14-385-445

Thermo Scientific™ GENESYS™ 20 Visible Spectrophotometer

Manufacturer: Thermo Scientific™

The price for this product is unavailable. Please request a quote

Depth (English)

13 in.

Description

GENESYS 20 without printerIn Germany, France, or Spain, use Catalog #4001-03

Display

20 character, 2 line LCD

Product Line

GENESYS 20

Type

Visible Spectrophotometer without Printer

Drift

0.003 A/hr.

Height (English)

7 in.

Hertz

50/60 Hz

Interface

RS-232-C (serial)

Noise

≤0.001A at 0A ≤0.004A at 2A, 500 nm

Photometric Accuracy

±0.003 A from 0.0 to 0.3A1.0% from 0.301 A to 2.5 A, NIST 930D filters

Photometric Readout

Absorbance, %Transmittance, Concentration

Warranty

1 Year

Weight (English)

10 lb.

Width (English)

12 in.

Depth (Metric)

33 cm

Detector Type

Silicon Photodiode

Light Source

Tungsten Halogen

Spectral Bandwidth

≤8 nm

Wavelength Range

325 to 1100 nm

Electrical Requirements

Selected automatically, 120 V

Height (Metric)

19 cm

Includes

10mm cell holder; dust cover; U.S. power cord

Lamp Life

1000 hrs.

Optical Design

Single Beam

Photometric Range

-0.1-2.5A; 0-125%T, 0-1999C

Stray Light

<0.1%T at 340 nm and 400 nm

Wavelength Accuracy

±2.0 nm

Weight (Metric)

4.5 kg

Width (Metric)

30 cm

Related Products

Img

Thermo Scientific™

S28434

--

Img

Thermo Scientific™

14-385-491

--

Img

Lovibond™

15-398-350

--

Img

Lovibond™

15-398-351

--

Img

Thermo Scientific™

14-380-442PM

--

Img

Thermo Scientific

S28454

--

Img

Thermo Scientific

S72305

--

Img

Thermo Scientific

S72303

--

Description

  • Thermo Scientific™ GENESYS 20 is a compact, low-cost, easy-to-use, Visible spectrophotometer designed for classrooms and routine laboratories
  • A simple, 4-step measurement process and optional VISION lite ™ software make the GENESYS 20 the most cost-effective, visible spectrophotometer available
  • Multiple purpose capabilities allow you to measure a wide range of analytes
  • Precise and Reliable Compact footprint provides a space-saving, convenient system‚ Intuitive keyboard with integrated controls and LCD display Routine measurements require just a few keystrokes Direct measurement of routine absorbance or transmittance data Concentration mode for single point standard or factor-based quantitative analysis Optional holders for test tubes and long path cells to 50mm User-selectable choice of five languages (English, French, German, Spanish, Italian) Bidirectional RS-232-C interface Low Cost of Ownership Cleanable, chemical-resistant surfaces and rugged design withstands harsh laboratory environments Few moving parts; virtually maintenance-free operation Choose instrument with or without integral printer Includes: 10mm cell holder, dust cover, and U.S
  • power cord
  • Note: Fisher Service Division offers several types of service agreements for the equipment featured here
  • For details on these agreements, equipment repairs, and calibration services, see the front of the catalog
  • For immediate assistance, call 1-800-395-5442.

Compare Similar Items

Show Difference

Img

Thermo Scientific™

14-385-445

--


Depth (English):
13 in.

Description:
GENESYS 20 without printerIn Germany, France, or Spain, use Catalog #4001-03

Display:
20 character, 2 line LCD

Product Line:
GENESYS 20

Type:
Visible Spectrophotometer without Printer

Drift:
0.003 A/hr.

Height (English):
7 in.

Hertz:
50/60 Hz

Interface:
RS-232-C (serial)

Noise:
≤0.001A at 0A ≤0.004A at 2A, 500 nm

Photometric Accuracy:
±0.003 A from 0.0 to 0.3A1.0% from 0.301 A to 2.5 A, NIST 930D filters

Photometric Readout:
Absorbance, %Transmittance, Concentration

Warranty:
1 Year

Weight (English):
10 lb.

Width (English):
12 in.

Depth (Metric):
33 cm

Detector Type:
Silicon Photodiode

Light Source:
Tungsten Halogen

Spectral Bandwidth:
≤8 nm

Wavelength Range:
325 to 1100 nm

Electrical Requirements:
Selected automatically, 120 V

Height (Metric):
19 cm

Includes:
10mm cell holder; dust cover; U.S. power cord

Lamp Life:
1000 hrs.

Optical Design:
Single Beam

Photometric Range:
-0.1-2.5A; 0-125%T, 0-1999C

Stray Light:
<0.1%T at 340 nm and 400 nm

Wavelength Accuracy:
±2.0 nm

Weight (Metric):
4.5 kg

Width (Metric):
30 cm

Img

Thermo Scientific™

14-385-448

--


Depth (English):
__

Description:
__

Display:
__

Product Line:
__

Type:
Cell Holder

Drift:
__

Height (English):
__

Hertz:
__

Interface:
__

Noise:
__

Photometric Accuracy:
__

Photometric Readout:
__

Warranty:
__

Weight (English):
__

Width (English):
__

Depth (Metric):
__

Detector Type:
__

Light Source:
__

Spectral Bandwidth:
__

Wavelength Range:
__

Electrical Requirements:
__

Height (Metric):
__

Includes:
__

Lamp Life:
__

Optical Design:
__

Photometric Range:
__

Stray Light:
__

Wavelength Accuracy:
__

Weight (Metric):
__

Width (Metric):
__

Img

Thermo Scientific™

14-385-450

--


Depth (English):
__

Description:
__

Display:
__

Product Line:
__

Type:
Cylindrical Cell Holder

Drift:
__

Height (English):
__

Hertz:
__

Interface:
__

Noise:
__

Photometric Accuracy:
__

Photometric Readout:
__

Warranty:
__

Weight (English):
__

Width (English):
__

Depth (Metric):
__

Detector Type:
__

Light Source:
__

Spectral Bandwidth:
__

Wavelength Range:
__

Electrical Requirements:
__

Height (Metric):
__

Includes:
__

Lamp Life:
__

Optical Design:
__

Photometric Range:
__

Stray Light:
__

Wavelength Accuracy:
__

Weight (Metric):
__

Width (Metric):
__

Img

Thermo Scientific™

14-385-451

--


Depth (English):
__

Description:
__

Display:
__

Product Line:
__

Type:
Cell Holder

Drift:
__

Height (English):
__

Hertz:
__

Interface:
__

Noise:
__

Photometric Accuracy:
__

Photometric Readout:
__

Warranty:
__

Weight (English):
__

Width (English):
__

Depth (Metric):
__

Detector Type:
__

Light Source:
__

Spectral Bandwidth:
__

Wavelength Range:
__

Electrical Requirements:
__

Height (Metric):
__

Includes:
__

Lamp Life:
__

Optical Design:
__

Photometric Range:
__

Stray Light:
__

Wavelength Accuracy:
__

Weight (Metric):
__

Width (Metric):
__