14-385-500LY

Thermo Scientific™ Evolution™ One UV-Vis Spectrophotometer, Trade-up Promotion

Manufacturer: Thermo Scientific™

Select a Size

Pack Size SKU Availability Price
Each of 1 14-385-500LY-Each-of-1 In Stock ₹ 6,84,480.00

14-385-500LY - Each of 1

₹ 6,84,480.00

In Stock

Quantity

1

Base Price: ₹ 6,84,480.00

GST (18%): ₹ 1,23,206.40

Total Price: ₹ 8,07,686.40

Baseline Flatness

±0.001 A, 200–800 nm, 1.0 nm SBW, smoothed

Detector Type

Silicon Photodiode

Light Source

Pulsed Xenon

Spectral Bandwidth

1 nm

Wavelength Range

190 to 1100 nm

Electrical Requirements

100/240 V, 50/60 Hz selected automatically, 150 W maximum

Noise

≤0.00015 A at 0 A, ≤0.00025 A at 1 A, ≤0.00050 A at 2 A, 260 nm, 1.0 nm SBW, RMS

Pharmacopoeia Compliance Testing

Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010 A; Stray Light: ≤1% T at 198 nm: KCI; ≤0.05% AT at 220 nm: Nal, Kl; Wavelength Accuracy: ±.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range; Wavelength Repeatability: ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line

Photometric Display

-0.3 to 4.0 A

Photometric Repeatability

1 A: ±0.0002 A

Scan Speed

<1 to 6000 nm/min. (Variable)

Wattage

150 W max.

Wavelength Data Interval

10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm

Weight (English)

32 lb.

Description

Evolution One UV-Vis Spectrophotometer

Dimensions (L x W x H)

593 x 475 x 266 mm (23.3 x 18.7 x 10.6 in.)

Product Line

Evolution One

Type

UV-Vis Spectrophotometer

Drift

<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup

Lamp Life

>5 years or longer if not using live signal

Optical Design

Double-beam with sample and reference cuvette positions Czerny-Turner Monochromator

Photometric Accuracy

1 A: ±0.004 A, 2 A: ±0.008 A, Measured at 440 nm using neutral density filters traceable to NIST

Photometric Range

>3.5 A

Scan Ordinate Modes

Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity

Warranty

Instrument (2 years), Lamp (3 years)

Wavelength Accuracy

±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)

Wavelength Repeatability

≤0.05 nm (546.1 nm mercury line, SD of 10 measurements)

Weight (Metric)

14.5 kg

Related Products

Img

Thermo Scientific™

14-385-503PM

--

Img

Thermo Scientific™

14-385-506LY

--

Img

Thermo Scientific™

14-385-355PM

--

Img

Thermo Scientific

S72304

--

Img

Thermo Scientific

S72306

--

Img

Thermo Scientific

S72307

--

Img

Thermo Scientific™

14-385-354

--

Img

Thermo Scientific™

14-385-355

--

Description

  • For routine to research analysis, this instrument series offers real innovations that provide enhanced usability and performance - without added complexity
  • With straightforward software, cutting-edge instrumentation and a wide selection of accessories, the Evolution One and One Plus UV-Vis Spectrophotometers work with you to perform experiments the way you want - for the results you need
  • Optimized Engineering Delivers Ultimate Performance: Double-beam geometry with fixed 1 nm or variable spectral bandwidth options Application Focused Beam Geometry (AFBG) technology enables the best performance from microcells, solid samples, and fiber optic probes (Evolution One Plus Only) Xenon flash lamp requires no warm-up time allowing instant measurements Meet chemical, materials science, or biological sampling and measurement needs with a broad range of accessories Insight Pro Software—Easy-to-learn, easy-to-use Reduce training time: Optimized user interface with prompting software defines clear step-by-step workflow and is easy to teach and learn Prevent costly sampling and measurement errors: Create dedicated workflows for complex assay and transform multi-step workflows into one simplified, easy-to-follow method suitable for any level of user with Customized User Environment (CUE) Always current: Whether it is user inputs or application requirements, or new regulations, Insight Pro Software is continuously improving with quick upgrades to deliver greater capabilities and efficiencies for your lab’s needs Accessories for all your Sampling Needs: Wide accessory selection with various temperature control options, sample changers, sippers and solid sampling devices complete your analysis Choice of Peltier Single Cell Holder or a Smart 8-Cell Peltier system for temperature control and sample monitoring from 0° to 100 °C Easy software integration gives you complete control of your measurements Regulatory/Quality Control Environments: To use the EvolutionOne/One Plus UV-Vis Spectrophotometers in a regulated or quality control environment, we offer a wide selection of compliance products and services to reduce implementation time and assure system performance
  • Evolution One/One Plus Security and Validator Bundles include: Evolution One or One Plus UV-Vis Spectrometer INSIGHT Pro with Security Software Validator for Insight Pro US Ltr or INTL A4 Paper Version Qualification Filter Kit for UV-Vis Evolution One/One Plus USP/EP Standards Pharma Bundles include: Evolution One or One Plus Spectrometer INSIGHT Pro with Security Software Validator for Insight Pro US Ltr or INTL A4 Paper Version USP and EP UV Standards Set USP and EP Visible Standards Set

Compare Similar Items

Show Difference

Img

Thermo Scientific™

14-385-500LY

--


Baseline Flatness:
±0.001 A, 200–800 nm, 1.0 nm SBW, smoothed

Detector Type:
Silicon Photodiode

Light Source:
Pulsed Xenon

Spectral Bandwidth:
1 nm

Wavelength Range:
190 to 1100 nm

Electrical Requirements:
100/240 V, 50/60 Hz selected automatically, 150 W maximum

Noise:
≤0.00015 A at 0 A, ≤0.00025 A at 1 A, ≤0.00050 A at 2 A, 260 nm, 1.0 nm SBW, RMS

Pharmacopoeia Compliance Testing:
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010 A; Stray Light: ≤1% T at 198 nm: KCI; ≤0.05% AT at 220 nm: Nal, Kl; Wavelength Accuracy: ±.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range; Wavelength Repeatability: ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line

Photometric Display:
-0.3 to 4.0 A

Photometric Repeatability:
1 A: ±0.0002 A

Scan Speed:
<1 to 6000 nm/min. (Variable)

Wattage:
150 W max.

Wavelength Data Interval:
10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm

Weight (English):
32 lb.

Description:
Evolution One UV-Vis Spectrophotometer

Dimensions (L x W x H):
593 x 475 x 266 mm (23.3 x 18.7 x 10.6 in.)

Product Line:
Evolution One

Type:
UV-Vis Spectrophotometer

Drift:
<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup

Lamp Life:
>5 years or longer if not using live signal

Optical Design:
Double-beam with sample and reference cuvette positions Czerny-Turner Monochromator

Photometric Accuracy:
1 A: ±0.004 A, 2 A: ±0.008 A, Measured at 440 nm using neutral density filters traceable to NIST

Photometric Range:
>3.5 A

Scan Ordinate Modes:
Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity

Warranty:
Instrument (2 years), Lamp (3 years)

Wavelength Accuracy:
±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)

Wavelength Repeatability:
≤0.05 nm (546.1 nm mercury line, SD of 10 measurements)

Weight (Metric):
14.5 kg

Img

Thermo Scientific™

14-385-503PM

--


Baseline Flatness:
±0.001 A, 200 to 800 nm, 1.0 nm SBW, smoothed

Detector Type:
Dual Silicon Photodiodes

Light Source:
Xenon Flash Lamp (>5 years typical, 3 years guaranteed)

Spectral Bandwidth:
Variable: 1 nm; 2 nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized

Wavelength Range:
190 to 1100 nm

Electrical Requirements:
100 to 240 V; 50 to 60 Hz, selected automatically, 150 W max.

Noise:
0A: ≤0.00015 A; 1A: ≤0.00025 A; 2A: ≤0.00050 A; 260 nm, 1.0 nm SBW, RMS

Pharmacopoeia Compliance Testing:
Photometric Accuracy (60 mg/L K2Cr2O7): ±0.010 A; Stray Light: ≤1%T at 198 nm: KCI; ≤0.05%AT at 220 nm: Nal, Kl; Wavelength Accuracy: ±.5 nm 541.9, 546.1 nm Hg emission lines, ±0.8 nm full range; Wavelength Repeatability: ≤0.05 nm, repetitive scanning of 546.1 nm Hg emission line

Photometric Display:
-0.3 to 4.0 A

Photometric Repeatability:
1 A: ±0.0002 A

Scan Speed:
<1 to 6000 nm/min, variable

Wattage:
150 W max.

Wavelength Data Interval:
__

Weight (English):
32 lb.

Description:
Evolution One Plus UV-Vis Spectrophotometer

Dimensions (L x W x H):
593 x 475 x 266 mm (23.3 x 18.7 x 10.6 in.)

Product Line:
__

Type:
__

Drift:
<0.0005 A/hr; 500 nm, 1.0 nm SBW, 1 hour warm-up

Lamp Life:
__

Optical Design:
Double beam with sample and reference cuvette positions Czerny-Turner Monochromator; Application Focused Beam Geometry; Czerny-Turner Monochromator

Photometric Accuracy:
__

Photometric Range:
>3.5 A

Scan Ordinate Modes:
Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs Factor, Intensity

Warranty:
__

Wavelength Accuracy:
±0.5 nm (541.9, 546.1 nm mercury lines); ±0.8 nm (full range 190 to 1100 nm)

Wavelength Repeatability:
≤0.05 nm (546.1 nm mercury line, SD of 10 measurements)

Weight (Metric):
14.5 kg

Img

Thermo Scientific™

14-385-506LY

--


Baseline Flatness:
±0.001 A (200 to 800 nm), 2.0 nm SBW, smoothed

Detector Type:
Silicon Photodiode

Light Source:
Pulsed Xenon

Spectral Bandwidth:
__

Wavelength Range:
190 to 1100 nm

Electrical Requirements:
100/240 V, 50/60 Hz

Noise:
<0.00018 A at 0 A; <0.00022 A at 1 A; <0.00050 A at 2 A, 500 nm, 2.0 nm SBW, RMS

Pharmacopoeia Compliance Testing:
Wavelength Accuracy: ±0.3 nm 190–900 nm; Wavelength Repeatability: SD 10 meas. <0.1 nm; Absorbance Accuracy: <±0.010 A at 1 A, <±0.010 A at 2 A; Absorbance Repeatability: ±0.0025 A @ 1 A

Photometric Display:
±6 A

Photometric Repeatability:
1 A: ±0.0025 A

Scan Speed:
Variable, up to 6000 nm/min.

Wattage:
__

Wavelength Data Interval:
10, 5, 2, 1, 0.5, 0.2, 0.1, 0.05 nm

Weight (English):
__

Description:
Evolution Pro UV-Vis Spectrophotometer

Dimensions (L x W x H):
__

Product Line:
__

Type:
UV-Vis Spectrophotometer

Drift:
<0.0005 A/hr., 500 nm, 2.0 nm SBW, 2 hr. warmup

Lamp Life:
>5 years or longer if not using live signal

Optical Design:
Modified Ebert, Double beam with sample and reference cuvette/accessory positions

Photometric Accuracy:
1 A: ±0.004 A,2 A: ±0.004 A, 3 A: ±0.006 A, Measured at 440 nm using neutral density filters traceable to NIST

Photometric Range:
>4 A

Scan Ordinate Modes:
Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, Log(1/R), Log(Abs), ABS × Factor, Intensity, 1st–4th Derivative

Warranty:
3-year Source Replacement Warranty

Wavelength Accuracy:
±0.20 nm (546.07 nm Hg emission line), ±0.30 nm, 190 to 900 nm

Wavelength Repeatability:
Standard deviation of 10 measurements <0.05 nm

Weight (Metric):
__

Img

Thermo Scientific™

14-385-527

--


Baseline Flatness:
__

Detector Type:
__

Light Source:
__

Spectral Bandwidth:
__

Wavelength Range:
__

Electrical Requirements:
__

Noise:
__

Pharmacopoeia Compliance Testing:
__

Photometric Display:
__

Photometric Repeatability:
__

Scan Speed:
__

Wattage:
__

Wavelength Data Interval:
__

Weight (English):
__

Description:
__

Dimensions (L x W x H):
__

Product Line:
__

Type:
Cell Holder

Drift:
__

Lamp Life:
__

Optical Design:
__

Photometric Accuracy:
__

Photometric Range:
__

Scan Ordinate Modes:
__

Warranty:
__

Wavelength Accuracy:
__

Wavelength Repeatability:
__

Weight (Metric):
__