PI23325

Thermo Scientific™ Easy-Titer™ Human IgG (gamma chain) Assay Kit

Manufacturer: Thermo Scientific™

Select a Size

Pack Size SKU Availability Price
Each of 1 PI23325-Each-of-1 In Stock ₹ 63,271.62

PI23325 - Each of 1

₹ 63,271.62

In Stock

Quantity

1

Base Price: ₹ 63,271.62

GST (18%): ₹ 11,388.892

Total Price: ₹ 74,660.512

Description

Easy-Titer Human IgG (Gamma Chain) Assay Kit

Target Specificity

Target-specific

For Use With (Equipment)

Spectrophotometer, Microplate Reader

Assay

Protein Quantitation Assay, Isotyping Assay, Immunoassay

Content And Storage

Sufficient For: 96 total tests (including 9 standards per use)• Goat Anti-Human IgG (gamma chain) Sensitized Polystyrene Beads, 2mL• Easy-Titer Dilution Buffer, 30 mL• Easy-Titer Blocking Buffer, 15 mLStore at 4°C (do not freeze).

Quantity

96 tests

For Use With (Application)

Solution-based Detection, Absorbance

Product Line

Easy-Titer™

Detection Method

Colorimetric

Related Products

Img

Thermo Scientific™

PI23315

--

Img

Thermo Scientific™

PI23310

--

Img

Thermo Scientific™

PI23305

--

Img

Thermo Scientific™

PI23300

--

Img

Thermo Scientific™

37-503

--

Img

Thermo Scientific™

PI44916

--

Img

Thermo Scientific™

PI44600

--

Img

Thermo Scientific™

PI77667

--

Description

  • Thermo Scientific™ Easy-Titer Antibody Assay Kits enable accurate determination of antibody concentration in serum and culture supernatant, and include kits specific for mouse IgG, rabbit IgG, human IgG (H+L), human IgG (Fc), or human IgM
  • These kits include antibody-sensitized microspheres to measure the specific concentration of mouse, rabbit and human antibodies by an easy and rapid micro-agglutination technique using standard microplates and UV-Vis plate reader (spectrophotometer)
  • Each kit is specific for a particular species and class of immunoglobulin and, unlike total protein assays, can specifically measure the concentration of target antibody in samples (e.g., serum, plasma, culture supernatant) that contain other proteins
  • The kits are extremely sensitive, requiring very small sample volumes
  • Antibody concentration is determined from the assay response (absorbance) by comparison to a standard curve prepared using dilutions of a known antibody sample (sold separately)
  • Highlights: Kits for five popular targets – choose a kit specific for a particular species and class of immunoglobulin; no cross-reaction with other species and classes of the target antibody Antibody-based specificity – measure concentration of target antibody in a sample, not just total protein; no need to purify antibody to assess its concentration Faster and easier than ELISA – three-component, homogenous assay; 10 minutes total incubation time No special equipment needed – uses standard vortex mixer, pipetter, 96-well microplate, plate shaker and reader (measure absorbance at 340nm or 400nm) Sensitive – assay range (standard curve) 8 to 500ng/mL; requires starting sample of at least 300ng/mL Reproducible – coefficient of variation less than 5%; error depends on dilution and pipetting technique Antibody standards sold separately – use any antibody standard with proper target identity and known concentration (greater than 10μg/mL) Easy-Titer Antibody Assays are faster and easier than ELISA: 1
  • Prepare standards (5 to 500ng/mL) by diluting purified antibody in Kit Dilution Buffer 2
  • Prepare samples by diluting at least 20-fold in Dilution Buffer to within assay range (8 to 500ng/mL)
  • 3
  • Vortex vial of microsphere beads to create homogeneous suspension
  • 4
  • Pipette 20μL of bead suspension and 20μL of each sample and standard into 96-well microplate wells
  • 5
  • Incubate microplate for 5 minutes with vigorous mixing
  • 6
  • Add 100μL of Kit Blocking Reagent
  • 7
  • Incubate microplate for 5 minutes with vigorous mixing
  • 8
  • Measure absorbance on standard plate reader (340nm or 405nm)
  • 9
  • Plot standard curve and interpolate samples to determine concentration
  • Includes: Each kit contains target-specific IgG sensitized microspheres, dilution buffer and blocking buffer

Compare Similar Items

Show Difference

Img

Thermo Scientific™

PI23325

--


Description:
Easy-Titer Human IgG (Gamma Chain) Assay Kit

Target Specificity:
Target-specific

For Use With (Equipment):
Spectrophotometer, Microplate Reader

Assay:
Protein Quantitation Assay, Isotyping Assay, Immunoassay

Content And Storage:
Sufficient For: 96 total tests (including 9 standards per use)• Goat Anti-Human IgG (gamma chain) Sensitized Polystyrene Beads, 2mL• Easy-Titer Dilution Buffer, 30 mL• Easy-Titer Blocking Buffer, 15 mLStore at 4°C (do not freeze).

Quantity:
96 tests

For Use With (Application):
Solution-based Detection, Absorbance

Product Line:
Easy-Titer™

Detection Method:
Colorimetric

Img

Thermo Scientific™

PI23456

--


Description:
Controlled Protein-Protein Crosslinking Kit

Target Specificity:
__

For Use With (Equipment):
__

Assay:
__

Content And Storage:
Sufficient For: One conjugation with two purified proteins (up to 5 mg each)• Sulfo-SMCC Crosslinking Agent, 2 mg• Activation/Conjugation Buffer (10X), 20 mL• PBS packs (each makes 500mL), 2 packs• 2-Mercaptoethylamine-HCl, 6 mg• Immobilized-Reductant, 0.2 mL• SATA, 2 mg• Dimethylformamide (DMF), 1 mL• Hydroxylamine-HCl, 5 mg• Dextran Desalting Column, 2 x 10 mL• Column Extender, 2 ea.• Cysteine-HCl, 20 mg• Ellman's Reagent, 2 mgStore at 4°C.

Quantity:
1 Reaction

For Use With (Application):
__

Product Line:
Pierce™

Detection Method:
__

Img

Thermo Scientific™

PI23460

--


Description:
__

Target Specificity:
__

For Use With (Equipment):
__

Assay:
__

Content And Storage:
Sufficient For: One modification experiment with 0.5 to 5 mg of purified protein• SATA, 2 mg• Hydroxylamine·HCl, 5 mg• Conjugation Buffer Stock (10X), 20 mL• PBS pack (makes 500 mL), 1 pack• Dimethylformamide (DMF), 1 mL• Dextran Desalting Column, 1 x 5 mL• Column Extender, 1• Ellman's Reagent (DTNB), 2 mg• Cysteine·HCl, 20 mgStore at 4°C.

Quantity:
1 Reaction

For Use With (Application):
__

Product Line:
Pierce™

Detection Method:
__

Img

Thermo Scientific™

PI23500

--


Description:
__

Target Specificity:
__

For Use With (Equipment):
__

Assay:
__

Content And Storage:
Sufficient For: 10 mini gel or blot experiments with a biotinylated-protein probe• Streptavidin-HRP Conjugate, 0.1 mg• Dilution Buffer (10X), 50 mL• PBS Packs (each makes 500 mL), 17 packs• Luminol Enhancer, 55 mL• Stable Peroxide Buffer, 55 mL• Surfact-Amps 20 Detergent Solution, 6 x 10 mL• Pre-Cut Cellophane, 10 sheetsStore kit at 4°C.

Quantity:
220 mL

For Use With (Application):
__

Product Line:
Pierce™

Detection Method:
Chemiluminescence