4529592

Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter

Get premium performance and flexibility with our benchtop meter with pH and conductivity modules for simultaneous pH, conductivity, and temperature.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Outputs

USB (2), RS232

Accuracy (Conductivity)

0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS

Accuracy (pH)

±0.002

Accuracy (Salinity)

0.5% of reading ±1 digit

Alarm Output

Set point alarm, high/low limit alarm, calibration due alarm

Calibration

pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op

Calibration Points (Conductivity)

Up to 6

Cell Constant

0.001 to 199.9cm-1

Data Management Details

Transfer single, range or all data points to printer or computer

Channels

4 - customizable with modules

IP Rating

IP 54

Range (Conductivity)

0.001 μS/cm to 3000 mS/cm

Range (pH)

-2.000 to 20.000

Range (Salinity)

0.06 to 80.00 psu, 0.05 to 42.00 ppt

Resolution (pH)

0.1/0.01/0.001

Inputs

BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe)

Keypad

Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type

Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with

Methods

10 per channel

Power Supply

Universal AC adapter (included)

Range (Relative mV)

±2000.0 mV

Resolution (Conductivity)

0.001 μS minimum, auto ranging up to 4 significant digits

Resolution (Resistivity)

1 ohm or 0.1 meg-ohm, auto ranging

Resolution (TDS)

0.001 ppm minimum, auto ranging up to 4 significant digits

Stability

Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature Accuracy

±0.1°C

Temperature (English) Operating

41°F to 113°F (ambient)

Temperature (Metric) Reference

5, 10, 15, 20, 25°C

Temperature Range (English)

22.0°F to 221.0° F

Temperature Selection

Manual or automatic with ATC temperature probe

Dimensions (L x W x H)

28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H

Weight (Metric)

1.2 kg, modules add 0.2 kg each

AC Adapter

Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)

Accuracy (mV)

±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Resistivity)

0.5% of reading ±1 digit

Accuracy (TDS)

0.5% of reading ±1 digit

Backlight Option

Yes

Calibration Points

1 point relative mV (RmV) mode, 1 point ORP mode

Calibration Points (pH)

1 to 6

Certifications/Compliance

CE, TUV 3-1, FCC Class A

Data Points

2000 with date and time stamp

Display Type

Color graphic LCD with user-customizable options

Measurement Modes

pH, mV, Relative mV, TDS, ORP with Temperature, Salinity, Conductivity, Resistivity with Temperature

Range (mV)

±2000.0 mV

Range (Resistivity)

2 ohm to 100.0 meg-ohm

Range (TDS)

0.001 ppm to 200.0 ppt

Temperature Range (Metric)

-5.0°C to +105.0°C

Isopotential Point

7.000pH (adjustable)

Languages

English, Spanish, French, Italian, German, Chinese, Portuguese and Korean

Memory

Non-volatile memory preserves data log, calibration log and meter settings

Power Rating

DC input: 9VDC, 1A

Range (ORP)

±2000.0 mV

Relative Humidity Range

5 to 85 %, non-condensing

Resolution (mV)

0.1mV

Resolution (Salinity)

0.01 psu or 0.01 ppt minimum, auto ranging

Salinity Measurement Modes

Practical salinity (psu) or natural sea water (ppt)

TDS Factor Range

Linear (0.02 to 9.99)

Temperature Compensation

Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off

Temperature (Metric) Operating

5°C to 45°C (ambient)

Temperature Probe Calibration

1 point temperature offset calibration

Temperature Resolution

0.1°C, 0.1°F

Warranty

3 year meter and module warranty

Weight (English)

2.5 lb., modules add 0.5 lb. each

Related Products

Img

Fischer Scientific

13-645-583

--

Img

Fischer Scientific

4529602

Reliably measure pH, conductivity a...

Img

Fischer Scientific

4529612

Accurately measure pH, conductivity...

Img

Fischer Scientific

13-645-584

--

Img

Fischer Scientific

13-645-563

--

Img

Fischer Scientific

13-645-545

--

Img

Thermo Scientific™

13-645-547PM

--

Img

Thermo Scientific™

13-645-584PM

--

Description

  • Get high accuracy, premium performance and ultimate flexibility with the Thermo Scientific™ Orion™ Versa Star Pro™ pH/Conductivity Multiparameter Benchtop Meter
  • Meet your most challenging applications for pH, mV, ORP, conductivity, total dissolved solids (TDS), salinity, resistivity and temperature
  • Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules
  • View pH and conductivity simultaneously or view each channel separately
  • Log up to 2000 data point sets with time/date stamp and easily transfer logs to a printer or computer
  • Thermo Scientific Orion Versa Star Pro Benchtop Meters are designed to meet your most challenging application with ease
  • Delivering rich functionality and features, you can optimally configure your meter system to meet changing requirements
  • The Orion Versa Star Pro Benchtop Meters offer interchangeable measurement modules that allow multiple users to customize four separate channels to meet their specific requirements
  • Easily view your measurements on a stunning color display with adjustable text sizes
  • Take the guesswork out of meter calibration and setup with onscreen instructions available in a variety of local languages
  • Enjoy quick and simple data entry using the numeric keypad
  • Onscreen measurement stability indicator lets you know exactly when your measurements are ready Selectable read modes include Auto-Read to hold a stable reading, Continuous to show changing readings, Timed to log data at specific intervals and Single-Shot to hold a reading after a specific wait time is reached Audible alarms automatically notify you when a set offset value, high/low limit value, and calibration time interval are reached Easily access, update and switch your preferred measurement settings, using 10 password-protected methods per channel Uniformly mix solutions using up to two meter-controlled stirrer probes that are easy to position and can be quickly rinsed between samples Data log collects and date/time stamps up to 2000 measurement sets with optional electrode ID, sample ID and account ID Calibration log stores 30 most recent calibrations per parameter with viewable graph for multipoint pH and ISE calibrations Ensure measurement integrity by viewing the active calibration log while taking readings Non-volatile meter memory preserves data and settings, even in the event of power loss Meter facilitates data transfers to a computer via USB or RS232 connections IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited Meters include CE, TUV 3-in-1 and FCC Class A certifications 3-year replacement warranty Includes Orion Versa Star pH Measurement Module: Measure pH, mV, relative mV or ORP with temperature Perform up to a 6 point pH calibration using automatic buffer recognition of NIST, DIN or user-defined buffer groups with choice to manually enter custom buffer values Calibration editing option allows individual points to be fixed without a full recalibration Includes Orion Versa Star Conductivity Measurement Module: Measure conductivity, TDS, salinity or resistivity with temperature Perform up to a 6 point conductivity calibration with calibration editing option that allows individual points to be fixed without a full recalibration Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate Use linear, non-linear, EP (USP) or off conductivity temperature compensation with 5°C, 10°C, 15°C, 20°C or 25°C reference temperatures System Access Feature Orion Versa Star Pro meters offer a system access feature that is designed to help ensure data integrity by preventing undesired access to various meter functions including date/time setting, data log and calibration log
  • The System Access feature can be easily turned on or off as the needs of your lab change for ultimate flexibility in operation and ease-of-use
  • When enabled, the System Access feature allows assignment of a system administrator and up to 10 user accounts with customizable access to instrument settings, measurement settings, calibrations and logs
  • Use the password protection to secure selected meter functions, while leaving other functions accessible for all users
  • The System Access feature allows you to customize meter access to meet your specific security and data reporting needs
  • Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Compare Similar Items

Show Difference

Img

Fischer Scientific

4529592

Get premium performance and flexibi...


Outputs:
USB (2), RS232

Accuracy (Conductivity):
0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS

Accuracy (pH):
±0.002

Accuracy (Salinity):
0.5% of reading ±1 digit

Alarm Output:
Set point alarm, high/low limit alarm, calibration due alarm

Calibration:
pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op

Calibration Points (Conductivity):
Up to 6

Cell Constant:
0.001 to 199.9cm-1

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
4 - customizable with modules

IP Rating:
IP 54

Range (Conductivity):
0.001 μS/cm to 3000 mS/cm

Range (pH):
-2.000 to 20.000

Range (Salinity):
0.06 to 80.00 psu, 0.05 to 42.00 ppt

Resolution (pH):
0.1/0.01/0.001

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 8 pin MiniDIN (conductivity sensor with built-in temperature), two stirrer inputs (stirrer probe)

Keypad:
Numeric with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with

Methods:
10 per channel

Power Supply:
Universal AC adapter (included)

Range (Relative mV):
±2000.0 mV

Resolution (Conductivity):
0.001 μS minimum, auto ranging up to 4 significant digits

Resolution (Resistivity):
1 ohm or 0.1 meg-ohm, auto ranging

Resolution (TDS):
0.001 ppm minimum, auto ranging up to 4 significant digits

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature Accuracy:
±0.1°C

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature (Metric) Reference:
5, 10, 15, 20, 25°C

Temperature Range (English):
22.0°F to 221.0° F

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
28cm x 24cm x 10cm (11 in. x 9.5 in. x 3.9 in.), modules add ≤ 2cm (0.8 in.) L & H

Weight (Metric):
1.2 kg, modules add 0.2 kg each

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR)

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Resistivity):
0.5% of reading ±1 digit

Accuracy (TDS):
0.5% of reading ±1 digit

Backlight Option:
Yes

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Calibration Points (pH):
1 to 6

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
2000 with date and time stamp

Display Type:
Color graphic LCD with user-customizable options

Measurement Modes:
pH, mV, Relative mV, TDS, ORP with Temperature, Salinity, Conductivity, Resistivity with Temperature

Range (mV):
±2000.0 mV

Range (Resistivity):
2 ohm to 100.0 meg-ohm

Range (TDS):
0.001 ppm to 200.0 ppt

Temperature Range (Metric):
-5.0°C to +105.0°C

Isopotential Point:
7.000pH (adjustable)

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Power Rating:
DC input: 9VDC, 1A

Range (ORP):
±2000.0 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (mV):
0.1mV

Resolution (Salinity):
0.01 psu or 0.01 ppt minimum, auto ranging

Salinity Measurement Modes:
Practical salinity (psu) or natural sea water (ppt)

TDS Factor Range:
Linear (0.02 to 9.99)

Temperature Compensation:
Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Temperature Resolution:
0.1°C, 0.1°F

Warranty:
3 year meter and module warranty

Weight (English):
2.5 lb., modules add 0.5 lb. each

Img

Fischer Scientific

4529599

Reliably measure pH, dissolved oxyg...


Outputs:
USB, RS232

Accuracy (Conductivity):
__

Accuracy (pH):
±0.002

Accuracy (Salinity):
__

Alarm Output:
High/low limit alarm, calibration due alarm

Calibration:
pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature

Calibration Points (Conductivity):
__

Cell Constant:
__

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
2

IP Rating:
IP 54

Range (Conductivity):
__

Range (pH):
-2.000 to 20.000

Range (Salinity):
__

Resolution (pH):
0.1/0.01/0.001

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)

Keypad:
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Methods:
10 per channel with password protection

Power Supply:
Universal AC adapter (included) or 4 AA batteries (sold separately)

Range (Relative mV):
±2000.0 mV

Resolution (Conductivity):
__

Resolution (Resistivity):
__

Resolution (TDS):
__

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature Accuracy:
±0.1°C

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature (Metric) Reference:
__

Temperature Range (English):
22.0°F to 221.0° F

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.)

Weight (Metric):
0.9 kg

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Resistivity):
__

Accuracy (TDS):
__

Backlight Option:
Yes, selectable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Calibration Points (pH):
1 to 5

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
2000 with date and time stamp

Display Type:
LCD Graphic, Backlit

Measurement Modes:
pH, mV, Relative mV, ORP with Temperature, Dissolved Oxygen (% Saturation), Dissolved Oxygen (mg/L with Temperature)

Range (mV):
±2000.0 mV

Range (Resistivity):
__

Range (TDS):
__

Temperature Range (Metric):
-5.0°C to +105.0°C

Isopotential Point:
7.000pH

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Power Rating:
__

Range (ORP):
±2000.0 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (mV):
0.1mV

Resolution (Salinity):
__

Salinity Measurement Modes:
__

TDS Factor Range:
__

Temperature Compensation:
__

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Temperature Resolution:
0.1°C, 0.1°F

Warranty:
3 Year Meter

Weight (English):
2 lb.

Img

Fischer Scientific

4529602

Reliably measure pH, conductivity a...


Outputs:
USB, RS232

Accuracy (Conductivity):
0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS

Accuracy (pH):
±0.002

Accuracy (Salinity):
0.5% of reading ±1 digit

Alarm Output:
High/low limit alarm, calibration due alarm

Calibration:
pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op

Calibration Points (Conductivity):
Up to 5

Cell Constant:
0.001 to 199.9cm-1

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
2

IP Rating:
IP 54

Range (Conductivity):
0.001 μS/cm to 3000 mS/cm

Range (pH):
-2.000 to 20.000

Range (Salinity):
0.06 to 80.00 psu, 0.05 to 42.00 ppt

Resolution (pH):
0.1/0.01/0.001

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), stirrer input (stirrer probe)

Keypad:
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Methods:
10 per channel with password protection

Power Supply:
Universal AC adapter (included) or 4 AA batteries (sold separately)

Range (Relative mV):
±2000.0 mV

Resolution (Conductivity):
0.001 μS minimum, auto ranging up to 4 significant digits

Resolution (Resistivity):
1 ohm or 0.1 meg-ohm, auto ranging

Resolution (TDS):
0.001 ppm minimum, auto ranging up to 4 significant digits

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature Accuracy:
±0.1°C

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature (Metric) Reference:
5, 10, 15, 20, 25°C

Temperature Range (English):
22.0°F to 221.0° F

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.)

Weight (Metric):
0.9 kg

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Resistivity):
0.5% of reading ±1 digit

Accuracy (TDS):
0.5% of reading ±1 digit

Backlight Option:
Yes, selectable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Calibration Points (pH):
1 to 5

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
2000 with date and time stamp

Display Type:
LCD Graphic, Backlit

Measurement Modes:
__

Range (mV):
±2000.0 mV

Range (Resistivity):
2 ohm to 100.0 meg-ohm

Range (TDS):
0.001 ppm to 200.0 ppt

Temperature Range (Metric):
-5.0°C to +105.0°C

Isopotential Point:
7.000pH

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Power Rating:
__

Range (ORP):
±2000.0 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (mV):
0.1mV

Resolution (Salinity):
0.01 psu or 0.01 ppt minimum, auto ranging

Salinity Measurement Modes:
Practical salinity (psu) or natural sea water (ppt)

TDS Factor Range:
Linear (0.02 to 9.99)

Temperature Compensation:
Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Temperature Resolution:
0.1°C, 0.1°F

Warranty:
3 Year Meter

Weight (English):
2 lb.

Img

Fischer Scientific

4529609

Accurately measure pH, dissolved ox...


Outputs:
USB, RS232

Accuracy (Conductivity):
__

Accuracy (pH):
±0.002

Accuracy (Salinity):
__

Alarm Output:
High/low limit alarm, calibration due alarm

Calibration:
pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature

Calibration Points (Conductivity):
__

Cell Constant:
__

Data Management Details:
Transfer single, range or all data points to printer or computer

Channels:
2

IP Rating:
IP 67

Range (Conductivity):
__

Range (pH):
-2.000 to 20.000

Range (Salinity):
__

Resolution (pH):
0.1/0.01/0.001

Inputs:
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature)

Keypad:
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Log Function Type:
Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Methods:
10 per channel with password protection

Power Supply:
4 AA batteries (included) or universal AC adapter (sold separately)

Range (Relative mV):
±2000.0 mV

Resolution (Conductivity):
__

Resolution (Resistivity):
__

Resolution (TDS):
__

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature Accuracy:
±0.1°C

Temperature (English) Operating:
41°F to 113°F (ambient)

Temperature (Metric) Reference:
__

Temperature Range (English):
22.0°F to 221.0° F

Temperature Selection:
Manual or automatic with ATC temperature probe

Dimensions (L x W x H):
24cm x 10cm x 6.5cm (9.5 in. x 3.9 in. x 2.6 in.)

Weight (Metric):
0.5 kg

AC Adapter:
Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003)

Accuracy (mV):
±0.2 mV or ±0.05% of reading whichever is greater

Accuracy (Resistivity):
__

Accuracy (TDS):
__

Backlight Option:
Yes, selectable

Calibration Points:
1 point relative mV (RmV) mode, 1 point ORP mode

Calibration Points (pH):
1 to 5

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

Data Points:
5000 with date and time stamp

Display Type:
LCD Graphic, Backlit

Measurement Modes:
pH, mV, Relative mV, ORP with Temperature, Dissolved Oxygen (% Saturation), Dissolved Oxygen (mg/L with Temperature)

Range (mV):
±2000.0 mV

Range (Resistivity):
__

Range (TDS):
__

Temperature Range (Metric):
-5.0°C to +105.0°C

Isopotential Point:
7.000pH

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Power Rating:
__

Range (ORP):
±2000.0 mV

Relative Humidity Range:
5 to 85 %, non-condensing

Resolution (mV):
0.1mV

Resolution (Salinity):
__

Salinity Measurement Modes:
__

TDS Factor Range:
__

Temperature Compensation:
__

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Temperature Probe Calibration:
1 point temperature offset calibration

Temperature Resolution:
0.1°C, 0.1°F

Warranty:
3 Year Meter

Weight (English):