4701929

Thermo Scientific™ Pierce™ Firefly Luc One-Step Glow Assay Kit

Perform firefly luciferase assays in high-throughput screening applications.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Type

Assay Kit

Assay

Reporter Enzyme, Luciferase Reporter Assay

Detection Method

Bioluminescence

Format

384-well plate, 96-well plate

Substrate Properties

Chemical Substrate

Substrate Type

Luciferase Substrate

Target

Luciferase, Firefly Luciferase, Cypridina Luciferase

Compatible Cells

Mammalian Cells

For Use With (Equipment)

Luminometer (Microplate)

Label Type

Enzyme Labeled

Technique

Enhanced Chemiluminescence

Substrate

D-Luciferin

Related Products

Img

Fischer Scientific

4532172

Obtain bright and stable biolumines...

Img

Fischer Scientific

4532171

Assay regulatory element transcript...

Img

Fischer Scientific

4532163

Simultaneously detect intracellular...

Img

Fischer Scientific

4532170

Simultaneously detect intracellular...

Img

Fischer Scientific

4532161

Simultaneously detect intracellular...

Img

Fischer Scientific

4532159

Assay regulatory element transcript...

Img

Fischer Scientific

4532160

Obtain bright and stable biolumines...

Img

Fischer Scientific

4937579

Measure TurboLuc™16 (Tluc16) lucife...

Description

  • The Thermo Scientific Pierce Firefly One-Step Luc Glow Assay Kit measures firefly luciferase activity in mammalian cell culture using a single reagent-addition step, making it ideal for high-throughput screening (HTS) applications
  • This glow-type luciferase assay kit is designed for use with cultured mammalian cells that are transfected with vectors expressing the appropriate firefly luciferase reporter enzyme
  • Several features make the kit especially suitable for luminometers without injectors and for high-throughput screening (HTS) applications
  • The convenient, one-step, homogenous protocol minimizes handling steps to support the use of automation
  • Simply combine the supplied substrate solution and assay buffer to make a single working solution, and then add it to microplate wells containing the transfected, treated cells
  • The stable signal output (glow) of this system provides flexibility with regard to incubation time
  • When used with Thermo Scientific Firefly Luc Plasmids, the kit provides a highly sensitive bioluminescent reporter assay system for the detection of promoter or pathway activity
  • Highlights: Sensitive - highly sensitive detection of firefly luciferase activity Convenient - one-step, mix-and-read protocol; no additional reagents required Stable - increased signal half-life and stability compared to flash assays Simple - does not require a luminometer with injectors Automation-friendly - amenable to high throughput assays Includes: Assay buffer and substrate solution (100X) Requires: Firefly luciferase and luminometer or other instrument capable of monitoring luminescence, such as Thermo Scientific Luminoskan Ascent and Varioskan Flash Microplate Readers
  • Applications: Promoter studies for analyzing cis- and trans-acting regulatory elements Drug screening siRNA and miRNA screening Multiplexed assays to study off-target effects Protein localization reporter assays Signal transduction pathway analysis Product Details: Firefly luciferase is a 62kDa protein produced in nature by several species of the Lampyridae family of beetles, which includes the genera Photinus and Luciola
  • Thermo Scientific Red Firefly Luciferase has an emission range of 560-700nm (λmax = 613nm)
  • Bioluminescent signal from firefly luciferase originates from the oxidation of D-Luciferin
  • Light output captured using a luminometer can be correlated with the amount of firefly luciferase protein produced and used to determine the activity of the promoter driving firefly luciferase expression
  • Firefly luciferase bioluminescence provides researchers with a non-radioactive assay for measuring transcriptional activity of regulatory elements
  • Firefly luciferase reporter activity can be used to determine promoter activity, to study upstream pathway activity in the cell, or to determine effect of activators or inhibitors.

Compare Similar Items

Show Difference

Img

Fischer Scientific

4701929

Perform firefly luciferase assays i...


Type:
Assay Kit

Assay:
Reporter Enzyme, Luciferase Reporter Assay

Detection Method:
Bioluminescence

Format:
384-well plate, 96-well plate

Substrate Properties:
Chemical Substrate

Substrate Type:
Luciferase Substrate

Target:
Luciferase, Firefly Luciferase, Cypridina Luciferase

Compatible Cells:
Mammalian Cells

For Use With (Equipment):
Luminometer (Microplate)

Label Type:
Enzyme Labeled

Technique:
Enhanced Chemiluminescence

Substrate:
D-Luciferin

Img

Sigma Aldrich

470198

70%...


Type:
__

Assay:
70%

Detection Method:
__

Format:
__

Substrate Properties:
__

Substrate Type:
__

Target:
__

Compatible Cells:
__

For Use With (Equipment):
__

Label Type:
__

Technique:
__

Substrate:
__

Img

Sigma Aldrich

470201

≥98%...


Type:
__

Assay:
≥98%

Detection Method:
__

Format:
__

Substrate Properties:
__

Substrate Type:
__

Target:
__

Compatible Cells:
__

For Use With (Equipment):
__

Label Type:
__

Technique:
__

Substrate:
__

Img

Fischer Scientific

4702171

Filter element replacement parts fo...


Type:
__

Assay:
__

Detection Method:
__

Format:
__

Substrate Properties:
__

Substrate Type:
__

Target:
__

Compatible Cells:
__

For Use With (Equipment):
CAB 15 or 30 cfm Breathing Air Filtration System

Label Type:
__

Technique:
__

Substrate:
__