Lovibond™ XD7500 Water Quality Spectrophotometer

Manufacturer: Lovibond™

Select a Size

Pack Size SKU Availability Price
Each of 1 15-398-351-Each-of-1 In Stock ₹ 11,03,125.08

15-398-351 - Each of 1

₹ 11,03,125.08

In Stock

Quantity

1

Base Price: ₹ 11,03,125.08

GST (18%): ₹ 1,98,562.514

Total Price: ₹ 13,01,687.594

Display

Color Graphic Display

Wavelength Selection

Automatic

Drift

<0.005 Abs per hour after 15 minutes heat up time

Lamp Life

500 Million flashes

Parameter

Pre-programmed with over 150 analytical methods that cover a wide variety of applications and industries

Photometric Range

-3.3 to +3.3 Abs

Range

Scan Range: 190 to 1100 nm

Sample Size

Method Dependant

Stray Light

<0.1 % Transmission at 340 and 408 nm

Light Source

Xenon Flash

Disposable

Reusable

Interface

Ethernet, USB B, USB A for External Memory, Keypad, Barcode-Scanner, PCL Compatible Printer

Optical Design

Grid monochromator with reference beam and beam splitter after exit slit

Photometric Linearity

<1% up to 2.0 Abs between 340 to 900 nm

Photometric Repeatability

0.003 Abs below 0.6 Abs ; 0.5 % from 0.6 to 2.0 Abs

Reagent Form

Liquid, Tablet or Powder Pack

Scan Speed

700 to 2000 nm/min.

Wavelength Repeatability

±1 nm on all Holmium peaks

Related Products

Img

Lovibond™

15-398-350

--

Img

Thermo Scientific™

S28434

--

Img

Thermo Scientific™

14-385-491

--

Img

Thermo Scientific™

14-385-445

--

Img

Thermo Scientific™

14-380-442PM

--

Img

Thermo Scientific

S28454

--

Img

Thermo Scientific

S72304

--

Img

Thermo Scientific

S72305

--

Description

  • UV-VIS wavelength spectrum supports a wide variety of applications Pre-programed with over 150 Lovibond™ testing methods Integrated smart features save time and eliminate chances of errors User security and data protection features The XD 7500 Spectrophotometer combines a state-of-the-art optical system with ease of use and flexibility for a wide range of testing applications
  • The user interface incorporates a variety of features, such as automatic test recognition and cuvette type detection, that are designed to prevent measurement errors, ensuring the accuracy of displayed results and save time
  • In addition to the standard range of Lovibond™ colorimetric testing methods, this instrument will provide users with the full range of functions that is required from a spectrophotometer including: Measurement of transmission and absorbance; Scanning of spectral data; Recording of kinetic measurements; The creation of measuring methods based on up to ten wavelengths with various mathematical operations; and the ability to test a variety of new methods that require the UV range
  • Method Detection Made Easy Avoid measurement errors due to accidently selecting the incorrect method and reagent combination
  • Tube Test reagents are labeled with a barcode for automatic test recognition while other test methods can be scanned with the optional barcode reader to bring users directly to the correct testing mode
  • Automatic Cuvette Type Detection Just like using the incorrect testing method and reagent combination can easily lead to measurement errors, using the wrong sample cell associated with a method also leads to incorrect results
  • Each Lovibond™ water quality testing method is associated with a type of sample cell - insert the incorrect one, and the instrument will stop the measurement process
  • Preprogrammed Testing Methods The XD Series is pre-programmed with over 150 testing methods that use Lovibond™ water quality reagents, making it an easy and efficient solution to implement in your laboratory
  • Don’t waste time developing calibration curves or making your own testing solutions
  • Easy Access to new testing parameters and ranges Never have an outdated instrument again! As additional test methods become available, the new software update can be download from lovibond.com and installed on the instrument using a USB stick or PC connection
  • User Security for Data Protection It’s easy to create up to three different user levels with password protection
  • Each user account can be assigned a level of access to ensure users only have access to what they need
  • Set Testing & Maintenance Parameters The XD Series supports analytical quality assurance procedures, including the ability to set measurement tolerances and reminders for calibration protocols
  • Intuitive User Interface Easy-to-read, full-color display with softkeys and integrated keyboard
  • Users can output data to a PCL-3 compatible printer, USB drive or via an Ethernet connection
  • Comprehensive support of analytical quality assurance Through a variety of smart instrument features and optional accessories, users will feel confident their results are correct
  • The instrument performs a comprehensive self-check each time it is powered on, and periodically performs status checks while the instrument remains on
  • Additionally, a variety of primary ValidCheck™ standards are available for method validation.

Compare Similar Items

Show Difference

Img

Lovibond™

15-398-351

--


Display:
Color Graphic Display

Wavelength Selection:
Automatic

Drift:
<0.005 Abs per hour after 15 minutes heat up time

Lamp Life:
500 Million flashes

Parameter:
Pre-programmed with over 150 analytical methods that cover a wide variety of applications and industries

Photometric Range:
-3.3 to +3.3 Abs

Range:
Scan Range: 190 to 1100 nm

Sample Size:
Method Dependant

Stray Light:
<0.1 % Transmission at 340 and 408 nm

Light Source:
Xenon Flash

Disposable:
Reusable

Interface:
Ethernet, USB B, USB A for External Memory, Keypad, Barcode-Scanner, PCL Compatible Printer

Optical Design:
Grid monochromator with reference beam and beam splitter after exit slit

Photometric Linearity:
<1% up to 2.0 Abs between 340 to 900 nm

Photometric Repeatability:
0.003 Abs below 0.6 Abs ; 0.5 % from 0.6 to 2.0 Abs

Reagent Form:
Liquid, Tablet or Powder Pack

Scan Speed:
700 to 2000 nm/min.

Wavelength Repeatability:
±1 nm on all Holmium peaks

Img

Lovibond™

15-398-353

--


Display:
Touchscreen

Wavelength Selection:
__

Drift:
__

Lamp Life:
5 years, more than 3 million measurements

Parameter:
__

Photometric Range:
__

Range:
__

Sample Size:
__

Stray Light:
__

Light Source:
__

Disposable:
__

Interface:
__

Optical Design:
__

Photometric Linearity:
__

Photometric Repeatability:
__

Reagent Form:
__

Scan Speed:
__

Wavelength Repeatability:
__

Img

Lovibond™

15-398-354

--


Display:
Touchscreen

Wavelength Selection:
__

Drift:
__

Lamp Life:
__

Parameter:
__

Photometric Range:
__

Range:
__

Sample Size:
__

Stray Light:
__

Light Source:
__

Disposable:
__

Interface:
__

Optical Design:
__

Photometric Linearity:
__

Photometric Repeatability:
__

Reagent Form:
__

Scan Speed:
__

Wavelength Repeatability:
__

Img

Lovibond™

15-398-355

--


Display:
Touchscreen

Wavelength Selection:
__

Drift:
__

Lamp Life:
__

Parameter:
__

Photometric Range:
__

Range:
__

Sample Size:
__

Stray Light:
__

Light Source:
__

Disposable:
Reusable

Interface:
__

Optical Design:
__

Photometric Linearity:
__

Photometric Repeatability:
__

Reagent Form:
__

Scan Speed:
__

Wavelength Repeatability:
__