biological samples For easy identification, the MWCO value is etched on the side of each device
  • To assist with sample addition and recovery, a clear window with graduations is located on the side of each device, enabling visual determination of the retentate volume
  • The vertical design of the membrane allows high-flux rates, low non-specific binding, and negligible protein aggregation on the membrane, giving reliable and consistent results for processing sample volumes between 0.5 and 100 mL
  • Typical protein recovery is 90% when the mass of the proteins in the sample is at least two-fold greater than the MWCO of the device used
  • For example, when concentrating IgG (MW ∼150 KDa) samples, use the 3K, 10K, 30K, or 50K MWCO concentrators
  • Final sample concentrations of 10- to 30-fold can be achieved within 10 minutes when using the 0.5 mL concentrators and within 15 minutes when using the other concentrator sizes
  • Protein Concentrators PES applications • Protein concentration of tissue culture media, antiserum, or monoclonal antibody preparations • Concentration of protein peaks following gel-permeation chromatography • Removal of unincorporated label following protein modification reactions • Concentration and desalt/buffer-exchange after elution of protein from ion-exchange • Separation of different sized molecules Pierce Protein Concentrators PES centrifugal devices contain a membrane rated for retaining molecules with a molecular weight at least two-fold greater than the MWCO rating of the PES membrane within the device
  • Reduced recovery may occur when using a concentrator with molecules smaller than the recommended mass
  • Protein recovery will vary depending on the specific protein in the sample and its starting concentration
  • The dead-stop volume for the 0.5 mL, 2–6 mL, 5–20 mL, and 20–100 mL concentrators is approximately 15 μL, 30 μL, 50 μL, and 350 μL, respectively
  • To achieve >90% recovery of protein with the 0.5 mL concentrators, the minimum protein sample concentration should be 0.05 mg/mL
  • For all other concentrators, the minimum protein sample concentration should be 0.1 mg/mL
  • Optimal centrifuges and speeds The 0.5-mL concentrators can be used effectively at a maximum centrifugal force of 15,000 × g, using a fixed angle centrifuge only
  • For the 2-6 mL concentrators, swinging-bucket or fixed-angle centrifuge models can be used
  • Swinging bucket centrifuges capable of generating 2,000–4,000 × g and a maximum centrifugal force of 4,000 × g are recommended
  • With fixed-angle centrifuges, models capable of generating 5,000–10,000 × g and a maximum centrifugal force of 8,000 × g are recommended
  • For the 5-20 mL volume concentrators, swinging-bucket or fixed-angle centrifuge models can be used
  • Swinging-bucket centrifuges capable of generating 2,000–5,000 × g and a maximum centrifugal force of 4,000 × g are recommended
  • With fixed-angle centrifuges, models capable of generating 5,000–8,000 × g and a maximum centrifugal force of 6,000 × g are recommended
  • For the 20-100 mL concentrators, only swinging-bucket centrifuges capable of generating 1,000–2,000 × g are recommended
  • Use a maximum centrifugal force of 2,000 × g for the 20–100 mL concentrators
  • The concentrators are not recommended for use in fixed-angle rotors
  • Centrifugal force, temperature and sample volume, concentration and viscosity will affect filtration rate and require optimization of time for each application.

Compare Similar Items

Show Difference

Img

Fischer Scientific

PI88527

--


Content And Storage:
Store at room temperature.

Disposable:
Single-use

MWCO:
10 kDa

Product Line:
Pierce™

Quantity:
10 Concentrators

Type:
Filter

Description:
Pierce™ Protein Concentrator PES, 10K MWCO, 5-20 mL

Material (Membrane):
PES

Sample Volume:
5 to 20 mL

Purification Target:
Protein

Shipping Condition:
Room Temperature

Img

Fischer Scientific

PI88528

--


Content And Storage:
Store at room temperature.

Disposable:
Single-use

MWCO:
10 kDa

Product Line:
Pierce™

Quantity:
24 Concentrators

Type:
Filter

Description:
Pierce™ Protein Concentrator PES, 10K MWCO, 5-20 mL

Material (Membrane):
PES

Sample Volume:
5 to 20 mL

Purification Target:
Protein

Shipping Condition:
Room Temperature

Img

Fischer Scientific

PI88532

--


Content And Storage:
Store at Room Temperature.

Disposable:
Single-use

MWCO:
100 kDa

Product Line:
Pierce™

Quantity:
10 Concentrators

Type:
Filter

Description:
Pierce™ Protein Concentrator PES, 100K MWCO, 5-20 mL

Material (Membrane):
PES

Sample Volume:
5 to 20 mL

Purification Target:
Protein

Shipping Condition:
Room Temperature

Img

Fischer Scientific

PI88532S

--


Content And Storage:
Store at Room Temperature.

Disposable:
Single-use

MWCO:
100 kDa

Product Line:
Pierce

Quantity:
2 x 10 Concentrators

Type:
Spin Column

Description:
Pierce™ Protein Concentrator PES, 100K MWCO, 5-20 mL

Material (Membrane):
PES

Sample Volume:
5 to 20 mL

Purification Target:
Protein

Shipping Condition:
Room Temperature