4532169

Thermo Scientific™ Pierce™ Renilla Luciferase Glow Assay Kit

Obtain bright and stable bioluminescence signal (half-life approx. 3 hour) in the presence of Renilla luciferase reporters.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Type

Assay Kit

Assay

Reporter Enzyme, Luciferase Reporter Assay

Detection Method

Bioluminescence

Format

384-well plate, 96-well plate

Substrate Properties

Chemical Substrate

Substrate Type

Luciferase Substrate

Substrate

Coelenterazine

Target

Luciferase, Green Renilla Luciferase

Compatible Cells

Mammalian Cells

For Use With (Equipment)

Luminometer (Microplate)

Label Type

Enzyme Labeled

Technique

Enhanced Chemiluminescence

Product Line

Pierce™

Related Products

Img

Fischer Scientific

4532168

Assay regulatory element transcript...

Img

Fischer Scientific

4532162

Assay regulatory element transcript...

Img

Fischer Scientific

4532166

Obtain bright and stable biolumines...

Img

Fischer Scientific

4532170

Simultaneously detect intracellular...

Img

Fischer Scientific

4937579

Measure TurboLuc™16 (Tluc16) lucife...

Img

Fischer Scientific

4532171

Assay regulatory element transcript...

Img

Fischer Scientific

4532163

Simultaneously detect intracellular...

Img

Fischer Scientific

4532172

Obtain bright and stable biolumines...

Description

  • Thermo Scientific™ Pierce Renilla Luciferase Glow Assay Kit provides an extremely bright and stable bioluminescence signal (half-life approx
  • 3 hours), especially in the presence of Green Renilla luciferase reporter
  • This Pierce Luciferase Glow Assay Kit contains reagents for measuring the activity of Renilla luciferase in cell lysates
  • In the presence of luciferase, the glow reagent provides stable bioluminescent signal and is highly suited for luminometers without injectors or for batch processing of samples
  • The light output generated by the luciferase reaction can be correlated with the amount of luciferase protein produced which in turn is proportional to the promoter activity driving the luciferase expression
  • The glow assay reagents were optimized for best results with Thermo Scientific Green Renilla Luc Plasmids; however, this glow kit may be used to detect the activity of other Renilla luciferase derivatives that use coelenterazine as a substrate
  • Highlights: Sensitive – highly sensitive detection of Green Renilla luciferase activity Stable – increased signal stability compared to flash assays Simple – does not require a luminometer with injectors Compatible – assay reagents compatible with other Renilla luciferases Automation-friendly – amenable to high throughput assays Convenient – contains a universal cell lysis buffer and optimized glow assay reagent Safe – allows one to perform non-radioactive assays Includes: Cell lysis buffer, reaction buffer and substrate Requires: Renilla luciferase and luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan™ Ascent and Varioskan™ Flash Microplate Readers Recommended for: Promoter studies for analyzing cis - regulatory elements and trans -acting factors; Drug screening; siRNA and miRNA screening; Multiplexed assays to study off-target effects; Protein localization reporter assays; Signal transduction pathway analysis; RNA splicing studies

Compare Similar Items

Show Difference

Img

Fischer Scientific

4532169

Obtain bright and stable biolumines...


Type:
Assay Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
Coelenterazine

Target:
Luciferase, Green Renilla Luciferase

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Product Line:
Pierce™

Img

Fischer Scientific

4532170

Simultaneously detect intracellular...


Type:
Assay Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
Coelenterazine, D-Luciferin

Target:
Luciferase, Firefly Luciferase, Green Renilla Luciferase

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Product Line:
Pierce™

Img

Fischer Scientific

4532171

Assay regulatory element transcript...


Type:
Assay Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
D-Luciferin

Target:
Luciferase, Firefly Luciferase

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Product Line:
Pierce™

Img

Fischer Scientific

4532172

Obtain bright and stable biolumines...


Type:
Assay Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Substrate:
D-Luciferin

Target:
Luciferase, Firefly Luciferase

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Product Line:
__